Polyetheretherketone PEEK

(-O-C6H4-O-C6H4-CO-C6H4-)n · CAS 31694-16-3

PEEK is a stiff, heat-tolerant engineering thermoplastic.

11 sources · Updated 2026-10-17 · CC BY 4.0

Evidence level

5 of 5

Flown or field-proven

Strength and stiffness

98.0 MPa

Heat

Melts at 343 °C

Low temperature

198.14 MPa at 77 K

In orbit

Kept about 15% of its stretch

Outgassing

0.19% mass loss

Recipe, share of the weight

  • C 79.2%Carbon
  • H 4.2%Hydrogen
  • O 16.6%Oxygen

Best for

A stiff, heat-tolerant, low-outgassing structural and electrically insulating plastic (printed PEEK lost 0.19% of its mass in an outgassing test)

Weakest at

Ultraviolet and atomic-oxygen exposure in low Earth orbit (embrittled to about 15% of its original elongation on the ISS), and loss of strength between 77 K and 20 K

Risk at a glance

  • People Low. Not classified; hot PEEK burns
  • If it fails Moderate. Embrittlement in low Earth orbit
  • Corrosion Moderate. Atomic oxygen eroded PEEK at about the same rate as Kapton H polyimide on the ISS.

Quick facts: PEEK

Key properties of PEEK
PropertyValueBasis
Density1.3 g/cm³1 sourced value
Thermal conductivity0.29 W/(m·K)1 sourced value
Melting point343 °C1 sourced value

What is the density of Polyetheretherketone (PEEK)?

Polyetheretherketone (PEEK) has a density of 1.3 g/cm³. The source and test conditions are listed in the properties table on this page.

What is the thermal conductivity of Polyetheretherketone (PEEK)?

Polyetheretherketone (PEEK) has a thermal conductivity of 0.29 W/(m·K). The source and test conditions are listed in the properties table on this page.

What is the melting point of Polyetheretherketone (PEEK)?

Polyetheretherketone (PEEK) has a melting point of 343 °C. The source and test conditions are listed in the properties table on this page.

What is Polyetheretherketone (PEEK) used for?

Uses recorded in the sources include 3D-printed PEEK structure for a 2U CubeSat-class nanosatellite for low Earth orbit (design and ground tests only in the paper); PEEK film samples on the exterior of the ISS Russian Service Module (flight exposure experiment); Candidate seal or liner material for liquid-hydrogen systems (ground tensile tests only).

Why it exists

Polyetheretherketone (PEEK) is a thermoplastic, a polymer that softens when heated and can be melted and reshaped. Each repeat unit of its chain joins three benzene rings (phenylene groups) through two ether links (a carbon-oxygen-carbon bridge) and one ketone group (a carbon double-bonded to oxygen), which is where the name comes from. The rings make the chain stiff, so PEEK keeps its stiffness to high temperature. Two temperatures mark the limits. The glass transition temperature, where the disordered regions of the plastic change from glassy to rubbery, is 150 °C (midpoint) for the Victrex 450G grade, and the crystalline regions melt at 343 °C. PEEK is also electrically insulating and absorbs little water. Those properties explain why it is considered for structures and mechanisms that must stay stiff when hot, but the record collected here also shows that space ultraviolet light and atomic oxygen degrade it, so it is not a drop-in material for every orbit.

Where it's used

Printed nanosatellite structure

A paper designed a fused-filament-printed PEEK structure for a 2U CubeSat-class nanosatellite, 10 x 10 x 21 cm, for low Earth orbit. The paper reports design work and ground tests, and the space-relevant test is the outgassing measurement described below.

Flown on the ISS as film

JAXA exposed 0.4 mm PEEK film under tensile load on the exterior of the ISS Russian Service Module from October 2001 to August 2005, as a candidate for deployable structures such as large antennas, solar arrays and sails.

Tested on the ground for hydrogen systems

Researchers tested PEEK in tension at room temperature, 77 K and 20 K to judge thermoplastics as alternatives to metal seals in cryogenic fuel systems. These were laboratory tests, not a seal in service.

