Ethylene propylene diene monomer rubber (EPDM) EPDM

Terpolymer of ethylene, propylene and a diene (ethylidene norbornene, dicyclopentadiene or vinyl norbornene). Saturated polyethylene-type backbone with a small diene comonomer that provides the cure sites.

Also known as ASTM D1418

EPDM (ethylene propylene diene monomer) is a synthetic terpolymer rubber made from ethylene, propylene and a small amount of a diene that carries the cure sites.

11 sources · Updated 2026-10-26 · CC BY 4.0

Evidence level

2 of 5

Lab-measured

Temperature

-30 to 150 °C

Cold

-57 °C

Hardness and strength

70 to 71 Shore A

Compression set

13 to 38%

Outgassing

Depends on part and bakeout

Recipe, share of the weight

  • not statedEthylene
  • not statedPropylene
  • not statedDiene

Best for

Seals for hot water, steam, ozone and weathering, and for glycol or silicone brake fluids (Polymax, Parker)

Weakest at

Petroleum lubricants (Parker says it deteriorates in them), and UV exposure, which crosslinks and oxidises the rubber in the one UV-aged study read here

Risk at a glance

  • People No data. No hazard data recorded
  • If it fails Severe. Deterioration in petroleum lubricants
  • Corrosion Severe. EPDM deteriorates in petroleum lubricants, a key limit for this rubber.

Quick facts: EPDM

Key properties of EPDM
PropertyValueBasis
Density1.14 to 1.19 g/cm³2 sourced values across conditions
Tensile strength10.5 to 17 MPa2 sourced values across conditions
Thermal expansion (CTE)49.4 ppm/K1 sourced value
Maximum service temperature125 to 260 °C7 sourced values across conditions

What is the density of Ethylene propylene diene monomer rubber (EPDM)?

Ethylene propylene diene monomer rubber (EPDM) has a density of 1.14 to 1.19 g/cm³. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the coefficient of thermal expansion of Ethylene propylene diene monomer rubber (EPDM)?

Ethylene propylene diene monomer rubber (EPDM) has a coefficient of thermal expansion of 49.4 ppm/K. The source and test conditions are listed in the properties table on this page.

What is the tensile strength of Ethylene propylene diene monomer rubber (EPDM)?

Ethylene propylene diene monomer rubber (EPDM) has a tensile strength of 10.5 to 17 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the maximum service temperature of Ethylene propylene diene monomer rubber (EPDM)?

Ethylene propylene diene monomer rubber (EPDM) has a maximum service temperature of 125 to 260 °C. The range covers 7 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is Ethylene propylene diene monomer rubber (EPDM) used for?

Uses recorded in the sources include O-ring seals in brake systems that use glycol (DOT 3 and 4) or silicone (DOT 5) fluids; O-rings and gaskets in vacuum equipment, tested to the ASTM E 595 outgassing method.

Why it exists

EPDM is a rubber that stays elastic in hot water, steam and weather. Parker's handbook gives it up to 150 °C in water and steam and cold flexibility to about -57 °C, and says it is particularly useful in glycol and silicone brake fluids. It is weak in petroleum lubricants, which Parker says it deteriorates in.

Where it's used

O-ring seals in brake systems

Polymax says EPDM is particularly useful in brake systems with glycol (DOT 3 and 4) or silicone (DOT 5) fluids. Parker says it is useful with phosphate-ester hydraulic fluids.

Vacuum equipment O-rings and gaskets

NASA's outgassing database lists EPDM O-rings and gaskets tested to ASTM E 595. Their values are not recorded in this file (see gaps). No spacecraft flight use was named.

Recipe

Terpolymer of ethylene, propylene and a diene (ethylidene norbornene, dicyclopentadiene or vinyl norbornene). Saturated polyethylene-type backbone with a small diene comonomer that provides the cure sites.

