Polytetrafluoroethylene PTFE
(-CF2-CF2-)n · CAS 9002-84-0
PTFE (Teflon) is a soft, slippery fluoropolymer that is an excellent electrical insulator and works from -200 degC to +260 degC according to a vendor sheet.
Evidence level
5 of 5
Flown or field-proven
- 0Predicted only. No one has made it, or no measurement exists.
- 1Calculated. Only calculated or predicted values from sources.
- 2Lab-measured. Measured properties with their conditions stated.
- 3Space-relevant tests. Measured in conditions relevant to space, such as vacuum or atomic oxygen.
- 4Ground-qualified. Qualified for an application on the ground.
- 5Flown or field-proven. Flight or field results exist.
Atomic oxygen
1.42e-25 cm3/atom
Outgassing
0.00% in the NASA listing
Heat
Melts at 327 °C
Electrical insulation
10^17 to 10^18 ohm cm
Low temperature
86.22 MPa at 77 K
Recipe, share of the weight
- C 24.0%Carbon
- F 76.0%Fluorine
Best for
A low-friction, electrically insulating, low-outgassing plastic that resists atomic oxygen far better than Kapton, PEEK or most hydrocarbon polymers
Weakest at
Ionizing radiation (it loses strength and stretch at megarad doses), low strength (23 to 27 MPa at room temperature) and heating above 300 degC, where it gives off toxic fumes
Risk at a glance
- People Moderate. Safe as a solid; toxic fumes if overheated
- If it fails High. Loss of strength and ductility under ionizing radiation
- Corrosion Severe. Overheated PTFE gives off toxic fumes.
Quick facts: PTFE
| Property | Value | Basis |
|---|---|---|
| Density | 2.14 to 2.18 g/cm³ | 3 sourced values across conditions |
| Tensile strength | 23 to 27 MPa | 1 sourced value |
| Thermal expansion (CTE) | 120 to 130 ppm/K | 1 sourced value |
| Melting point | 327 to 335 °C | 1 sourced value |
| Maximum service temperature | 260 °C | 1 sourced value |
What is the density of Polytetrafluoroethylene (PTFE)?
Polytetrafluoroethylene (PTFE) has a density of 2.14 to 2.18 g/cm³. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.
What is the coefficient of thermal expansion of Polytetrafluoroethylene (PTFE)?
Polytetrafluoroethylene (PTFE) has a coefficient of thermal expansion of 120 to 130 ppm/K. The source and test conditions are listed in the properties table on this page.
What is the melting point of Polytetrafluoroethylene (PTFE)?
Polytetrafluoroethylene (PTFE) has a melting point of 327 to 335 °C. The source and test conditions are listed in the properties table on this page.
What is the tensile strength of Polytetrafluoroethylene (PTFE)?
Polytetrafluoroethylene (PTFE) has a tensile strength of 23 to 27 MPa. The source and test conditions are listed in the properties table on this page.
What is the maximum service temperature of Polytetrafluoroethylene (PTFE)?
Polytetrafluoroethylene (PTFE) has a maximum service temperature of 260 °C. The source and test conditions are listed in the properties table on this page.
What is Polytetrafluoroethylene (PTFE) used for?
Uses recorded in the sources include Trailing umbilical cable insulation of the ISS Mobile Transporter (railcar), made of expanded PTFE; Spacecraft hook-up wire insulation (Teflon TFE and FEP); Candidate seal or liner material for liquid-hydrogen systems (ground tensile tests only).
Why it exists
Polytetrafluoroethylene (PTFE) is a polymer, a material made of very long chains of repeating units. Each unit is two carbon atoms each holding two fluorine atoms, written (-CF2-CF2-). Fluorine bonds very tightly to carbon and the fluorine coats the chain like a smooth sheath, which is why PTFE is famously slippery, chemically inert and a very good electrical insulator. A supplier sheet gives a density of about 2.17 g/cm3 (dense for a plastic), a dielectric constant of 2.1 and a volume resistivity of 10^17 to 10^18 ohm cm. PTFE melts at about 327 °C and a supplier lists a working range from -200 °C to +260 °C. The price of that tight bonding is that the chain is held together only weakly from one chain to the next, so PTFE is soft (23 to 27 MPa tensile strength) and, unlike most polymers, it is sensitive to ionizing radiation. In low Earth orbit it survives atomic oxygen well, but radiation snips the chains and leaves it brittle.
Where it's used
ISS railcar cable
The trailing umbilical cables of the ISS Mobile Transporter use an outer jacket of six layers of expanded PTFE, about 43 mils thick, with an inner core of 7 to 10 mils. The cable has a 10-year mission life and was installed in April 2002.
Spacecraft wire insulation
NASA's 1968 selection guide compared Teflon TFE and FEP with polyolefin insulations for spacecraft wire, ranking outgassing, radiation resistance and weight as the most important criteria.
Tested on the ground for hydrogen systems
Researchers at Southampton tested PTFE in tension at room temperature, 77 K and 20 K to judge it as an alternative to metal seals in cryogenic fuel systems. These were laboratory tests, not a seal in service.
Flown on the ISS as film
PTFE film was one of 40 polymers flown on the exterior of the ISS in the MISSE 2 experiment to measure atomic oxygen erosion over 3.95 years.
Recipe
(-CF2-CF2-)n
PTFE is made by free-radical polymerization of one monomer, tetrafluoroethylene (TFE, C2F4), initiated with persulfate such as potassium or ammonium persulfate (Wikipedia). Granular PTFE is made by suspension polymerization in water with agitation and often a surfactant; PTFE is also made by emulsion polymerization, where a surfactant keeps the polymer dispersed in water. TFE can explosively decompose to tetrafluoromethane and carbon, so the reaction needs special apparatus to prevent hot spots.
| Ingredient | Atoms per unit | Share of the weight | What it does |
|---|---|---|---|
| Carbon C | 2 | 24.0% | The two backbone carbons of each repeat unit, bonded to each other. |
| Fluorine F | 4 | 76.0% | Two fluorines on each backbone carbon. |
Weight shares are calculated from standard atomic weights.
What it can do
Atomic oxygen
1.42e-25 cm3/atom
On the MISSE 2 flight PTFE eroded at 1.42 × 10⁻²⁵ cm³/atom, at a fluence of 8.43e21 atoms/cm², against 3.00 × 10⁻²⁴ for Kapton H in the same table.
Outgassing
0.00% in the NASA listing
Outgassing is the release of trapped gases and volatile compounds in vacuum, which can then condense on optics and sensors. NASA's outgassing compilation lists a PTFE tubing product at 0.00% total mass loss (TML) and 0.00% condensable material (CVCM) after 24 hours at 125 °C in vacuum, and a PTFE wire insulation at 0.01% and 0.00%. These are finished products, not bulk resin.
Heat
Melts at 327 °C
A safety data sheet gives a melting point of 327 to 335 °C, and a supplier lists a service range of -200 °C to +260 °C. NASA's 1968 guide lists 260 °C as the maximum continuous service temperature of Teflon TFE wire insulation.
Electrical insulation
10^17 to 10^18 ohm cm
A supplier sheet gives a volume resistivity of 10^17 to 10^18 ohm cm, a dielectric strength of 30 to 45 kV/mm (0.5 mm specimen, ASTM D149) and a dielectric constant of 2.1.
Low temperature
86.22 MPa at 77 K
In tensile tests at 2 mm/min PTFE reached 18.15 MPa at room temperature, 86.22 MPa at 77 K and 82.32 MPa at 20 K. Strain at break fell to 4.44 percent at 77 K and 2.51 percent at 20 K, so it is much stronger but brittle when cold.
How it compares
In low Earth orbit PTFE eroded at 1.42 × 10⁻²⁵ cm³/atom, against 2.99 × 10⁻²⁴ for PEEK and 3.00 × 10⁻²⁴ for Kapton H in the same flight table; FEP measured 2.00 × 10⁻²⁵. In a room-temperature tension test at 2 mm/min PTFE reached 18.15 MPa, against 99.55 MPa for PEEK and 31.99 MPa for UHMWPE in the same study, and at 77 K it reached 86.22 MPa against 198.14 MPa for PEEK. For radiation, NASA Glenn describes PTFE as significantly more susceptible to radiation degradation than FEP.