Tested on the ground for robots in radiation

UKAEA irradiated PEEK to 5 MGy of gamma radiation as a candidate structural polymer for remote-handling robots in fusion maintenance. This was a laboratory irradiation, not a deployment.

Recipe

(-O-C6H4-O-C6H4-CO-C6H4-)n

PEEK is made by step-growth polymerization. The disodium salt of hydroquinone, generated in situ by deprotonation with sodium carbonate, reacts with 4,4'-difluorobenzophenone by dialkylation of the bisphenolate salts (Wikipedia). The repeat unit is C19H12O3 (Wikipedia infobox formula).

What PEEK is made of
IngredientAtoms per unitShare of the weightWhat it does
Carbon C 19 79.2% Three benzene rings and the ketone carbon of each repeat unit.
Hydrogen H 12 4.2% Four hydrogens on each of the three phenylene rings.
Oxygen O 3 16.6% Two ether oxygens and one ketone oxygen per repeat unit.

Weight shares are calculated from standard atomic weights.

What it can do

Strength and stiffness

98.0 MPa

The Victrex datasheet gives a tensile yield stress of 98.0 MPa and a tensile modulus of 4000 MPa for the 450G grade, tested to ISO 527 at 23 °C. These are nominal values; a printed PEEK part in another study measured 78.0 MPa and 2.9 GPa.

Heat

Melts at 343 °C

The datasheet gives a glass transition midpoint of 150 °C and a melting temperature of 343 °C for the 450G grade. Above the glass transition the plastic is much less stiff, so useful loads are carried well below the melting point.

Low temperature

198.14 MPa at 77 K

In tensile tests at 2 mm/min the ultimate tensile strength was 99.55 MPa at room temperature, 198.14 MPa at 77 K and 114.57 MPa at 20 K. The grade of PEEK was not stated in the preprint.

In orbit

Kept about 15% of its stretch

After 46 months on the ISS, PEEK film kept its modulus and yield strength but only about 15% of its original elongation at break. Its atomic-oxygen erosion yield on the MISSE 2 flight was 2.99 × 10⁻²⁴ cm³/atom over 3.95 years at a fluence of 8.43e21 atoms/cm².

Outgassing

0.19% mass loss

Outgassing is the release of trapped gases and volatile compounds in vacuum, which can then condense on optics and sensors. A 3D-printed PEEK specimen heated at 125 °C for 24 hours in vacuum under the ECSS-Q-ST-70-02C method lost 0.19% of its mass (total mass loss, TML) and condensed 0.01% of its mass on a collector (CVCM).