EPDM is a terpolymer of ethylene, propylene and a diene. The diene (ethylidene norbornene, dicyclopentadiene or vinyl norbornene, about 2 to 12% in commercial grades per Wikipedia) carries the cure sites, so the rubber crosslinks by sulphur vulcanisation or by peroxide. Commercial compounds are filled with carbon black or mineral filler and extended with plasticisers. The UV-aged study used an aluminium trihydrate filled, peroxide-cured compound.

What EPDM is made of
IngredientShare of the weightWhat it does
Ethylene not stated Main monomer; with propylene it forms the saturated polyethylene-type backbone.
Propylene not stated Second main monomer; it breaks up the polyethylene crystallinity so the rubber stays elastic.
Diene not stated Cure site. Its double bonds take part in sulphur or peroxide crosslinking.

Weight shares are as printed in the sources.

What it can do

Temperature

-30 to 150 °C

Polymax gives -30 to 125 °C for the sulphur-cured 70 ShA grade and -30 to 150 °C for the peroxide-cured grade. Parker gives up to 150 °C in water and steam, with special compounds to 260 °C in hot water and steam.

Cold

-57 °C

Parker gives cold flexibility down to about -57 °C. The peroxide-cured Polymax grade is rated to -42 °C by ISO 2921.

Hardness and strength

70 to 71 Shore A

The 70 Shore A grades have a tensile strength of 10.5 to 17 MPa and an elongation of 220 to 255%.

Compression set

13 to 38%

The peroxide-cured and EP70 grades keep 13% set after the test. The sulphur-cured grade keeps 38% after 22 h at 125 °C (ASTM D 395 B).

Outgassing

Depends on part and bakeout

NASA's database rows for EPDM O-rings differ before and after bakeout, and between manufacturers. The values are not recorded in this file because the database page loads them by script (see gaps).