The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.
| Measurement | PTFE | AF | PCTFE (CTFE, Kel-F) | ECTFE (Halar) | ETFE | FEP | PFA | PVDF (Kynar) | PVF | PVF (white Tedlar) |
|---|---|---|---|---|---|---|---|---|---|---|
| Thermal behavior and safety | ||||||||||
| Melting point (semi-finished PTFE) | 327 °C10 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Lifetime and stability | ||||||||||
| Total mass loss, PTFE tubing (GSFC data reference GSC17398) | 0 % mass17 | no data | no data | no data | no data | no data | 0.01 % mass | no data | no data | no data |
| Collected volatile condensable material, PTFE tubing (GSFC data reference GSC17398)Value printed in the NASA outgassing compilation | 0 % mass18 | no data | no data | no data | no data | no data | 0 % mass | no data | no data | no data |
| Volume resistivity | 1×10^17 ohm cm24 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Physical and electrical | ||||||||||
| Density (semi-finished PTFE) | 2.17 g/cm³1 | 2.146 g/cm³ | 2.133 g/cm³ | 1.68 g/cm³ | 1.74 g/cm³ | 2.144 g/cm³ | 2.138 g/cm³ | no data | 1.379 g/cm³ | 1.624 g/cm³ |
| Density range (machined PTFE stock) | 2.14 g/cm³2 | 2.146 g/cm³ | 2.133 g/cm³ | 1.68 g/cm³ | 1.74 g/cm³ | 2.144 g/cm³ | 2.138 g/cm³ | no data | 1.379 g/cm³ | 1.624 g/cm³ |
| Density used by NASA for the flown PTFE film | 2.15 g/cm³3 | 2.146 g/cm³ | 2.133 g/cm³ | 1.68 g/cm³ | 1.74 g/cm³ | 2.144 g/cm³ | 2.138 g/cm³ | no data | 1.379 g/cm³ | 1.624 g/cm³ |
| Temperature behavior | ||||||||||
| Tensile strength (room temperature, supplier typical) | 23 MPa4 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Tensile strength at room temperature (Southampton test) | 18.15 MPa6 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Glass transition temperatureQuoted literature value in a discussion section | 170 K11 | 160 °C | 45 °C | no data | no data | no data | no data | -40 °C | no data | -20 °C |
| Other measurements | ||||||||||
| Elongation at break (supplier typical) | > 230 %5 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Lowest service temperature (supplier) | -200 °C7 | no data | no data | -76 °C | no data | no data | no data | no data | -72 °C | -72 °C |
| Highest service temperature (supplier) | 260 °C8 | no data | 175 °C | 149 °C | 150 °C | 204 °C | 260 °C | no data | 107 °C | 107 °C |
| Highest continuous service temperature of Teflon TFE wire insulation (NASA, 1968) | 260 °C9 | no data | 175 °C | 149 °C | 150 °C | 204 °C | 260 °C | no data | 107 °C | 107 °C |
| Coefficient of linear thermal expansion (supplier typical, near room temperature) | 12 x 10^-5 per °C12 | no data | no data | 5.6×10^-5 in/in/°F | no data | no data | no data | no data | 2.8×10^-5 in/in/degF | 9.7×10^-5 m/mK |
| Mean coefficient of linear thermal expansion, 200 to 295 K | 103.1 x 10^-6 per K13 | no data | no data | 5.6×10^-5 in/in/°F | no data | no data | no data | no data | 2.8×10^-5 in/in/degF | 9.7×10^-5 m/mK |
| Ultimate tensile strength at 77 K | 86.22 MPa14 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Ultimate tensile strength at 20 K | 82.32 MPa15 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Atomic oxygen erosion | 1.42×10^-25 cm³/atom16 | 1.98×10^-25 cm³/atom | 8.31×10^-25 cm³/atom | 1.79×10^-24 cm³/atom | 9.61×10^-25 cm³/atom | 2×10^-25 cm³/atom | 1.73×10^-25 cm³/atom | 1.29×10^-24 cm³/atom | 3.19×10^-24 cm³/atom | 1.01×10^-25 cm³/atom |
| Weight loss of Teflon TFE insulated wire in high vacuum, 100 h | 0.04 % mass19 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Elongation lost after irradiation in high vacuum | 88 % of original elongation20 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Dose at which radiation damage becomes detectable (vendor summary) | 20000 rad21 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Dielectric constant | 2.1 dimensionless22 | 1.93 unitless | no data | 2.5 none | 2.6 dimensionless | 2.03 - | 2 - | no data | no data | 11 - |
| Dielectric strength | 30 kV/mm23 | 2.1 kV/0.1 mm | no data | 500 V/mil | no data | 80 kV/mm | 260 kV/mm | no data | no data | 3.5 kV/mil |
| Dynamic coefficient of friction (supplier typical, in air) | 0.05 dimensionless25 | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Limiting oxygen index | > 95 % oxygen26 | no data | no data | no data | no data | 95 % | no data | no data | no data | no data |
Why choose it, and why not
Good for
- Atomic oxygen resistance. The MISSE 2 erosion yield was 1.42 × 10⁻²⁵ cm³/atom, far below Kapton H at 3.00 × 10⁻²⁴.
- Electrical insulation. A supplier sheet gives a dielectric constant of 2.1 and a volume resistivity of 10^17 to 10^18 ohm cm.
- Low outgassing. NASA's listing shows PTFE tubing at 0.00% total mass loss and 0.00% condensable material after 24 hours at 125 °C.
- A very wide temperature range. A supplier lists -200 °C to +260 °C.
Watch out for
- Radiation. NASA TN D-4553 says Teflon TFE becomes useless after one or two megarads in air, and loses 88 percent of its elongation at 8 megarads in vacuum.
- Softness. Tensile strength is only 23 to 27 MPa at room temperature.
- Brittle when cold. Strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K.
- Overheating. Heating above 300 °C releases fumes, and above 400 °C toxic gases including hydrogen fluoride.
PTFE is a slippery, low-outgassing, electrically excellent plastic that resists atomic oxygen far better than most polymers, but it is soft and ionizing radiation breaks it down at doses of a few megarads. It suits shielded or short-exposure uses such as cable insulation, not a long-lived exposed surface. Only the MISSE 2 erosion yield here is a flight result; the radiation and cold figures are ground tests or literature summaries.
Technical details
For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.
Notes
The method, full conditions and any caveat for the numbered rows above.
| # | Measurement | Method | Conditions | Caveat |
|---|---|---|---|---|
| 1 | Density (semi-finished PTFE) | Value printed in a manufacturer safety data sheet (the sheet shows 2,17 gr/cm3 with a decimal comma) | form solid tubing, semi-finished PTFE productmanufacturer GAPI s.r.l., Italysheet date emission date 12/02/2007 | A Proto Labs sheet gives 2.14-2.18 g/cm3 (ASTM D792) and a Plastics International sheet gives a specific gravity of 2.13-2.22 (ASTM D792). The NASA MISSE 2 report uses 2.1503 g/cm3 for the flown PTFE film. |
| 2 | Density range (machined PTFE stock) | Typical-value range from a supplier material data sheet | test standard ASTM D792form CNC machining stock, supplier typical values | The sheet shows 2.14-2.18 g/cm3 in both its imperial and metric columns. |
| 3 | Density used by NASA for the flown PTFE film | Density value listed in the NASA report for the erosion-yield calculation | sample PTFE film flown on MISSE 2 PEACE Polymersash fraction 2.98e-4 | — |
| 4 | Tensile strength (room temperature, supplier typical) | Typical-value range from a supplier material data sheet (also printed as 3,335-3,917 psi) | test standard ISO 12086 / ISO 527 / ASTM D4894temperature room temperature, not stated on the sheetform CNC machining stock | A Plastics International sheet gives 3,000-5,000 psi (ASTM D1457, D1708, D638) at 73 degF (23 degC). In the Southampton cryogenic tests the PTFE sheet gave a lower figure, 18.15 MPa at 2 mm/min. |
| 5 | Elongation at break (supplier typical) | Minimum value printed in a supplier material data sheet (listed as 230% or more) | test standard ISO 12086 / ISO 527 / ASTM D4894form CNC machining stock | A Plastics International sheet gives 300-500 percent (ASTM D1457, D1708, D638) at 73 degF (23 degC). The Southampton sheet specimen stretched about 303 percent at 2 mm/min. |
| 6 | Tensile strength at room temperature (Southampton test) | Tensile test in a cryogenic test rig (mean of repeats) | temperature room temperature (295 K)crosshead speed 2 mm/min (0.00159 /s)specimen dumbbell cut by waterjet from flat sheet, ISO 37 Type I profile, PTFE grade not stated | Uncertainty: standard deviation 0.49 MPaYoung's modulus 0.82 GPa and strain at break 302.96 percent in the same row. At 250 mm/min the strength was 19.23 MPa. In the same table at 2 mm/min PEEK gave 99.55 MPa and UHMWPE 31.99 MPa; in Table 2 at 77 K PEEK gave 198.14 MPa. This is a prefinal preprint. |
| 7 | Lowest service temperature (supplier) | Value printed in a supplier material data sheet; no test method is listed for it | basis supplier-stated service range (printed as -328 degF)form CNC machining stock | This is a stated limit, not a measured one. The Southampton tests found PTFE much stronger but far less stretchy at 77 K and 20 K (see the cryogenic strength entries). |
| 8 | Highest service temperature (supplier) | Value printed in a supplier material data sheet; no test method is listed for it | basis supplier-stated service range (printed as +500 degF)form CNC machining stock | A Plastics International sheet gives an upper service temperature of 500 degF for 20,000 h (UL746B). NASA TN D-4553 (1968) lists 260 degC as the maximum recommended continuous service temperature for Teflon TFE wire insulation. |
| 9 | Highest continuous service temperature of Teflon TFE wire insulation (NASA, 1968) | Value stated in a NASA guide for selecting wire insulation (the same list gives 205 degC for Teflon FEP) | use hook-up wire insulation for spacecraftbasis maximum recommended continuous duty service temperature | — |
| 10 | Melting point (semi-finished PTFE) | Value printed in a manufacturer safety data sheet | form semi-finished PTFE productnote the sheet prints 327/335 °C | The Plastics International sheet gives 621 degF (ASTM D3418), which converts to 327 degC (Space Mushroom conversion). |
| 11 | Glass transition temperature | — | basis value quoted by the authors from other papers, not measured in the studycomparison PEEK 416 K, UHMWPE 123 K | The authors use it to explain why PTFE is ductile at room temperature but brittle at 77 K and 20 K, both below this temperature. |