How it compares

In a room-temperature tension test at 2 mm/min, PEEK reached 99.55 MPa, against 18.15 MPa for PTFE and 31.99 MPa for UHMWPE (ultra-high-molecular-weight polyethylene). At 77 K the same polymers reached 198.14, 86.22 and 129.77 MPa. In low Earth orbit, PEEK eroded at 2.99 × 10⁻²⁴ cm³/atom, almost the same as the 3.00 × 10⁻²⁴ measured for Kapton H polyimide in the same flight table, while fluoropolymers such as FEP (2.00 × 10⁻²⁵) and PTFE (1.42 × 10⁻²⁵) eroded far less. No source in this record compares PEEK with metals or composites, so no such comparison is made.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementPEEKPAIPBIPBO (Zylon)PEIPEKPEKKPESPPSPPSUPSU
Thermal behavior and safety
Melting temperature343 °C5no datano datano datano data373 °C360 °Cno data536 °Fno datano data
Thermal conductivity (average)0.29 W/(m K)60.53 W/m/K0.41 W m-1 K-1no data0.22 W/m-°C0.29 W/m/Kno datano datano datano datano data
Lifetime and stability
Total mass loss, 3D-printed PEEK (ECSS test)0.19 % mass8no datano datano datano datano datano datano datano datano datano data
Collected volatile condensable material, 3D-printed PEEK (ECSS test)0.01 % mass9no datano datano datano datano datano datano datano datano datano data
Physical and electrical
Density (crystalline), VICTREX PEEK 450G1.3 g/cm³11.41 g/cc1.276 g/cm³1.398 g/cm³1.34 g/cm³1.3 g/cm³1.29 g/cm³1370 kg/m31.36 g/cm³1.29 g/cm³1.22 g/cm³
Other measurements
Tensile modulus4000 MPa2no datano datano data2465 MPano datano datano datano datano datano data
Tensile yield stress98 MPa3no datano datano datano datano datano datano datano datano datano data
Glass transition temperature (midpoint)150 °C4no datano datano datano datano datano datano datano datano datano data
Atomic oxygen erosion2.99×10^-24 cm³/atom7no data> 2.21×10^-24 cm³/atom1.36×10^-24 cm³/atom> 3.31×10^-24 cm³/atomno datano datano datano datano data2.94×10^-24 cm³/atom
Elongation at break retained after 46 months on the ISS15 % of pristine10no datano datano datano datano datano datano datano datano datano data
Ultimate tensile strength at 77 KTensile test in a cryogenic test rig198.1 MPa11no datano datano datano datano datano datano datano datano datano data
Highest gamma dose in a tensile and nano-indentation study5 MGy12no datano datano datano datano datano datano datano datano datano data

Why choose it, and why not

Good for

  • Stiffness at temperature. The 450G datasheet gives a tensile modulus of 4000 MPa at 23 °C and a glass transition midpoint of 150 °C.
  • Low outgassing. A printed PEEK specimen lost 0.19% of its mass and condensed 0.01% in a 125 °C vacuum test.
  • Cryogenic strength. Tensile strength reached 198.14 MPa at 77 K, higher than PTFE or UHMWPE in the same test.

Watch out for

  • Ultraviolet and atomic oxygen. Film on the ISS kept only about 15% of its elongation at break after 46 months, and its atomic-oxygen erosion yield was about equal to Kapton H.
  • Very cold temperatures. Strength fell from 198.14 MPa at 77 K to 114.57 MPa at 20 K.
  • Gamma radiation. Strain at failure fell distinctly after 100 kGy in a study up to 5 MGy, though sample numbers were small.
  • Process matters. Printed PEEK was weaker than the datasheet values (78.0 MPa against 98.0 MPa), and datasheet figures are nominal.