How it compares

EPDM is a general-purpose elastomer for hot water, steam, ozone and brake-fluid seals. Its best service is in water and steam, where Parker says ethylene propylene is generally superior to fluorocarbon. It is cold-flexible, but Parker says it deteriorates in petroleum lubricants. No comparison table with other elastomers was built in this run.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementEPDMCOCHDPEPMP (TPX)PEPKPPPVCUHMWPE
Physical and electrical
Hardness, sulphur-cured 70 ShATypical value from the supplier datasheet71 Shore Ano datano datano datano datano datano datano datano data
Specific gravity, sulphur-cured 70 ShATypical value from the supplier datasheet1.19 g/cm³1020 kg/m30.959 g/cm³833 kg/m30.959 g/cm³0.948 g/cm³0.9 g/cm³1.32 g/cc0.93 g/cc
Hardness, peroxide-cured 70 ShATypical value from the supplier datasheet70 Shore Ano datano datano datano datano datano datano datano data
Specific gravity, peroxide-cured 70 ShATypical value from the supplier datasheet1.14 g/cm³1020 kg/m30.959 g/cm³833 kg/m30.959 g/cm³0.948 g/cm³0.9 g/cm³1.32 g/cc0.93 g/cc
Temperature behavior
DMA transition temperature, new UV-weathering EPDM housing-42 °C19134 °Cno datano datano datano datano datano datano data
DMA transition temperature, after 2160 h UV ageing-37 °C20134 °Cno datano datano datano datano datano datano data
TGA DTG peak temperature, new filled EPDMThermogravimetric analysis, DTG peak temperature365 °C21no datano datano datano datano datano datano datano data
TGA DTG peak temperature, after 2160 h UV ageingThermogravimetric analysis, DTG peak temperature354 °C22no datano datano datano datano datano datano datano data
Other measurements
Heat resistance in water and steam (general EPDM)150 °C1no data180 °Fno datano datano datano data< 60 °C82.2 °C
Hot water and steam with special compounds260 °C2no data180 °Fno datano datano datano data< 60 °C82.2 °C
Cold flexibility (general EPDM)-57 °C3no datano datano datano datano datano datano datano data
Linear thermal expansion coefficient, 24 to 191 °C8.9×10^-5 in/in/°F4no datano data1.17×10^-4 cm/cm°Cno datano datano data54 µm/m-°C198 µm/m-°C
Weight loss in vacuum, E0515-80 ethylene propylene compound0.39 %5no datano datano datano datano datano datano datano data
Weight loss in vacuum, E0692-75 ethylene propylene compound0.76 %6no datano datano datano datano datano datano datano data
Weight loss in vacuum, E0529-60 ethylene propylene compound0.92 %7no datano datano datano datano datano datano datano data
Compression set after gamma dose, E0740-75 ethylene propylene28.6 %8no datano datano datano datano datano datano datano data
Compression set after gamma dose, E0515-80 ethylene propylene46.6 %9no datano datano datano datano datano datano datano data
Temperature for 90% set after 1000 h, E0740-75 ethylene propyleneParker radiation table, footnote 2177 °Cno data180 °Fno datano datano datano data< 60 °C82.2 °C
Temperature for 90% set after 1000 h, E0515-80 ethylene propyleneParker radiation table, footnote 2149 °Cno data180 °Fno datano datano datano data< 60 °C82.2 °C
Operating temperature range, sulphur-cured 70 ShA O-ring125 °C10no data180 °Fno datano datano datano data< 60 °C82.2 °C
Operating temperature range, lower limit, sulphur-cured 70 ShA O-ring-30 °C11no datano datano datano datano datano datano datano data
Low temperature resistance, sulphur-cured 70 ShATypical value from the supplier datasheet-40 °Cno datano datano datano datano datano datano datano data
Tensile strength, sulphur-cured 70 ShATypical value from the supplier datasheet10.5 MPa46 MPano data25 MPa21 MPa19 MPano data33 MPa40 MPa
Elongation at break, sulphur-cured 70 ShATypical value from the supplier datasheet255 %120 %> 400 %22 %400 %25 %no data140 %300 %
Compression set, sulphur-cured 70 ShATypical value from the supplier datasheet38 %12no datano datano datano datano datano datano datano data
Tear resistance, sulphur-cured 70 ShATypical value from the supplier datasheet49 N/mmno datano datano datano datano datano datano datano data
Operating temperature range, peroxide-cured 70 ShA O-ring150 °C13no data180 °Fno datano datano datano data< 60 °C82.2 °C
Operating temperature range, lower limit, peroxide-cured 70 ShA O-ring-30 °C14no datano datano datano datano datano datano datano data
Low temperature resistance, peroxide-cured 70 ShATypical value from the supplier datasheet-42 °C15no datano datano datano datano datano datano datano data
Tensile strength, peroxide-cured 70 ShATypical value from the supplier datasheet17 MPa46 MPano data25 MPa21 MPa19 MPano data33 MPa40 MPa
Elongation at break, peroxide-cured 70 ShATypical value from the supplier datasheet220 %120 %> 400 %22 %400 %25 %no data140 %300 %
Compression set, peroxide-cured 70 ShATypical value from the supplier datasheet13 %16no datano datano datano datano datano datano datano data
Tear resistance, peroxide-cured 70 ShATypical value from the supplier datasheet32 N/mmno datano datano datano datano datano datano datano data
Tested operating range, EP70 EPDM compound145 °C17no data180 °Fno datano datano datano data< 60 °C82.2 °C
Tested operating range lower limit, EP70 EPDM compound-45 °C18no datano datano datano datano datano datano datano data
Compression set, EP70 EPDM compoundTested value on the technical data sheet13 %no datano datano datano datano datano datano datano data

Why choose it, and why not

Good for

  • Hot water, steam and weathering seals, and brake-fluid seals in glycol or silicone fluids (Polymax and Parker).
  • Vacuum seals after bakeout: NASA's database has ASTM E 595 rows for EPDM O-rings, and the rows differ before and after bakeout (values not recorded here, see gaps).
  • Cold flexibility down to about -57 °C (Parker).