| 12 | Coefficient of linear thermal expansion (supplier typical, near room temperature) | Typical-value range from a supplier material data sheet (equal to 120-130 ppm/K) | test standard ASTM D696temperature range not stated on the sheetform CNC machining stock | Measured on a sheet in the Southampton study, expansion is strongly temperature dependent, from 8.28e-6 per K (20-50 K) to 103.06e-6 per K (200-295 K). |
| 13 | Mean coefficient of linear thermal expansion, 200 to 295 K | Linear CTE calculated from a measured contraction curve | temperature range 200 to 295 Kspecimen PTFE sheet, grade not statedmethod detail contraction measured between 20 K and 295 K | Uncertainty: standard deviation 0.04Other ranges in the same table: 8.28 (20-50 K), 25.28 (50-123 K) and 62.31 (123-200 K) x 10^-6 per K. Between 295 K and 20 K the PTFE contracted by about 1.7 percent, against 0.9 percent for PEEK (Section 3.2). |
| 14 | Ultimate tensile strength at 77 K | Tensile test in a cryogenic test rig (mean of repeats) | temperature 77 Kcrosshead speed 2 mm/minspecimen dumbbell cut from flat sheet by waterjet (ISO 37 Type I profile), PTFE grade not stated | Uncertainty: standard deviation 0.23 MPaYoung's modulus 5.71 GPa and strain at break 4.44 percent in the same row. This is a prefinal preprint. |
| 15 | Ultimate tensile strength at 20 K | Tensile test in a cryogenic test rig (mean of repeats) | temperature 20 Kcrosshead speed 2 mm/minspecimen dumbbell cut from flat sheet by waterjet (ISO 37 Type I profile), PTFE grade not stated | Uncertainty: standard deviation 0.59 MPaStrain at break was 2.51 percent, against 302.96 percent at room temperature. At 250 mm/min the 20 K strength was 92.78 MPa. |
| 16 | Atomic oxygen erosion | Mass-loss erosion yield from the MISSE 2 flight samples, as compiled in the NASA report | experiment MISSE 2 PEACE polymers, exterior of the International Space Stationexposure 3.95 yr in low Earth orbit, 16 August 2001 to 30 July 2005fluence 8.43e21 atoms/cm2comparison Kapton H polyimide measured 3.00e-24 cm3/atom in the same table | The report's predictive tool gave 1.58e-25 cm3/atom for PTFE (Table VII). Density used was 2.1503 g/cm3 and ash fraction 2.98e-4 (Table II). The report says some stacked thin-film samples eroded through, so some listed yields are lower bounds; PTFE is listed without a greater-than sign. |
| 17 | Total mass loss, PTFE tubing (GSFC data reference GSC17398) | Value printed in the NASA outgassing compilation; a finished commercial product, not a bulk resin | specimen PTFE TUBING AS 20-065-1, manufacturer code ZEUtest standard NASA GSFC screening test, ASTM E595 typetemperature 398 K (125 °C), 24 h in vacuumacceptance TML at most 1.0 percent and CVCM at most 0.10 percent | Water vapour regained (WVR) was 0.00 percent in the same row. A second PTFE entry, TFE wire insulation (GSFC6086, manufacturer MSY), has TML 0.01, CVCM 0.00 and WVR 0.00 percent. Note that GSFC10661, which a Gund Company bulletin labels PTFE/FEP at 0.01/0.00/0.02, is listed in RP-1124 as TEFLON FEP TYPE A 5 MIL FILM, so it is not used here as PTFE. |
| 18 | Collected volatile condensable material, PTFE tubing (GSFC data reference GSC17398) | — | specimen PTFE TUBING AS 20-065-1, manufacturer code ZEUtest standard NASA GSFC screening test, ASTM E595 typetemperature 398 K (125 °C), 24 h in vacuum | The TFE wire insulation entry (GSFC6086) also shows CVCM 0.00 percent. |
| 19 | Weight loss of Teflon TFE insulated wire in high vacuum, 100 h | Weight loss in high vacuum, reported in NASA TN D-4553 from earlier work (its references 3 and 4) | specimen Teflon TFE insulated wire, sample weight 2.0 gtemperature 212 degF (100 °C)time in vacuum 100 hours | A second row gives 0.29 percent after 168 hours at 300 degF (149 degC). The report says gross weight losses of the insulations are small and acceptable, and mainly due to entrapped gases such as carbon dioxide and water. |
| 20 | Elongation lost after irradiation in high vacuum | Statement in a NASA guide for selecting wire insulation (a literature summary) | dose 8 megarads (Mrad)atmosphere high vacuummaterial Teflon TFEradiation ionizing radiation, type not stated in this passage | The same passage says that irradiated in air, Teflon TFE is quickly degraded and becomes useless after absorbing one or two megarads. 8 megarads equals 80 kGy. A dose tested, not a limit. |
| 21 | Dose at which radiation damage becomes detectable (vendor summary) | Summary table in a Rogers Corporation technical article, compiled from literature references dated 1951 to 1969 | atmosphere in airthreshold first detectable mechanical damagevacuum equivalent 2-7 x 10^5 rad or more in vacuum | 2 to 7 x 10^4 rad is 200 to 700 Gy. In the same table 50 percent of tensile strength is retained at 10^6 rad in air and 10^7 rad or more in vacuum, and 100 percent elongation is retained to 2-5 x 10^5 rad in air and 2-5 x 10^6 rad in vacuum. The article says damage is smaller in vacuum because oxygen takes part in the damaging reactions. The source is a vendor article about PTFE-filled laminates; the table layout in the PDF is partly ambiguous, so only the clear rows are quoted. |
| 22 | Dielectric constant | Typical value printed in a supplier material data sheet | basis typical value in a supplier sheettemperature 73 degF (23 °C)test method not listed for this row | The sheet says the dielectric constant and loss factor are low and stable across a wide temperature and frequency range. |
| 23 | Dielectric strength | Typical-value range from a supplier material data sheet (printed as 762-1,143 V/mil) | test standard ASTM D149specimen thickness 0.5 mm | Dielectric strength depends strongly on specimen thickness. |
| 24 | Volume resistivity | Typical-value range from a supplier material data sheet (printed as 10^17-10^18 ohm-cm) | test standard ASTM D257form CNC machining stock | Surface resistivity is listed as 10^16-10^17 ohm. |
| 25 | Dynamic coefficient of friction (supplier typical, in air) | Typical-value range from a supplier material data sheet | test standard ASTM D1894 / ASTM D3702atmosphere air, not vacuum | A Plastics International sheet gives 0.1 (ASTM D1894, below 10 ft/min). No vacuum friction value was found. |
| 26 | Limiting oxygen index | Typical value printed in a supplier material data sheet | test standard ASTM D2863sheet note printed as greater than 95 percent | The same sheet lists a UL94 flame rating of V-0 and a heat of combustion of 2,200 Btu/lb. This is a ground flammability screen in air, not the NASA-STD-6001 crew-safety test. |
Corrosion and compatibility
What happens when it meets other materials and environments.
| Environment | Concern | What happens |
|---|---|---|
| Atomic oxygen in low Earth orbit | low | Atomic oxygen eroded PTFE about twenty times more slowly than Kapton H on the ISS.1 |
| Heat above 300 degC (decomposition) | severe | Overheated PTFE gives off toxic fumes.2 |
| Chemicals and water | not rated | The sheet says PTFE does not dissolve in water or organic solvents, but no corrosion test was opened.3 |
| # | Environment | Details | Test conditions |
|---|---|---|---|
| 1 | Atomic oxygen in low Earth orbit | On the MISSE 2 flight PTFE had an erosion yield of 1.42e-25 cm3/atom, against 3.00e-24 for Kapton H and 2.99e-24 for PEEK in the same table. Other fluoropolymers were similar: FEP 2.00e-25 and PFA 1.73e-25. | flight MISSE 2, 3.95 yr, fluence 8.43e21 atoms/cm2 |
| 2 | Heat above 300 degC (decomposition) | A PTFE safety data sheet says heating above 300 degC may release a fine particulate fume and, above 400 degC, decomposition products that can cause pulmonary inflammation, haemorrhage or oedema. Combustion or thermal decomposition gives very toxic and corrosive vapours such as hydrogen fluoride (HF) and carbonyl fluoride (COF2). | trigger overheating or burningworst case poor ventilation or confined spaces |
| 3 | Chemicals and water | The semi-finished PTFE safety data sheet lists solubility as 'Not in water or in organic solvent' and the product as stable at normal temperatures and storage conditions. Suppliers describe PTFE as chemically resistant, but no quantitative chemical-resistance table was opened for this profile. | basis manufacturer safety data sheet, semi-finished PTFE products |
Risks and side effects
Hazards to people, what happens when a cell overheats, and how the material is handled and stored.
For people
The solid is described as not toxic, but heating PTFE above 300 °C can make you ill and above 400 °C can injure the lungs.
- The solid
- A manufacturer safety data sheet (emission date 12/02/2007) says the solid is not classified as hazardous for transport, is not carcinogenic and is not toxic if swallowed. It ignites if a flame is applied, but combustion stops when the flame is removed.
- Polymer fume fever
- Heating PTFE above 300 °C may release a fine fume that causes polymer fume fever, a flu-like illness with fever, chills, nausea and chest tightness. Symptoms are often delayed 4 to 24 hours and last 24 to 48 hours.
- Hotter than 400 °C
- Above 400 °C the decomposition products may cause pulmonary inflammation, haemorrhage or oedema, especially in poor ventilation or confined spaces. Combustion gives very toxic and corrosive vapours such as hydrogen fluoride and carbonyl fluoride.
If it fails
These results come from a 1968 NASA guide, a NASA Glenn prediction and laboratory tests, not from a reported failure of a flown PTFE part.
- Under radiation
- NASA TN D-4553 says Teflon TFE irradiated in air becomes useless after one or two megarads, and in high vacuum loses 88 percent of its elongation at 8 megarads. Radiation breaks the long molecular chains, so the plastic turns brittle.