PEEK is a stiff, heat-tolerant, low-outgassing plastic with flight exposure data on the ISS, but that data shows ultraviolet embrittlement and atomic-oxygen erosion like Kapton H. It suits parts that are shielded from the orbital surface environment, and every use above is a ground test or proof of concept except the two flight exposures.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Density (crystalline), VICTREX PEEK 450GValue listed in the manufacturer's online datasheetgrade VICTREX PEEK 450Gtest standard ISO 1183state crystallineDatasheet values are nominal and depend on part geometry and processing. A 3D-printed part measured lower, 1.244 +/- 0.025 g/cm3 (outgassing specimen) and 1.221 +/- 0.036 g/cm3 (tensile specimen) in Rinaldi et al. Table 8.
2Tensile modulusValue listed in the manufacturer's online datasheetgrade VICTREX PEEK 450Gtest standard ISO 527-1temperature 23 °CFlexural modulus in the same table is 3800 MPa (ISO 178, 23 degC).
3Tensile yield stressValue listed in the manufacturer's online datasheetgrade VICTREX PEEK 450Gtest standard ISO 527-2temperature 23 °CTensile strain at break on the same page is 25% (ISO 527-2, 23 degC).
4Glass transition temperature (midpoint)Value listed in the manufacturer's online datasheet (differential scanning calorimetry)grade VICTREX PEEK 450Gtest standard ISO 11357-2point midpointThe onset of the glass transition on the same page is 143 degC. The unirradiated film in Nakamura and Fujita measured 142.3 degC by DSC (Table 3).
5Melting temperatureValue listed in the manufacturer's online datasheet (differential scanning calorimetry)grade VICTREX PEEK 450Gtest standard ISO 11357-3The Victrex safety data sheet also lists a melting point of 343 degC and a decomposition temperature above 450 degC.
6Thermal conductivity (average)Value listed in the manufacturer's online datasheetgrade VICTREX PEEK 450Gtest standard ISO 22007-4temperature 23 °Cdirection average (0.32 along flow)—
7Atomic oxygen erosionMass-loss erosion yield from the MISSE 2 flight samples, as compiled in the NASA report (the experiment is described in the report's references 11 and 12)experiment MISSE 2 PEACE polymers, exterior of the International Space Stationexposure 3.95 yr in low Earth orbit, 16 August 2001 to 30 July 2005fluence 8.43e21 atoms/cm2comparison Kapton H polyimide measured 3.00e-24 cm3/atom in the same tableDensity used for PEEK in the report is 1.2259 g/cm3 and ash fraction 8.26e-3 (Table II). The report says some stacked thin-film samples eroded through, so some listed yields are lower bounds; PEEK is listed without a greater-than sign.
8Total mass loss, 3D-printed PEEK (ECSS test)Thermal-vacuum outgassing test run by the paper's authors; the table value is the average of three samplesspecimen fused-filament-printed PEEK (APIUM filament, nozzle 410 °C)test standard ECSS-Q-ST-70-02Ctemperature 125 °C for 24 hvacuum below 1e-5 mbarcollector 25 °Csamples 3 (0.187, 0.186, 0.185)The same table quotes the NASA outgassing database for PEEK 450 pellets as TML 0.3%, CVCM 0.02%, RML 0.12% (second-hand; we did not open the database entry). The printed material's tensile test (ASTM D638, XY orientation) gave 78.0 +/- 7.2 MPa strength and 2.9 +/- 0.3 GPa modulus, below the datasheet figures (Table 7).
9Collected volatile condensable material, 3D-printed PEEK (ECSS test)Thermal-vacuum outgassing test run by the paper's authorsspecimen fused-filament-printed PEEK (APIUM filament, nozzle 410 °C)test standard ECSS-Q-ST-70-02Ctemperature 125 °C for 24 hvacuum below 1e-5 mbarcollector 25 °Csamples 3, each 0.01The limits listed in the paper are CVCM below 0.10% and recovered mass loss below 1.0%. The printed PEEK's recovered mass loss averaged 0.11%. Water vapour regained was not reported.
10Elongation at break retained after 46 months on the ISSTensile tests on flown samples compared with pristine film (the paper states 'about 15%')specimen extruded PEEK film 0.4 mm thick (FS-1100C, Sumitomo Bakelite), cut along the extrusion directionexposure 46 months (1403 days) on the ISS Russian Service Module, mean altitude 371 kminitial tensile load 0, 1.6 or 4.7 MPa (results similar after 46 months)test tensile, ASTM D882-95a, strain rate 0.1 /min, 23 °C and 50% relative humidityElastic modulus and yield strength were unchanged. Pristine yield strength was about 85 MPa and pristine elongation about 200%. The paper estimates the real atomic-oxygen fluence was only 2 to 3e20 atoms/cm2, far less than predicted, and that a silicon-oxide contamination layer may have shielded the samples. Ground tests point to ultraviolet crosslinking as the main cause of embrittlement.
11Ultimate tensile strength at 77 K—temperature 77 Kcrosshead speed 2 mm/minspecimen dumbbell cut from flat sheet by waterjet (ISO 37 Type I profile), PEEK grade not statedmean of repeats standard deviation 1.33 MPaUncertainty: standard deviation 1.33 MPaAt the same speed the mean was 99.55 MPa at room temperature (Table 1) and 114.57 MPa at 20 K (Table 3), where strain at break was only 2.70%. In the same room-temperature test PTFE gave 18.15 MPa and UHMWPE 31.99 MPa; at 77 K they gave 86.22 and 129.77 MPa. Modulus was 5.32 GPa at 77 K. This is a preprint version.
12Highest gamma dose in a tensile and nano-indentation studyRaman, X-ray diffraction, nano-indentation and tensile tests before and after irradiationsource of radiation cobalt-60 gamma irradiator, average dose rate 11.6 kGy/hrdoses 10 kGy, 100 kGy, 1 MGy and 5 MGytime at 5 MGy 17.9 daysspecimen 25 mm x 25 mm PEEK sample, grade and form not statedtensile test ambient 28 to 30 °C, 3 subsamples per doseA dose tested, not a tolerance limit. The abstract says mechanical characteristics stay relatively unchanged up to 5 MGy, but the body reports a distinct reduction in strain at failure after 100 kGy, a surprising decline in tensile strength, and modulus and hardness that rose up to 1 MGy then levelled off. The authors say sample numbers were too few for statistics. Raman showed no change.

