Poly(allyl diglycol carbonate), ADC (CR-39) ADC (CR-39)

Poly(allyl diglycol carbonate), a crosslinked thermoset of the monomer diethylene glycol bis(allyl carbonate), C12H18O7 (monomer) · CAS 25656-90-0 for the polymer (Wikipedia infobox); 142-22-3 for the monomer (Wikipedia infobox)

Poly(allyl diglycol carbonate), sold as CR-39, is a clear, rigid thermoset made by polymerising the liquid monomer allyl diglycol carbonate (C12H18O7).

8 sources · Updated 2026-10-20 · CC BY 4.0

Evidence level

5 of 5

Flown or field-proven

Let light through

91 % light transmittance

Bend light well

1.498 refractive index

Detect particles

3 % energy resolution for 2.9 MeV protons

Stay clear in heat

100 °C continuous use

Recipe, share of the weight

  • ADC Molar mass 274.2700 g/mol (NASA Table IV)Diethylene glycol bis(allyl carbonate), allyl diglycol carbonate
  • IPP Share not readDiisopropyl peroxydicarbonate

Best for

Light, clear optical parts and track detectors: 1.498 refractive index and about half the weight of glass (Wikipedia)

Weakest at

Atomic oxygen in low Earth orbit (erosion yield above 6.80e-24 cm3/atom on MISSE 2) and UV, which changes its optical absorption and etch behaviour

Risk at a glance

  • People Low. Monomer hazardous, polymer not classified
  • If it fails Severe. Atomic oxygen erosion in low Earth orbit
  • Corrosion Severe. The erosion yield is above 6.80e-24 cm3/atom, so the sample eroded through before the end of the exposure.

Quick facts: ADC (CR-39)

Key properties of ADC (CR-39)
PropertyValueBasis
Density1.14 to 1.32 g/cm³3 sourced values across conditions
Thermal expansion (CTE)117 ppm/K1 sourced value
Melting point-4 °C1 sourced value
Maximum service temperature100 °C1 sourced value

What is the density of Poly, ADC (CR-39)?

Poly, ADC (CR-39) has a density of 1.14 to 1.32 g/cm³. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the coefficient of thermal expansion of Poly, ADC (CR-39)?

Poly, ADC (CR-39) has a coefficient of thermal expansion of 117 ppm/K. The source and test conditions are listed in the properties table on this page.

What is the melting point of Poly, ADC (CR-39)?

Poly, ADC (CR-39) has a melting point of -4 °C. The source and test conditions are listed in the properties table on this page.

What is the maximum service temperature of Poly, ADC (CR-39)?

Poly, ADC (CR-39) has a maximum service temperature of 100 °C. The source and test conditions are listed in the properties table on this page.

What is Poly, ADC (CR-39) used for?

Uses recorded in the sources include Eyeglass and sunglass lenses; Solid-state nuclear track detector (dosimetry, not shielding); Space exposure test sample (MISSE 2, flight).

Why it exists

CR-39 is a clear, light plastic: its refractive index is 1.498, its specific gravity is 1.32 and it transmits 91 % of light in the patent comparison. Its heat resistance is 91 °C, and it weighs about half as much as glass. It is also a reliable track detector, with energy resolution of 3 % for 2.9 MeV protons.

Where it's used

Eyeglass lenses

CR-39 lenses weigh about half as much as glass, and the first were made in 1947.

Track detectors

CR-39 records alpha particles, neutrons, protons and radon, and is etched in sodium hydroxide to reveal tracks.

Space test

ADC (CR-39) flew on the MISSE 2 PEACE tray on the ISS from 2001 to 2005, with an erosion yield greater than 6.80e-24 cm3/atom.

Recipe

Poly(allyl diglycol carbonate), a crosslinked thermoset of the monomer diethylene glycol bis(allyl carbonate), C12H18O7 (monomer)

Poly(allyl diglycol carbonate) is made by polymerising the liquid monomer diethylene glycol bis(allyl carbonate), C12H18O7 (NASA Table IV; Wikipedia). The monomer is cured with a peroxide initiator, diisopropyl peroxydicarbonate, over about 18 hours (patent Table 1). The allyl groups crosslink, which makes the polymer a thermoset with no melting point.

What ADC (CR-39) is made of
IngredientShare of the weightWhat it does
Diethylene glycol bis(allyl carbonate), allyl diglycol carbonate ADC Molar mass 274.2700 g/mol (NASA Table IV) Monomer. Its allyl groups crosslink on polymerisation.
Diisopropyl peroxydicarbonate IPP Share not read Initiator for the radical cure. Benzoyl peroxide is an alternative that gives a higher yellowness index (Wikipedia).