Watch out for

  • Petroleum lubricants and oils: Parker says EPDM deteriorates in them.
  • Heat ageing: 14% tensile loss and 24% elongation loss after 70 h at 125 °C (sulphur-cured grade).
  • Compression set rises with heat: 38% after 22 h at 125 °C for the sulphur-cured grade, against 13% for the peroxide-cured grade.
  • UV: a filled, peroxide-cured housing crosslinks and oxidises under UVA and its transition temperature moves from -42 °C to -37 °C after 2160 h.
  • Radiation: at 10^7 rad, E0515-80 takes a 46.6% set (Parker).

EPDM is a dependable seal for hot water, steam, ozone and brake-fluid service. It does poorly in petroleum oils and lubricants, and its vacuum outgassing depends on the part and bakeout, so each seal needs a test or a verified NASA database row.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Other names and standards

The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.

Other names and standards
SystemCodes
ASTMD1418

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Heat resistance in water and steam (general EPDM)Statement in the Parker O-Ring Handbook, EPDM sectionmedium water and/or steamnote Parker gives 204 °C (400 °F) as the maximum, with shorter life at that level—
2Hot water and steam with special compoundsStatement in the Parker O-Ring Handbook, EPDM sectionmedium hot water and steamcompound special compounds (Parker does not name them in this statement)—
3Cold flexibility (general EPDM)Statement in the Parker O-Ring Handbook, EPDM sectionbasis Parker wording is approximately -57 °C (-70 °F)—
4Linear thermal expansion coefficient, 24 to 191 °CParker table of linear thermal expansion, printed in US unitsrange 24 to 191 °C (75 to 375 °F)basis Ethylene Propylene row; printed as 8.9 x 10-5—
5Weight loss in vacuum, E0515-80 ethylene propylene compoundParker weight loss of compounds in vacuum test, which is not the ASTM E595 TML methodvacuum about 1 x 10-6 torrtime 336 htemperature 25 °C—
6Weight loss in vacuum, E0692-75 ethylene propylene compoundParker weight loss of compounds in vacuum test, which is not the ASTM E595 TML methodvacuum about 1 x 10-6 torrtime 336 htemperature 25 °C—
7Weight loss in vacuum, E0529-60 ethylene propylene compoundParker weight loss of compounds in vacuum test, which is not the ASTM E595 TML methodvacuum about 1 x 10-6 torrtime 336 htemperature 25 °C—
8Compression set after gamma dose, E0740-75 ethylene propyleneParker radiation table, compression set after exposure to gamma radiationdose 10^7 rad gamma (the PDF prints the exponent as a superscript; read as 10^7 from the table header and footnote 1)temperature room temperaturecompound E0740-75, polymer ethylene propylene—
9Compression set after gamma dose, E0515-80 ethylene propyleneParker radiation table, compression set after exposure to gamma radiationdose 10^7 rad gamma (superscript in PDF; read as 10^7 as for E0740-75)temperature room temperaturecompound E0515-80, polymer ethylene propylene—
10Operating temperature range, sulphur-cured 70 ShA O-ringOperating temperature range printed on the datasheetcure sulphur-basedgrade EPDM 70 ShA, black—
11Operating temperature range, lower limit, sulphur-cured 70 ShA O-ringOperating temperature range printed on the datasheetcure sulphur-basedgrade EPDM 70 ShA, black—
12Compression set, sulphur-cured 70 ShA—test ASTM D 395 Btime 22 htemperature 125 °C—
13Operating temperature range, peroxide-cured 70 ShA O-ringOperating temperature range printed on the datasheetcure peroxidegrade EPDM 70 ShA peroxide cured, black—
14Operating temperature range, lower limit, peroxide-cured 70 ShA O-ringOperating temperature range printed on the datasheetcure peroxidegrade EPDM 70 ShA peroxide cured, black—
15Low temperature resistance, peroxide-cured 70 ShA—test ISO 2921criterion printed as < -37 °C in the test columncure peroxide—
16Compression set, peroxide-cured 70 ShA—test ISO 815 Bcure peroxidenote time and temperature not printed in the table row—
17Tested operating range, EP70 EPDM compoundTechnical data sheet, operating temperature range, tested columncompound EP70 (EPDM), blackcolumn tested value; the required column is n/a—
18Tested operating range lower limit, EP70 EPDM compoundTechnical data sheet, operating temperature range, tested columncompound EP70 (EPDM), blackcolumn tested value—