- In orbit
- A NASA Glenn study of the expanded PTFE cable on the ISS predicts a badly embrittled front surface, with cracks starting early and reaching about 0.030 cm deep after a 10-year mission. This is a ground-based prediction.
- At hydrogen temperature
- In tensile tests at 2 mm/min, PTFE strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K, so the sheet went from stretchy to brittle.
Handling and storage
- Keep it cool
- The safety data sheet advises against using the material at high temperature (it says 280 °C), taking care to prevent inhaling fume, and not smoking while handling it.
- Ventilate
- Use local exhaust ventilation to remove fumes. In a fire wear self-contained breathing apparatus, because hydrogen fluoride fumes can react with water to form hydrofluoric acid.
- Waste
- The sheet says the solid is stable in normal storage and suggests recycling where possible, and disposal must follow local regulations.
Test details
The original wording and numbers from the sources, for readers who want them.
Failure risks
| Failure | Trigger and consequence |
|---|---|
| Loss of strength and ductility under ionizing radiationhigh severity | Absorbed doses of one to two megarads in air, or 8 megarads in high vacuumIn air Teflon TFE is quickly degraded and becomes useless after one or two megarads; in vacuum it loses 88 percent of its original elongation at 8 megarads. The primary effect is chain breaking, which lowers molecular weight and makes the plastic brittle. |
| Surface cracking of ePTFE cable insulation on the ISS (predicted)moderate severity | 10-year mission with thermal cycling from -100 to 130 degC and ionizing radiationA NASA Glenn analysis predicts an extremely embrittled front surface with cracks under any given strain, and microscopic cracks starting very early in the mission to a depth of about 0.030 cm after 10 years. This is a ground-based prediction, not a flight failure. |
| Brittleness at hydrogen temperaturemoderate severity | Cooling from room temperature to 20 KAt 2 mm/min strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K, and the sheet contracted by about 1.7 percent between 295 K and 20 K. |
Side effects on surrounding parts
| Affects | Effect |
|---|---|
| Nearby optics and metal surfaces | Irradiated polymers, almost without exception, release gaseous substances that may corrode spacecraft parts. In the report's mirror tests, vacuum-deposited copper and aluminium mirrors were sealed in ampoules with irradiated insulation, including Teflon TFE, and examined for corrosion. |
| Choice between PTFE and FEP for exposed insulation | NASA Glenn describes PTFE as known to be significantly more susceptible to radiation degradation than FEP. |
Handling and storage
- Use usual protective clothing; avoid using the material at high temperature (the sheet says 280 degC) and take care to prevent inhalation of fume. No smoking while handling. Prevent burns from contact with hot material, hot surfaces and flames.
- Store at normal temperatures; the product is stable under normal storage conditions. Treatment and disposal must follow local regulations, and recycling is suggested if possible.
Mitigations
- Use local exhaust ventilation to remove vapours and fumes. Wear safety glasses, heat-resistant clothing and footwear, and a face shield if molten polymer might splash. In a fire, use self-contained breathing apparatus and full protective equipment.
Supply and geography
How common the raw materials are and where they come from.
Fluorine feedstock (fluorspar, calcium fluoride)
- Top producers (2025)
- China 60%, Mexico 15%, Mongolia 15%, South Africa 4.1%
- Recycling
- USGS: synthetic fluorspar may be produced from neutralization of waste in uranium enrichment, petroleum alkylation and stainless-steel pickling, though impurities constrain its use. Primary aluminum producers recycle HF and fluorides from smelting.
- Substitutes
- USGS: fluosilicic acid from phosphate rock has been used as an alternative to fluorspar in making AlF3 and HF (about 73,000 tons of fluorspar equivalent was recovered in 2025).
PTFE resin producers
Documents
Datasheets, safety data sheets, papers and standards you can open.
Full record
The complete spore, as stored. Free to reuse under CC-BY-4.0. Images keep the licence shown with each one.
Show the full YAML
spore: profile
id: ptfe
spore_version: 0.2
family: fluoropolymers
name: Polytetrafluoroethylene
abbreviation: PTFE
role: low-friction insulating and chemically inert polymer
category: polymers
type: fluoropolymers
summary: |
PTFE (Teflon) is a soft, slippery fluoropolymer that is an excellent electrical insulator and works from -200 degC to +260 degC according to a vendor sheet. On the MISSE 2 flight it eroded under atomic oxygen at 1.42e-25 cm3/atom, about twenty times slower than Kapton H. Its weakness is radiation: NASA wire-insulation guidance from 1968 says PTFE irradiated in air becomes useless after one or two megarads, and a NASA Glenn study calls it much more radiation-sensitive than FEP.
best_for: A low-friction, electrically insulating, low-outgassing plastic that resists atomic oxygen far better than Kapton, PEEK or most hydrocarbon polymers
weakest_at: Ionizing radiation (it loses strength and stretch at megarad doses), low strength (23 to 27 MPa at room temperature) and heating above 300 degC, where it gives off toxic fumes
identity:
formula: (-CF2-CF2-)n
cas: 9002-84-0
source: utd-sds
where: Section 1.1 (polytetrafluoroethylene, CAS 9002-84-0); formula written out by Space Mushroom from the name and from the NASA tables, which list the repeat unit as C2F4
tags:
environments:
- low-earth-orbit
stresses:
- atomic-oxygen
- total-radiation-dose
- thermal-cycling
- extreme-cold
- vacuum-and-outgassing
applications:
- electronics-and-chips
- cryogenic-fuel
properties:
- benchmark: density
label: Density (semi-finished PTFE)
value: 2.17
unit: g/cm3
scope: material
conditions:
form: solid tubing, semi-finished PTFE product
manufacturer: GAPI s.r.l., Italy
sheet_date: emission date 12/02/2007
method: Value printed in a manufacturer safety data sheet (the sheet shows 2,17 gr/cm3 with a decimal comma)
status: ground
note: A Proto Labs sheet gives 2.14-2.18 g/cm3 (ASTM D792) and a Plastics International sheet gives a specific gravity of 2.13-2.22 (ASTM D792). The NASA MISSE 2 report uses 2.1503 g/cm3 for the flown PTFE film.
source: utd-sds
where: Section 9 (Physical and chemical properties)
- benchmark: density
label: Density range (machined PTFE stock)
value: 2.14
value_high: 2.18
unit: g/cm3
scope: material
conditions:
test_standard: ASTM D792
form: CNC machining stock, supplier typical values
method: Typical-value range from a supplier material data sheet
status: ground
note: The sheet shows 2.14-2.18 g/cm3 in both its imperial and metric columns.
source: protolabs
where: Properties table (Density)
- benchmark: density
label: Density used by NASA for the flown PTFE film
value: 2.1503
unit: g/cm3
scope: material
conditions:
sample: PTFE film flown on MISSE 2 PEACE Polymers
ash_fraction: '2.98e-4'
method: Density value listed in the NASA report for the erosion-yield calculation
status: ground
source: banks2008
where: Table II (polymer physical properties)
- benchmark: tensile_strength_room_temperature
label: Tensile strength (room temperature, supplier typical)
value: 23
value_high: 27
unit: MPa
scope: material
conditions:
test_standard: ISO 12086 / ISO 527 / ASTM D4894
temperature: room temperature, not stated on the sheet
form: CNC machining stock
method: Typical-value range from a supplier material data sheet (also printed as 3,335-3,917 psi)
status: ground
note: A Plastics International sheet gives 3,000-5,000 psi (ASTM D1457, D1708, D638) at 73 degF (23 degC). In the Southampton cryogenic tests the PTFE sheet gave a lower figure, 18.15 MPa at 2 mm/min.
source: protolabs
where: Properties table (Tensile Strength)
- benchmark: elongation_at_break_supplier_typical
label: Elongation at break (supplier typical)
value: 230
unit: '%'
bound: lower
scope: material
conditions:
test_standard: ISO 12086 / ISO 527 / ASTM D4894
form: CNC machining stock
method: Minimum value printed in a supplier material data sheet (listed as 230% or more)
status: ground
note: A Plastics International sheet gives 300-500 percent (ASTM D1457, D1708, D638) at 73 degF (23 degC). The Southampton sheet specimen stretched about 303 percent at 2 mm/min.
source: protolabs
where: Properties table (Elongation at Break)
- benchmark: tensile_strength_at_room_temperature
label: Tensile strength at room temperature (Southampton test)
value: 18.15
unit: MPa
scope: material
conditions:
temperature: room temperature (295 K)
crosshead_speed: 2 mm/min (0.00159 /s)
specimen: dumbbell cut by waterjet from flat sheet, ISO 37 Type I profile, PTFE grade not stated
method: Tensile test in a cryogenic test rig (mean of repeats)
status: ground
uncertainty: standard deviation 0.49 MPa
note: Young's modulus 0.82 GPa and strain at break 302.96 percent in the same row. At 250 mm/min the strength was 19.23 MPa. In the same table at 2 mm/min PEEK gave 99.55 MPa and UHMWPE 31.99 MPa; in Table 2 at 77 K PEEK gave 198.14 MPa. This is a prefinal preprint.
source: wang2024
where: Table 1 (strain rate effects at room temperature)
- benchmark: min_service_temp
label: Lowest service temperature (supplier)
value: -200
unit: degC
scope: material
conditions:
basis: supplier-stated service range (printed as -328 degF)
form: CNC machining stock
method: Value printed in a supplier material data sheet; no test method is listed for it
status: ground
note: This is a stated limit, not a measured one. The Southampton tests found PTFE much stronger but far less stretchy at 77 K and 20 K (see the cryogenic strength entries).