Weight shares are as printed in the sources.

What it can do

Let light through

91 % light transmittance

measured

The CR-39 comparative example in the patent transmits 91 % of light, and a commercial 2 mm ADC plate transmits 92 %.

Bend light well

1.498 refractive index

measured

The cured plastic has a refractive index of 1.498, close to the value for crown glass, per Wikipedia.

Detect particles

3 % energy resolution for 2.9 MeV protons

measured

The track-detector study reports 3 % energy resolution for 2.9 MeV protons and 4 % for 3.15 MeV.

Stay clear in heat

100 °C continuous use

measured

CR-39 is rated for continuous use up to 100 °C, and up to one hour at 130 °C per Wikipedia (citation needed).

How it compares

The patent comparison puts CR-39 at 91 % light transmittance and a 1.498 refractive index. These are single comparative examples, so they are examples rather than a ranking against other optical plastics.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementADC (CR-39)PC
Capacity and energy
Energy resolution, 2.9 MeV protons3 %16no data
Thermal behavior and safety
Melting point, monomer ADCPrinted in the Wikipedia infobox for the monomer-4 °Cno data
Physical and electrical
Density, cured polymer (MISSE 2 study table)1.317 g/cm³11190 kg/m3
Specific gravity, CR-39 comparative example1.32 specific gravity (unitless)21190 kg/m3
Density, liquid monomer ADC1.143 g/cm³31190 kg/m3
Temperature behavior
Heat resistance, equal to the glass transition per the source91 °C8144 °C
Other measurements
Refractive index, cured CR-391.498 unitless41.59 dimensionless
Refractive index, monomer ADC1.45 unitless51.59 dimensionless
Light transmittance, CR-39 comparative example91 %689 %
Light transmittance, commercial ADC plates92 %789 %
Continuous use temperature100 °C9no data
Linear expansion coefficient, CR-39 comparative example117 µm/m/°C10no data
Water absorption, CR-39 comparative example0.2 %11no data
Atomic oxygen erosion yield, MISSE 2 (lower bound)> 6.8×10^-24 cm³/atom124.29×10^-24 cm³/atom
Atomic oxygen erosion yield, predicted6.3×10^-24 cm³/atom134.29×10^-24 cm³/atom
Molar mass, repeat unit C12H18O7Printed in the NASA erosion study Table IV274.3 g/molno data
Optical absorption coefficient, UV-C band (215-242 nm)54 cm-114no data
Optical absorption coefficient, UV-A band (315-400 nm)1 cm-115no data
Polymerization time, CR-39 comparative examplePrinted in a patent comparative example table18 hoursno data

Why choose it, and why not

Good for

  • Light optical parts: 1.498 refractive index and 91 % light transmittance in the patent comparison.
  • Track detection: 3 % energy resolution for 2.9 MeV protons in the track-detector study.
  • Weight: about half the weight of glass for eyeglass lenses (Wikipedia).

Watch out for

  • Atomic oxygen: the MISSE 2 sample eroded through, with an erosion yield greater than 6.80e-24 cm3/atom.
  • UV at 254 nm: optical absorption reaches 54 cm-1 in the 215-242 nm band, and etch behaviour changes.
  • Monomer hazards: H302, H315 and H410 apply to the liquid monomer, and the cured polymer was not classified.