19DMA transition temperature, new UV-weathering EPDM housingTemperature label on the tan delta plot in Fig. 3 legend, read as the DMA transitionmaterial industrial EPDM housing with aluminium trihydrate filler (Table 1 of the paper), peroxide curedtest DMA, dual cantilever, 1 Hz, 3 °C/min—
20DMA transition temperature, after 2160 h UV ageingTemperature label on the tan delta plot in Fig. 3 legendmaterial industrial EPDM housing with aluminium trihydrate filler, peroxide curedexposure UVA 340 nm, 45 °C, dry, 2160 h—
21TGA DTG peak temperature, new filled EPDM—atmosphere nitrogenheating rate 10 °C/min, 25 to 800 °Cmaterial industrial EPDM housing with aluminium trihydrate filler—
22TGA DTG peak temperature, after 2160 h UV ageing—atmosphere nitrogenheating rate 10 °C/min, 25 to 800 °Cexposure UVA 340 nm, 45 °C, 2160 h—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Hot air, 125 °C, 70 h (sulphur-cured 70 ShA) moderate Hot air ageing hardens the sulphur-cured grade and removes some strength and elongation.1
Water, 100 °C, 70 h (sulphur-cured 70 ShA) low Hot water swells the sulphur-cured grade slightly.2
Hot air, 150 °C, 70 h (peroxide-cured 70 ShA) moderate The peroxide-cured grade holds up better in hot air, losing about a quarter of its strength and elongation.3
Water, 100 °C, 70 h (peroxide-cured 70 ShA) low Hot water barely changes the peroxide-cured grade.4
Heat, 100 °C, 70 h (EP70 compound, tested) low The EP70 compound changes little after 70 h at 100 °C.5
Steam at 288 °C (550 °F), 70 h, special ethylene propylene compound E0962-90 low A special EPDM compound shows little change after long steam exposure at 288 °C.6
Petroleum lubricants in contact with the seal severe EPDM deteriorates in petroleum lubricants, a key limit for this rubber.7
UV weathering, UVA 340 nm at 45 °C, dry, up to 2160 h (filled EPDM housing) moderate UV crosslinks and oxidises the filled EPDM, and its surface becomes less water-repellent.8
Corrosion details
#EnvironmentDetailsTest conditions
1 Hot air, 125 °C, 70 h (sulphur-cured 70 ShA) After 70 h at 125 °C in air (ASTM D 573), hardness rose by 4 points, tensile strength fell 14% and ultimate elongation fell 24%. time 70 htemperature 125 °Cstandard ASTM D 573
2 Water, 100 °C, 70 h (sulphur-cured 70 ShA) After 70 h at 100 °C in water (ASTM D 471), volume rose by 2%. time 70 htemperature 100 °Cstandard ASTM D 471
3 Hot air, 150 °C, 70 h (peroxide-cured 70 ShA) After 70 h at 150 °C in air (ISO 188 B), hardness rose by 4 points, tensile strength fell 25% and ultimate elongation fell 25%. Volume fell 0.4%. time 70 htemperature 150 °Cstandard ISO 188 B
4 Water, 100 °C, 70 h (peroxide-cured 70 ShA) After 70 h at 100 °C in water (ISO 1817), hardness changed by -1 point, tensile strength by -4%, ultimate elongation by -7%, and volume rose by 1.3%. time 70 htemperature 100 °Cstandard ISO 1817
5 Heat, 100 °C, 70 h (EP70 compound, tested) After 70 h at 100 °C, hardness changed by +3 points, tensile strength by +1% and elongation by -9%. time 70 htemperature 100 °C
6 Steam at 288 °C (550 °F), 70 h, special ethylene propylene compound E0962-90 Parker says compound E0962-90 showed very little change in physical properties after 70 hours exposure to steam at 288 °C (550 °F). Parker gives no number for ordinary compounds. time 70 htemperature 288 °Ccompound E0962-90
7 Petroleum lubricants in contact with the seal Parker says that when sealing steam or water with ethylene propylene rubber, the seal will deteriorate when exposed to petroleum lubricants. Parker suggests silicone oil, glycerin or ethylene glycol when lubrication is required. basis qualitative statement, no test conditions given
8 UV weathering, UVA 340 nm at 45 °C, dry, up to 2160 h (filled EPDM housing) The paper reports a crosslinking process along weathering, oxygenated species that rise with time, and a surface contact angle that falls linearly with ageing time. The paper prints no contact-angle value. Its TGA showed no loss of thermal stability in the components. The lamps gave 0.89 W/m2/nm with no condensation, following the ASTM G154 approach the paper cites. exposure UVA 340 nm, 45 °C, dry, up to 2160 hirradiance 0.89 W/m2/nmmaterial EPDM with aluminium trihydrate filler, peroxide cured