source: protolabs
where: Properties table (Service Temperature min-max)
- benchmark: max_service_temp
label: Highest service temperature (supplier)
value: 260
unit: degC
scope: material
conditions:
basis: supplier-stated service range (printed as +500 degF)
form: CNC machining stock
method: Value printed in a supplier material data sheet; no test method is listed for it
status: ground
note: A Plastics International sheet gives an upper service temperature of 500 degF for 20,000 h (UL746B). NASA TN D-4553 (1968) lists 260 degC as the maximum recommended continuous service temperature for Teflon TFE wire insulation.
source: protolabs
where: Properties table (Service Temperature min-max)
- benchmark: max_service_temp
label: Highest continuous service temperature of Teflon TFE wire insulation (NASA, 1968)
value: 260
unit: degC
scope: material
conditions:
use: hook-up wire insulation for spacecraft
basis: maximum recommended continuous duty service temperature
method: Value stated in a NASA guide for selecting wire insulation (the same list gives 205 degC for Teflon FEP)
status: ground
source: nasa-tnd4553
where: Section on temperature characteristics (page 12)
- benchmark: melting_point_semi_finished_ptfe
label: Melting point (semi-finished PTFE)
value: 327
value_high: 335
unit: degC
scope: material
conditions:
form: semi-finished PTFE product
note: the sheet prints 327/335 degC
method: Value printed in a manufacturer safety data sheet
status: ground
note: The Plastics International sheet gives 621 degF (ASTM D3418), which converts to 327 degC (Space Mushroom conversion).
source: utd-sds
where: Section 9 (Melting Point)
- benchmark: glass_transition_temperature
label: Glass transition temperature
value: 170
unit: K
scope: material
conditions:
basis: value quoted by the authors from other papers, not measured in the study
comparison: PEEK 416 K, UHMWPE 123 K
method: Quoted literature value in a discussion section
status: ground
note: The authors use it to explain why PTFE is ductile at room temperature but brittle at 77 K and 20 K, both below this temperature.
source: wang2024
where: Section 4 (Discussion)
- benchmark: cte
label: Coefficient of linear thermal expansion (supplier typical, near room temperature)
value: 12
value_high: 13
unit: x 10^-5 per degC
scope: material
conditions:
test_standard: ASTM D696
temperature_range: not stated on the sheet
form: CNC machining stock
method: Typical-value range from a supplier material data sheet (equal to 120-130 ppm/K)
status: ground
note: Measured on a sheet in the Southampton study, expansion is strongly temperature dependent, from 8.28e-6 per K (20-50 K) to 103.06e-6 per K (200-295 K).
source: protolabs
where: Properties table (Coefficient of Linear Thermal Expansion)
- benchmark: cte
label: Mean coefficient of linear thermal expansion, 200 to 295 K
value: 103.06
unit: x 10^-6 per K
scope: material
conditions:
temperature_range: 200 to 295 K
specimen: PTFE sheet, grade not stated
method_detail: contraction measured between 20 K and 295 K
method: Linear CTE calculated from a measured contraction curve
status: ground
uncertainty: standard deviation 0.04
note: 'Other ranges in the same table: 8.28 (20-50 K), 25.28 (50-123 K) and 62.31 (123-200 K) x 10^-6 per K. Between 295 K and 20 K the PTFE contracted by about 1.7 percent, against 0.9 percent for PEEK (Section 3.2).'
source: wang2024
where: Table 4; Section 3.2
- benchmark: ultimate_tensile_strength_at_77_k
label: Ultimate tensile strength at 77 K
value: 86.22
unit: MPa
scope: material
conditions:
temperature: 77 K
crosshead_speed: 2 mm/min
specimen: dumbbell cut from flat sheet by waterjet (ISO 37 Type I profile), PTFE grade not stated
method: Tensile test in a cryogenic test rig (mean of repeats)
status: ground
uncertainty: standard deviation 0.23 MPa
note: Young's modulus 5.71 GPa and strain at break 4.44 percent in the same row. This is a prefinal preprint.
source: wang2024
where: Table 2 (77 K)
- benchmark: ultimate_tensile_strength_at_20_k
label: Ultimate tensile strength at 20 K
value: 82.32
unit: MPa
scope: material
conditions:
temperature: 20 K
crosshead_speed: 2 mm/min
specimen: dumbbell cut from flat sheet by waterjet (ISO 37 Type I profile), PTFE grade not stated
method: Tensile test in a cryogenic test rig (mean of repeats)
status: ground
uncertainty: standard deviation 0.59 MPa
note: Strain at break was 2.51 percent, against 302.96 percent at room temperature. At 250 mm/min the 20 K strength was 92.78 MPa.
source: wang2024
where: Table 3 (20 K)
- benchmark: atomic_oxygen_erosion_yield
value: 1.42e-25
unit: cm3/atom
scope: material
conditions:
experiment: MISSE 2 PEACE polymers, exterior of the International Space Station
exposure: 3.95 yr in low Earth orbit, 16 August 2001 to 30 July 2005
fluence: 8.43e21 atoms/cm2
comparison: Kapton H polyimide measured 3.00e-24 cm3/atom in the same table
method: Mass-loss erosion yield from the MISSE 2 flight samples, as compiled in the NASA report
status: flight
note: The report's predictive tool gave 1.58e-25 cm3/atom for PTFE (Table VII). Density used was 2.1503 g/cm3 and ash fraction 2.98e-4 (Table II). The report says some stacked thin-film samples eroded through, so some listed yields are lower bounds; PTFE is listed without a greater-than sign.
source: banks2008
where: Table I (MISSE 2 PEACE polymers erosion yield data); Table VII; Section 2.1 for exposure
- benchmark: outgassing_tml
label: Total mass loss, PTFE tubing (GSFC data reference GSC17398)
value: 0
unit: '% mass'
scope: material
conditions:
specimen: PTFE TUBING AS 20-065-1, manufacturer code ZEU
test_standard: NASA GSFC screening test, ASTM E595 type
temperature: 398 K (125 degC), 24 h in vacuum
acceptance: TML at most 1.0 percent and CVCM at most 0.10 percent
method: Value printed in the NASA outgassing compilation; a finished commercial product, not a bulk resin
status: ground
note: Water vapour regained (WVR) was 0.00 percent in the same row. A second PTFE entry, TFE wire insulation (GSFC6086, manufacturer MSY), has TML 0.01, CVCM 0.00 and WVR 0.00 percent. Note that GSFC10661, which a Gund Company bulletin labels PTFE/FEP at 0.01/0.00/0.02, is listed in RP-1124 as TEFLON FEP TYPE A 5 MIL FILM, so it is not used here as PTFE.
source: rp1124
where: Section B alphabetical listing, entry PTFE TUBING AS 20-065-1; test method on page 2 of the introduction
- benchmark: outgassing_cvcm
label: Collected volatile condensable material, PTFE tubing (GSFC data reference GSC17398)
value: 0
unit: '% mass'
scope: material
conditions:
specimen: PTFE TUBING AS 20-065-1, manufacturer code ZEU
test_standard: NASA GSFC screening test, ASTM E595 type
temperature: 398 K (125 degC), 24 h in vacuum
method: Value printed in the NASA outgassing compilation
status: ground
note: The TFE wire insulation entry (GSFC6086) also shows CVCM 0.00 percent.
source: rp1124
where: Section B alphabetical listing, entry PTFE TUBING AS 20-065-1
- benchmark: weight_loss_of_teflon_tfe_insulated
label: Weight loss of Teflon TFE insulated wire in high vacuum, 100 h
value: 0.04
unit: '% mass'
scope: material
conditions:
specimen: Teflon TFE insulated wire, sample weight 2.0 g
temperature: 212 degF (100 degC)
time_in_vacuum: 100 hours
method: Weight loss in high vacuum, reported in NASA TN D-4553 from earlier work (its references 3 and 4)
status: ground
note: A second row gives 0.29 percent after 168 hours at 300 degF (149 degC). The report says gross weight losses of the insulations are small and acceptable, and mainly due to entrapped gases such as carbon dioxide and water.
source: nasa-tnd4553
where: Table 1
- benchmark: elongation_lost_after_irradiation_in
label: Elongation lost after irradiation in high vacuum
value: 88
unit: '% of original elongation'
scope: material
conditions:
dose: 8 megarads (Mrad)
atmosphere: high vacuum
material: Teflon TFE
radiation: ionizing radiation, type not stated in this passage
method: Statement in a NASA guide for selecting wire insulation (a literature summary)
status: ground
note: The same passage says that irradiated in air, Teflon TFE is quickly degraded and becomes useless after absorbing one or two megarads. 8 megarads equals 80 kGy. A dose tested, not a limit.
source: nasa-tnd4553
where: Section on radiation resistance
- benchmark: dose_at_which_radiation_damage
label: Dose at which radiation damage becomes detectable (vendor summary)
value: 20000
value_high: 70000
unit: rad
scope: material
conditions:
atmosphere: in air
threshold: first detectable mechanical damage
vacuum_equivalent: 2-7 x 10^5 rad or more in vacuum
method: Summary table in a Rogers Corporation technical article, compiled from literature references dated 1951 to 1969
status: ground
note: 2 to 7 x 10^4 rad is 200 to 700 Gy. In the same table 50 percent of tensile strength is retained at 10^6 rad in air and 10^7 rad or more in vacuum, and 100 percent elongation is retained to 2-5 x 10^5 rad in air and 2-5 x 10^6 rad in vacuum. The article says damage is smaller in vacuum because oxygen takes part in the damaging reactions. The source is a vendor article about PTFE-filled laminates; the table layout in the PDF is partly ambiguous, so only the clear rows are quoted.