CR-39 is a clear, light thermoset with 1.498 refractive index, 91 % light transmittance and 100 °C continuous use, which suits eyeglass lenses and track detection. It is weak in low Earth orbit, where the MISSE 2 sample eroded through, and under short-wavelength UV.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Density, cured polymer (MISSE 2 study table)Value printed in the NASA erosion study, Table II, column g/cm3state cured polymertemperature not printed—
2Specific gravity, CR-39 comparative examplePrinted in a patent comparative example table (specific gravity, no unit printed)state cured polymertemperature not printed—
3Density, liquid monomer ADCValue printed in the Wikipedia infobox for diallyl diglycol carbonatestate liquid monomer, allyl diglycol carbonatetemperature not printed—
4Refractive index, cured CR-39Printed as n_D in a patent comparative example and in Wikipediawavelength not printedstate cured polymer—
5Refractive index, monomer ADCPrinted as nD in the Wikipedia infobox for the monomerstate liquid monomertemperature not printed—
6Light transmittance, CR-39 comparative examplePrinted as "Transparence" in a patent comparative example tablethickness not printedstate cured polymer—
7Light transmittance, commercial ADC platesPrinted in a patent table for commercial ADC platesthickness 2 mm platesstate commercial cured ADC—
8Heat resistance, equal to the glass transition per the sourcePrinted as heat resistance in a patent table; the text defines it as the temperature of maximum tan delta, which the patent calls Tgbasis temperature of maximum tan delta, which the source calls the glass transitionsample commercial ADC 2 mm plate—
9Continuous use temperaturePrinted in the Wikipedia article for CR-39 (citation needed on the short-term figure)duration continuousbasis optical use in eyeglasses—
10Linear expansion coefficient, CR-39 comparative examplePrinted in a patent comparative example table as linear expansion coefficienttemperature range not printedstate cured polymer—
11Water absorption, CR-39 comparative examplePrinted as water absorption rate in a patent comparative example tableduration not printedstate cured polymer—
12Atomic oxygen erosion yield, MISSE 2 (lower bound)Flight measurement reported in the NASA predictive-tool reportbound lower bound; the printed value is greater than 6.80e-24 because the sample eroded throughexposure MISSE 2 PEACE tray on the ISS—
13Atomic oxygen erosion yield, predictedPredicted value from the NASA predictive tool, compared with MISSE 2 in Table VIIexposure low Earth orbit atomic oxygen (predictive tool)—
14Optical absorption coefficient, UV-C band (215-242 nm)Maximum value computed from UV-Vis spectra in the cited studywavelength 215-242 nmexposure UV-exposed CR-39—
15Optical absorption coefficient, UV-A band (315-400 nm)Value computed from UV-Vis spectra in the cited studywavelength 315-400 nmexposure UV-exposed CR-39—
16Energy resolution, 2.9 MeV protonsPrinted in the track-detector study, energy resolution sectionparticle protons, 2.9 MeVdetector 1 mm slotted CR-39 plate—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
UV light (wavelength 254 nm and 365 nm, laboratory lamp) moderate UV at 254 nm changes CR-39 optical absorption and its etch rate; UV at 365 nm did not change them in the cited study.1
Atomic oxygen in low Earth orbit (MISSE 2, ISS, 3.95 years) severe The erosion yield is above 6.80e-24 cm3/atom, so the sample eroded through before the end of the exposure.2
Corrosion details
#EnvironmentDetailsTest conditions
1 UV light (wavelength 254 nm and 365 nm, laboratory lamp) At 254 nm the UV-Vis spectrum shows blue and red shifts and the band gap decreases with exposure time. At 365 nm there was no significant change in bulk etch rate or UV-Vis spectrum, even after 80 hours. The study also found that the bulk etch rate is modified by a factor that depends on the UV dose. exposure UV lamp 254 nm and 365 nm, 4 watt, samples 4 cm2etchant 6.25N NaOH at 70 °C
2 Atomic oxygen in low Earth orbit (MISSE 2, ISS, 3.95 years) The lower-bound erosion yield exceeds the predicted value of 6.30e-24 cm3/atom, so the true yield is at least as high as the measured lower bound. exposure MISSE 2 PEACE tray, ISS, outside the Quest airlock, 2001 to 2005

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

The monomer carries H302, H315 and H410 hazard statements. The cured polymer was not classified in the pages read.

Liquid monomer
Diallyl diglycol carbonate has GHS statements H302, H315 and H410 with signal word Warning (Wikipedia).

If it fails

UV and atomic oxygen both change the material, and the MISSE 2 sample eroded through.

UV at 254 nm
UV at 254 nm raises optical absorption to 54 cm-1 in the 215-242 nm band, while UV-A at 315-400 nm gives only 1 cm-1 (Section 2).
Atomic oxygen in orbit
The MISSE 2 erosion yield is greater than 6.80e-24 cm3/atom after 3.95 years on the ISS, so the true yield is at least that.

Handling and storage

Keep under the heat limit
Continuous use is up to 100 °C for optics (Wikipedia).

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
UV-induced change in optical absorption and etch behaviourmoderate severityExposure to short-wavelength UV (254 nm in the cited study)Optical absorption rises and etch behaviour changes, so calibration of the track detector can drift. Changes at 365 nm were not measurable in the study.
Atomic oxygen erosion in low Earth orbitcritical severityLong exposure to atomic oxygen on the ISS, MISSE 2 PEACE trayThe sample eroded through in the MISSE 2 flight, so its erosion yield is only a lower bound.

Handling and storage

  • Keep continuous use at or below 100 °C, since the Wikipedia article gives 130 °C only for up to one hour and marks it as citation needed.
  • Handle the liquid monomer with the GHS precautions printed for it (H302, H315, H410); the cured polymer was not classified in the pages read.

Supply and geography

How common the raw materials are and where they come from.

Diethylene glycol bis(allyl carbonate) monomer (ADC)

Top producers
United States

CR-39 track detectors (sold to researchers)

Top producers
United Kingdom, United States, Japan