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

No hazard classification was retrieved for the EPDM compound in this run.

Safety data
Read the safety data sheet for the specific compound before handling. None was retrieved here.

For the monomers

PubChem classifies the monomers, not the compound. Ethylene and propylene are extremely flammable gases under pressure. Ethylidene norbornene is a flammable liquid.

Ethylene
Extremely flammable gas, which may explode if heated. PubChem also lists drowsiness or dizziness (H336).
Propylene
Extremely flammable gas under pressure. PubChem lists the same H220 and H280 codes as ethylene.
Ethylidene norbornene
Flammable liquid that may be fatal if swallowed and enters airways. PubChem also lists harm if inhaled and possible skin and eye irritation.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Hardening and loss of elasticity after heat ageingmoderate severityService at 125 °C in air for 70 h (sulphur-cured grade)Tensile strength falls 14% and elongation falls 24%, with a 4-point rise in hardness
Permanent set after long compression at heatmoderate severityCompressed for 22 h at 125 °C (sulphur-cured) or the same test on the EP70 compoundSet of 38% for the sulphur-cured grade, against 13% for the peroxide-cured and EP70 grades. The seal recovers less of its shape and may leak.
Deterioration in petroleum lubricantscritical severitySeal in contact with petroleum lubricants, or lubricated with themParker says EPDM deteriorates when exposed to petroleum lubricants; use silicone oil, glycerin or ethylene glycol instead
Stiffening below the low-temperature limitmoderate severityOperation below -30 °C (sulphur-cured) or -42 °C (peroxide-cured, ISO 2921)The seal loses flexibility and may leak
Compression set after gamma dosemoderate severity10^7 rad gamma at room temperatureE0740-75 takes a 28.6% set and E0515-80 a 46.6% set, which lowers the seal's recovery
UV photo-oxidationmoderate severityUVA 340 nm at 45 °C, dry, for up to 2160 hCrosslinking and oxygenated species form, and the surface becomes less water-repellent. The transition temperature moves from -42 °C to -37 °C.

Side effects on surrounding parts

Side effects on surrounding parts
AffectsEffect
Not sourcedNo side effects found in this run.

Handling and storage

  • Read the safety data sheet for the specific EPDM compound before use. None was retrieved in this run.
  • Keep ethylene and propylene gases away from heat. PubChem's H280 says they may explode if heated.
  • Do not lubricate EPDM seals with petroleum lubricants. Parker suggests silicone oil, glycerin or ethylene glycol.

Mitigations

  • Choose a peroxide-cured compound for service up to 150 °C. Polymax rates the sulphur-cured grade to 120 °C in its text, and its operating range line says 125 °C.
  • Lubricate with silicone oil, glycerin or ethylene glycol rather than petroleum lubricants.

Supply and geography

How common the raw materials are and where they come from.

Sulphur, the curing agent for sulphur-cured EPDM

World sulphur production was 83,900 thousand t in 2024 and 84,000 thousand t in 2025 (USGS). China produced 19,000 thousand t in both years. Most sulphur is recovered from petroleum and natural gas processing.

Recycling
Not stated in the USGS summary read here.