source: rogers-radiation
where: Page 1, summary table of radiation doses related to damage levels
- benchmark: dielectric_constant
label: Dielectric constant
value: 2.1
unit: dimensionless
scope: material
conditions:
basis: typical value in a supplier sheet
temperature: 73 degF (23 degC)
test_method: not listed for this row
method: Typical value printed in a supplier material data sheet
status: ground
note: The sheet says the dielectric constant and loss factor are low and stable across a wide temperature and frequency range.
source: plasticsintl
where: Introductory text
- benchmark: dielectric_strength
label: Dielectric strength
value: 30
value_high: 45
unit: kV/mm
scope: material
conditions:
test_standard: ASTM D149
specimen_thickness: 0.5 mm
method: Typical-value range from a supplier material data sheet (printed as 762-1,143 V/mil)
status: ground
note: Dielectric strength depends strongly on specimen thickness.
source: protolabs
where: Properties table (Dielectric Strength)
- benchmark: volume_resistivity
label: Volume resistivity
value: 100000000000000000
value_high: 1000000000000000000
unit: ohm cm
scope: material
conditions:
test_standard: ASTM D257
form: CNC machining stock
method: Typical-value range from a supplier material data sheet (printed as 10^17-10^18 ohm-cm)
status: ground
note: Surface resistivity is listed as 10^16-10^17 ohm.
source: protolabs
where: Properties table (Volume Resistivity)
- benchmark: dynamic_coefficient_of_friction
label: Dynamic coefficient of friction (supplier typical, in air)
value: 0.05
value_high: 0.06
unit: dimensionless
scope: material
conditions:
test_standard: ASTM D1894 / ASTM D3702
atmosphere: air, not vacuum
method: Typical-value range from a supplier material data sheet
status: ground
note: A Plastics International sheet gives 0.1 (ASTM D1894, below 10 ft/min). No vacuum friction value was found.
source: protolabs
where: Properties table (Dynamic Coefficient of Friction)
- benchmark: limiting_oxygen_index
label: Limiting oxygen index
value: 95
unit: '% oxygen'
bound: lower
scope: material
conditions:
test_standard: ASTM D2863
sheet_note: printed as greater than 95 percent
method: Typical value printed in a supplier material data sheet
status: ground
note: The same sheet lists a UL94 flame rating of V-0 and a heat of combustion of 2,200 Btu/lb. This is a ground flammability screen in air, not the NASA-STD-6001 crew-safety test.
source: plasticsintl
where: 'Property table (Thermal section: Limiting Oxygen Index, Flame Rating)'
corrosion:
- environment: Atomic oxygen in low Earth orbit
headline: Atomic oxygen eroded PTFE about twenty times more slowly than Kapton H on the ISS.
effect: 'On the MISSE 2 flight PTFE had an erosion yield of 1.42e-25 cm3/atom, against 3.00e-24 for Kapton H and 2.99e-24 for PEEK in the same table. Other fluoropolymers were similar: FEP 2.00e-25 and PFA 1.73e-25.'
rating: low
conditions:
flight: MISSE 2, 3.95 yr, fluence 8.43e21 atoms/cm2
source: banks2008
where: Table I
- environment: Heat above 300 degC (decomposition)
headline: Overheated PTFE gives off toxic fumes.
effect: A PTFE safety data sheet says heating above 300 degC may release a fine particulate fume and, above 400 degC, decomposition products that can cause pulmonary inflammation, haemorrhage or oedema. Combustion or thermal decomposition gives very toxic and corrosive vapours such as hydrogen fluoride (HF) and carbonyl fluoride (COF2).
rating: severe
conditions:
trigger: overheating or burning
worst_case: poor ventilation or confined spaces
source: utd-sds
where: Sections 3.1 to 3.6, 5.2 and 5.3
- environment: Chemicals and water
headline: The sheet says PTFE does not dissolve in water or organic solvents, but no corrosion test was opened.
effect: The semi-finished PTFE safety data sheet lists solubility as 'Not in water or in organic solvent' and the product as stable at normal temperatures and storage conditions. Suppliers describe PTFE as chemically resistant, but no quantitative chemical-resistance table was opened for this profile.
rating: unknown
conditions:
basis: manufacturer safety data sheet, semi-finished PTFE products
source: utd-sds
where: Sections 9 and 10.1
risks:
hazards:
- text: 'Manufacturer safety data sheet (GAPI s.r.l., semi-finished PTFE, emission date 12/02/2007): the main hazard is inhaling fumes from overheating or burning. Heating above 300 degC may liberate a fine particulate fume that causes polymer fume fever, a flu-like illness with fever, chills, nausea and chest tightness. Symptoms are often delayed 4 to 24 hours and last 24 to 48 hours.'
ghs: []
source: utd-sds
where: Sections 3.1 to 3.3
- text: Above 400 degC, decomposition products may cause pulmonary inflammation, haemorrhage or oedema, particularly in poor ventilation or confined spaces. The sheet gives exposure limits for hydrofluoric acid (TLV 2.6 mg/m3) and carbonyl fluoride (TLV 5.4 mg/m3) during thermal decomposition.
ghs: []
source: utd-sds
where: Sections 3.4, 3.5 and 8.1
- text: The solid is not classified as hazardous for transport, is described as not carcinogenic and as not toxic if swallowed. If a flame is applied it ignites but combustion stops when the flame is removed. Hydrogen fluoride fumes from a fire can react with water to form hydrofluoric acid.
ghs: []
source: utd-sds
where: Sections 4.4, 5.2, 5.3, 11.2 and 14.1
failure_risks:
- mode: Loss of strength and ductility under ionizing radiation
trigger: Absorbed doses of one to two megarads in air, or 8 megarads in high vacuum
consequence: In air Teflon TFE is quickly degraded and becomes useless after one or two megarads; in vacuum it loses 88 percent of its original elongation at 8 megarads. The primary effect is chain breaking, which lowers molecular weight and makes the plastic brittle.
severity: high
source: nasa-tnd4553
where: Section on radiation resistance
- mode: Surface cracking of ePTFE cable insulation on the ISS (predicted)
trigger: 10-year mission with thermal cycling from -100 to 130 degC and ionizing radiation
consequence: A NASA Glenn analysis predicts an extremely embrittled front surface with cracks under any given strain, and microscopic cracks starting very early in the mission to a depth of about 0.030 cm after 10 years. This is a ground-based prediction, not a flight failure.
severity: moderate
source: degroh2005
where: Research summary, last paragraphs
- mode: Brittleness at hydrogen temperature
trigger: Cooling from room temperature to 20 K
consequence: At 2 mm/min strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K, and the sheet contracted by about 1.7 percent between 295 K and 20 K.
severity: moderate
source: wang2024
where: Tables 1 and 3; Section 3.2
side_effects:
- text: Irradiated polymers, almost without exception, release gaseous substances that may corrode spacecraft parts. In the report's mirror tests, vacuum-deposited copper and aluminium mirrors were sealed in ampoules with irradiated insulation, including Teflon TFE, and examined for corrosion.
affects: Nearby optics and metal surfaces
source: nasa-tnd4553
where: Section on corrosion of mirrors by evolved gases; Figures 1 and 2 (captions not read in detail, so no result for the Teflon TFE ampoules is stated)
- text: NASA Glenn describes PTFE as known to be significantly more susceptible to radiation degradation than FEP.
affects: Choice between PTFE and FEP for exposed insulation
source: degroh2005
where: Research summary, paragraph on the mobile transporter cable
handling:
- text: Use usual protective clothing; avoid using the material at high temperature (the sheet says 280 degC) and take care to prevent inhalation of fume. No smoking while handling. Prevent burns from contact with hot material, hot surfaces and flames.
source: utd-sds
where: Sections 7.1, 7.2 and 10.2
- text: Store at normal temperatures; the product is stable under normal storage conditions. Treatment and disposal must follow local regulations, and recycling is suggested if possible.
source: utd-sds
where: Sections 10.1 and 13
mitigations:
- text: Use local exhaust ventilation to remove vapours and fumes. Wear safety glasses, heat-resistant clothing and footwear, and a face shield if molten polymer might splash. In a fire, use self-contained breathing apparatus and full protective equipment.
source: utd-sds
where: Sections 5.2, 8.2 and 8.3
uses:
- application: electronics-and-chips
device: Trailing umbilical cable insulation of the ISS Mobile Transporter (railcar), made of expanded PTFE
example: The cable outer jacket is six layers of expanded PTFE, about 43 mils thick after fabrication, with an inner core 7 to 10 mils thick; it has a 10-year mission life and was installed on the S0 truss during STS-110 in April 2002.
source: degroh2005
where: Research summary, paragraph on the mobile transporter
- application: electronics-and-chips
device: Spacecraft hook-up wire insulation (Teflon TFE and FEP)
example: NASA's 1968 selection guide compares Teflon TFE and FEP against polyolefin insulations for spacecraft wire, rating outgassing, radiation resistance and weight as the most important criteria.
source: nasa-tnd4553
where: Abstract; Table 1
- application: cryogenic-fuel
device: Candidate seal or liner material for liquid-hydrogen systems (ground tensile tests only)
example: Tensile and thermal-contraction tests at room temperature, 77 K and 20 K were run on PTFE, PEEK and UHMWPE to judge thermoplastics as alternatives to metal seals in cryogenic fuel systems.
source: wang2024
where: Abstract and Section 1
- application: electronics-and-chips
device: PTFE film flight sample on the exterior of the ISS (MISSE 2 PEACE Polymers experiment)
example: PTFE was one of 40 polymers flown to measure atomic oxygen erosion; the passport misse2-ptfe records the same exposure.
source: banks2008
where: Abstract and Table I
supply:
- subject: Fluorine feedstock (fluorspar, calcium fluoride)
producers:
- {country: China, share_percent: 60.0, year: 2025}
- {country: Mexico, share_percent: 15.0, year: 2025}
- {country: Mongolia, share_percent: 15.0, year: 2025}
- {country: South Africa, share_percent: 4.1, year: 2025}
recycling: "USGS: synthetic fluorspar may be produced from neutralization of waste in uranium enrichment, petroleum alkylation and stainless-steel pickling, though impurities constrain its use. Primary aluminum producers recycle HF and fluorides from smelting."
substitutes: ["USGS: fluosilicic acid from phosphate rock has been used as an alternative to fluorspar in making AlF3 and HF (about 73,000 tons of fluorspar equivalent was recovered in 2025)."]
source: usgs-mcs2026-fluorspar
where: "World Mine Production and Reserves table, 2025e. Shares are calculated by Space Mushroom against the printed world total of 10,000 thousand t; the listed rows sum to 10,235, so shares are approximate. Recycling and Substitutes sections. Context: acid-grade fluorspar is mostly used to make anhydrous HF, the primary feedstock for fluoropolymers. US imports 2021-24 came from Mexico 64 percent, Vietnam 12 percent, China 10 percent, South Africa 9 percent; US net import reliance was 100 percent in 2025e."
- subject: PTFE resin producers
producers: []
source: wiki-ptfe
where: "Wikipedia PTFE page: Chemours is named as the maker of the PTFE-based Teflon brand. Daikin (Neoflon) and AGC (Fluon) were named in the brief, but their fetched Wikipedia pages do not state that they make PTFE, so they are not listed. No country shares for PTFE resin makers were found."
documents:
- title: 'Mineral Commodity Summaries 2026: Fluorspar (USGS)'
type: report
url: https://pubs.usgs.gov/periodicals/mcs2026/mcs2026-fluorspar.pdf
year: 2026
- title: 'NASA/TM-2008-215490: Atomic Oxygen Erosion Yield Predictive Tool for Spacecraft Polymers in Low Earth Orbit'
type: report
url: https://ntrs.nasa.gov/citations/20090011780
year: 2008
- title: 'NASA TN D-4553: Criteria for Selection of Wire Insulations for Use in Space Applications'
type: report
url: https://ntrs.nasa.gov/citations/19680018792
year: 1968
- title: 'NASA RP-1124 Rev. 3: Outgassing Data for Selecting Spacecraft Materials'
type: report
url: https://ntrs.nasa.gov/citations/19940017416
year: 1993
- title: Hubble Space Telescope Degradation Data Used for Ground-Based Durability Projection of Insulation on the International Space Station (NASA Glenn research summary)
type: report
url: https://ntrs.nasa.gov/citations/20050192335
year: 2005
- title: Evaluating the potential of thermoplastic polymers for cryogenic sealing applications (arXiv preprint)
type: paper
url: https://arxiv.org/abs/2406.01165
year: 2024
- title: 'Safety data sheet: semi-finished PTFE products (GAPI s.r.l.)'
type: sds
url: https://cores.research.utdallas.edu/files/2023/04/PTFE-MSDS.pdf
year: 2007
- title: The Effect of Nuclear Radiation Exposure to RT/duroid PTFE-Based Composites (Rogers Corporation)
type: datasheet
url: https://www.RogersCorp.com/-/media/project/rogerscorp/documents/advanced-electronics-solutions/english/properties---detailed-characteristics/the-effect-of-exposure-of-rt-duroid-ptfe-based-composites-to-nuclear-radiation.pdf
year: 2023
gaps:
- No thermal conductivity value for PTFE was opened and read; search snippets mentioned 0.20 and 0.34 W/(m K) from other datasheets but those pages were not read, so none is entered.
- No NASA outgassing database (outgassing.nasa.gov) entry was queried. The outgassing values come from NASA RP-1124 Revision 3 (1993), which lists finished PTFE products (tubing, wire insulation), not a bulk virgin-resin specimen. The database's current value for bulk PTFE was not read.
- No PTFE ultraviolet or vacuum-ultraviolet exposure result was found with a number. The NASA Goddard EOIM-III comparison report that was opened covers silvered Teflon (FEP-type) and not PTFE.
- No flown PTFE mechanical-property result (strength or elongation after orbital exposure) was found; the ISS mobile transporter cable result is a ground-based prediction in a short NASA research summary.
- No gamma or proton dose-versus-property curve for PTFE from a primary paper was opened; radiation numbers come from a 1968 NASA guide and a vendor summary of older literature, and the type of radiation behind the 8 Mrad figure is not stated in the NASA passage.
- No friction or wear value in vacuum was found; the friction values are in air.
- No PubChem compound record or ECHA/GHS classification for PTFE was opened, so hazards rest on one manufacturer safety data sheet from 2007 and carry no GHS codes. Other PTFE safety data sheets seen only in search snippets were not entered.
- 'Not entered: a quantitative chemical-resistance table, water absorption, the USGS critical-mineral status of fluorspar, and the trade-name or filled-PTFE grades.'
- "Daikin and AGC were named in the brief, but their fetched Wikipedia pages do not state that they make PTFE, so they are not listed as PTFE producers."
- The grade and manufacturer of the PTFE sheet in the Southampton preprint is not stated, and the Proto Labs, Plastics International and GAPI figures are supplier typical values, not certified grade data.
sources:
usgs-mcs2026-fluorspar:
title: Mineral Commodity Summaries 2026, Fluorspar (U.S. Geological Survey)
id: USGS MCS 2026, February 2026
url: https://pubs.usgs.gov/periodicals/mcs2026/mcs2026-fluorspar.pdf
year: 2026
kind: report
license: public domain (USGS)
wiki-ptfe:
title: Polytetrafluoroethylene (Wikipedia)
id: Wikipedia article, accessed 2026-10-19; synthesis and manufacturer sections
url: https://en.wikipedia.org/wiki/Polytetrafluoroethylene
year: 2026
kind: web
license: CC BY-SA 4.0
nist-atomic-weights:
title: Atomic Weights and Isotopic Compositions for All Elements (NIST)
id: NIST composition tables, accessed 2026-10-19
url: https://physics.nist.gov/cgi-bin/Compositions/stand_alone.pl?ele=&all=all&ascii=html
year: 2026
kind: database
license: public domain (NIST)
utd-sds:
title: 'Safety Data Sheet: Semifinished PTFE Products (GAPI s.r.l.; copy hosted by UT Dallas core facilities)'
id: PTFE Rev. 01, emission date 12/02/2007
url: https://cores.research.utdallas.edu/files/2023/04/PTFE-MSDS.pdf
year: 2007
kind: datasheet
license: manufacturer document, linked not reproduced
protolabs:
title: 'Material data sheet: PTFE (Teflon), CNC machining (Proto Labs)'
id: Proto Labs document 2026-026
url: https://www.protolabs.com/media/nrknfrcm/2026-026-cnc-material-data-sheet_ptfe-teflon.pdf
year: 2026
kind: datasheet
license: supplier document, linked not reproduced
plasticsintl:
title: Teflon PTFE (Polytetrafluoroethylene) data sheet (Plastics International)
id: Plastics International PTFE data sheet
url: https://www.plasticsintl.com/media/trshlm53/ptfe-data-sheet.pdf
year: 2023
kind: datasheet
license: supplier document, linked not reproduced
banks2008:
title: Atomic Oxygen Erosion Yield Predictive Tool for Spacecraft Polymers in Low Earth Orbit
id: NASA/TM-2008-215490, NTRS 20090011780
url: https://ntrs.nasa.gov/citations/20090011780
year: 2008
kind: report
license: public domain (NASA)
nasa-tnd4553:
title: Criteria for Selection of Wire Insulations for Use in Space Applications (V. Krueger)
id: NASA TN D-4553, NTRS 19680018792
url: https://ntrs.nasa.gov/citations/19680018792
year: 1968
kind: report
license: public domain (NASA)
rp1124:
title: Outgassing Data for Selecting Spacecraft Materials (Campbell and Scialdone)
id: NASA Reference Publication 1124, Revision 3, NTRS 19940017416
url: https://ntrs.nasa.gov/citations/19940017416
year: 1993
kind: database
license: public domain (NASA)
degroh2005:
title: Hubble Space Telescope Degradation Data Used for Ground-Based Durability Projection of Insulation on the International Space Station
id: NASA Glenn research summary, NTRS 20050192335 (de Groh, Banks, Dever, Hodermarsky)
url: https://ntrs.nasa.gov/citations/20050192335
year: 2005
kind: report
license: public domain (NASA)
wang2024:
title: 'Evaluating the potential of thermoplastic polymers for cryogenic sealing applications: strain rate and temperature effects'
id: arXiv:2406.01165 (pre-final version)
url: https://arxiv.org/abs/2406.01165
year: 2024
kind: paper
license: CC BY-NC-ND 4.0
rogers-radiation:
title: The Effect of Nuclear Radiation Exposure to RT/duroid PTFE-Based Composites
id: Rogers Corporation publication 92-293, revised 081123
url: https://www.RogersCorp.com/-/media/project/rogerscorp/documents/advanced-electronics-solutions/english/properties---detailed-characteristics/the-effect-of-exposure-of-rt-duroid-ptfe-based-composites-to-nuclear-radiation.pdf
year: 2023
kind: web
license: manufacturer document, linked not reproduced
license: CC-BY-4.0
updated: '2026-10-17'
review:
status: draft
method: assistant
checked_values: 26
unreachable: 2
caveats: 8
note: Written by an AI assistant on 2026-10-17. All values were read in text extracted from the downloaded source PDFs (NASA TM, TN D-4553 and RP-1124, the Southampton preprint, the Proto Labs, Plastics International, GAPI and Rogers documents). RP-1124 is an OCR scan, so its PTFE rows were read from OCR text. 2 sources were not usable (the NASA outgassing database search page and a PubChem PTFE record). 8 values carry caveats noted in the file. No values were taken from memory.
story:
recipe:
line: "PTFE is made by free-radical polymerization of one monomer, tetrafluoroethylene (TFE, C2F4), initiated with persulfate such as potassium or ammonium persulfate (Wikipedia). Granular PTFE is made by suspension polymerization in water with agitation and often a surfactant; PTFE is also made by emulsion polymerization, where a surfactant keeps the polymer dispersed in water. TFE can explosively decompose to tetrafluoromethane and carbon, so the reaction needs special apparatus to prevent hot spots."
parts:
- {name: Carbon, symbol: C, atoms: 2, atomic_weight: 12.011, role: "The two backbone carbons of each repeat unit, bonded to each other."}
- {name: Fluorine, symbol: F, atoms: 4, atomic_weight: 18.998, role: "Two fluorines on each backbone carbon."}
risk_groups:
- title: For people
level: 2
verdict: Safe as a solid; toxic fumes if overheated
lead: The solid is described as not toxic, but heating PTFE above 300 °C can make you ill and above 400 °C can injure the lungs.
points:
- label: The solid
line: A manufacturer safety data sheet (emission date 12/02/2007) says the solid is not classified as hazardous for transport, is not carcinogenic and is not toxic if swallowed. It ignites if a flame is applied, but combustion stops when the flame is removed.
- label: Polymer fume fever
line: Heating PTFE above 300 °C may release a fine fume that causes polymer fume fever, a flu-like illness with fever, chills, nausea and chest tightness. Symptoms are often delayed 4 to 24 hours and last 24 to 48 hours.
- label: Hotter than 400 °C
line: Above 400 °C the decomposition products may cause pulmonary inflammation, haemorrhage or oedema, especially in poor ventilation or confined spaces. Combustion gives very toxic and corrosive vapours such as hydrogen fluoride and carbonyl fluoride.
- title: If it fails
lead: These results come from a 1968 NASA guide, a NASA Glenn prediction and laboratory tests, not from a reported failure of a flown PTFE part.
points:
- label: Under radiation
line: NASA TN D-4553 says Teflon TFE irradiated in air becomes useless after one or two megarads, and in high vacuum loses 88 percent of its elongation at 8 megarads. Radiation breaks the long molecular chains, so the plastic turns brittle.
- label: In orbit
line: A NASA Glenn study of the expanded PTFE cable on the ISS predicts a badly embrittled front surface, with cracks starting early and reaching about 0.030 cm deep after a 10-year mission. This is a ground-based prediction.
- label: At hydrogen temperature
line: In tensile tests at 2 mm/min, PTFE strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K, so the sheet went from stretchy to brittle.
- title: Handling and storage
points:
- label: Keep it cool
line: The safety data sheet advises against using the material at high temperature (it says 280 °C), taking care to prevent inhaling fume, and not smoking while handling it.
- label: Ventilate
line: Use local exhaust ventilation to remove fumes. In a fire wear self-contained breathing apparatus, because hydrogen fluoride fumes can react with water to form hydrofluoric acid.
- label: Waste
line: The sheet says the solid is stable in normal storage and suggests recycling where possible, and disposal must follow local regulations.
why: Polytetrafluoroethylene (PTFE) is a polymer, a material made of very long chains of repeating units. Each unit is two carbon atoms each holding two fluorine atoms, written (-CF2-CF2-). Fluorine bonds very tightly to carbon and the fluorine coats the chain like a smooth sheath, which is why PTFE is famously slippery, chemically inert and a very good electrical insulator. A supplier sheet gives a density of about 2.17 g/cm3 (dense for a plastic), a dielectric constant of 2.1 and a volume resistivity of 10^17 to 10^18 ohm cm. PTFE melts at about 327 °C and a supplier lists a working range from -200 °C to +260 °C. The price of that tight bonding is that the chain is held together only weakly from one chain to the next, so PTFE is soft (23 to 27 MPa tensile strength) and, unlike most polymers, it is sensitive to ionizing radiation. In low Earth orbit it survives atomic oxygen well, but radiation snips the chains and leaves it brittle.
uses:
- where: ISS railcar cable
line: The trailing umbilical cables of the ISS Mobile Transporter use an outer jacket of six layers of expanded PTFE, about 43 mils thick, with an inner core of 7 to 10 mils. The cable has a 10-year mission life and was installed in April 2002.
- where: Spacecraft wire insulation
line: NASA's 1968 selection guide compared Teflon TFE and FEP with polyolefin insulations for spacecraft wire, ranking outgassing, radiation resistance and weight as the most important criteria.
- where: Tested on the ground for hydrogen systems
line: Researchers at Southampton tested PTFE in tension at room temperature, 77 K and 20 K to judge it as an alternative to metal seals in cryogenic fuel systems. These were laboratory tests, not a seal in service.
- where: Flown on the ISS as film
line: PTFE film was one of 40 polymers flown on the exterior of the ISS in the MISSE 2 experiment to measure atomic oxygen erosion over 3.95 years.
can_do:
- label: Atomic oxygen
value: 1.42e-25 cm3/atom
line: On the MISSE 2 flight PTFE eroded at 1.42 × 10⁻²⁵ cm³/atom, at a fluence of 8.43e21 atoms/cm², against 3.00 × 10⁻²⁴ for Kapton H in the same table.
- label: Outgassing
value: 0.00% in the NASA listing
line: Outgassing is the release of trapped gases and volatile compounds in vacuum, which can then condense on optics and sensors. NASA's outgassing compilation lists a PTFE tubing product at 0.00% total mass loss (TML) and 0.00% condensable material (CVCM) after 24 hours at 125 °C in vacuum, and a PTFE wire insulation at 0.01% and 0.00%. These are finished products, not bulk resin.
- label: Heat
value: Melts at 327 °C
line: A safety data sheet gives a melting point of 327 to 335 °C, and a supplier lists a service range of -200 °C to +260 °C. NASA's 1968 guide lists 260 °C as the maximum continuous service temperature of Teflon TFE wire insulation.
- label: Electrical insulation
value: 10^17 to 10^18 ohm cm
line: A supplier sheet gives a volume resistivity of 10^17 to 10^18 ohm cm, a dielectric strength of 30 to 45 kV/mm (0.5 mm specimen, ASTM D149) and a dielectric constant of 2.1.
- label: Low temperature
value: 86.22 MPa at 77 K
line: In tensile tests at 2 mm/min PTFE reached 18.15 MPa at room temperature, 86.22 MPa at 77 K and 82.32 MPa at 20 K. Strain at break fell to 4.44 percent at 77 K and 2.51 percent at 20 K, so it is much stronger but brittle when cold.
compare: In low Earth orbit PTFE eroded at 1.42 × 10⁻²⁵ cm³/atom, against 2.99 × 10⁻²⁴ for PEEK and 3.00 × 10⁻²⁴ for Kapton H in the same flight table; FEP measured 2.00 × 10⁻²⁵. In a room-temperature tension test at 2 mm/min PTFE reached 18.15 MPa, against 99.55 MPa for PEEK and 31.99 MPa for UHMWPE in the same study, and at 77 K it reached 86.22 MPa against 198.14 MPa for PEEK. For radiation, NASA Glenn describes PTFE as significantly more susceptible to radiation degradation than FEP.
handling:
- The solid is not classified as hazardous for transport, but never heat it above 300 °C without ventilation.
- Fumes from overheated PTFE cause polymer fume fever; above 400 °C they can injure the lungs.
- Do not smoke while handling it, and use local exhaust ventilation where it is heated.
- Fire gives hydrogen fluoride fumes, so use self-contained breathing apparatus.
good_for:
- Atomic oxygen resistance. The MISSE 2 erosion yield was 1.42 × 10⁻²⁵ cm³/atom, far below Kapton H at 3.00 × 10⁻²⁴.
- Electrical insulation. A supplier sheet gives a dielectric constant of 2.1 and a volume resistivity of 10^17 to 10^18 ohm cm.
- Low outgassing. NASA's listing shows PTFE tubing at 0.00% total mass loss and 0.00% condensable material after 24 hours at 125 °C.
- A very wide temperature range. A supplier lists -200 °C to +260 °C.
watch_out:
- Radiation. NASA TN D-4553 says Teflon TFE becomes useless after one or two megarads in air, and loses 88 percent of its elongation at 8 megarads in vacuum.
- Softness. Tensile strength is only 23 to 27 MPa at room temperature.
- Brittle when cold. Strain at break fell from 302.96 percent at room temperature to 2.51 percent at 20 K.
- Overheating. Heating above 300 °C releases fumes, and above 400 °C toxic gases including hydrogen fluoride.
verdict: PTFE is a slippery, low-outgassing, electrically excellent plastic that resists atomic oxygen far better than most polymers, but it is soft and ionizing radiation breaks it down at doses of a few megarads. It suits shielded or short-exposure uses such as cable insulation, not a long-lived exposed surface. Only the MISSE 2 erosion yield here is a flight result; the radiation and cold figures are ground tests or literature summaries.
compare_rows:
- label: Density
benchmark: density
scope: material
- label: Max service temp
benchmark: max_service_temp
scope: material
- label: Glass transition temperature
benchmark: glass_transition_temperature
scope: material
References
Every number above carries a reference number. Click one to see the source and where in it the value comes from.