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Atomic oxygen in low Earth orbit moderate Atomic oxygen eroded PEEK at about the same rate as Kapton H polyimide on the ISS.1
Space ultraviolet light and charged particles (ISS exterior) moderate Film turned brown and lost most of its stretch after 46 months, but kept its stiffness and yield strength.2
Concentrated sulphuric acid not rated The supplier lists concentrated sulphuric acid as the one incompatible material but gives no rate.3
Water, 23 degC and 100 degC low PEEK takes up only a little water, under 1% by mass even in boiling water.4
Corrosion details
#EnvironmentDetailsTest conditions
1 Atomic oxygen in low Earth orbit On the MISSE 2 flight PEEK had an erosion yield of 2.99e-24 cm3/atom, against 3.00e-24 for Kapton H in the same table. Fluoropolymers were far lower, for example FEP at 2.00e-25 and PTFE at 1.42e-25. On the ISS Russian Service Module, PEEK film lost only 9.2 micrometres of thickness in 46 months and the surface developed a cone-like pattern typical of atomic-oxygen attack. flight MISSE 2, 3.95 yr, fluence 8.43e21 atoms/cm2second flight MPAC&SEED, 0.4 mm film, 46 months, thickness loss 9.2 micrometres with no applied load
2 Space ultraviolet light and charged particles (ISS exterior) Flown PEEK film browned with exposure time and its elongation at break fell to about 15% of pristine after 46 months; elastic modulus and yield strength were unchanged. Ground tests found the electron beam hardly changed tensile properties and ultraviolet light caused the same trend, so the authors attribute the embrittlement mainly to ultraviolet-induced crosslinking. Samples were also covered by a silicon-oxide contamination layer. exposure 46 months (1403 days), ISS Russian Service Module, 371 km mean altitudefilm 0.4 mm FS-1100C
3 Concentrated sulphuric acid The Victrex safety data sheet gives concentrated sulphuric acid as the incompatible material and lists 'none known' for storage incompatibilities. It reports PEEK as insoluble in water and other solvents. It gives no corrosion rate or test, and we did not open a quantitative chemical-resistance table. basis supplier safety data sheet, covers PEEK granules including 450Grevision 20 May 2022
4 Water, 23 degC and 100 degC Saturation water absorption of PEEK 450G is 0.45% at 23 degC and 0.55% at 100 degC. grade VICTREX PEEK 450Gtest standard ISO 62state saturation

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

The supplier does not classify PEEK granules as hazardous, but toxicology data are mostly listed as unknown, and heated PEEK can burn skin badly.

The solid and its dust
The Victrex safety data sheet (20 May 2022) says the granules are not classified as dangerous and carry no hazard label. Dust gives mechanical irritation of the respiratory tract and may irritate the eyes, and many toxicology entries read 'Not known'.
Molten polymer
Molten PEEK sticks to skin and causes severe burns. The sheet advises cooling the area with water, not removing hardened product, and getting medical attention. Insulating gloves are advised when handling heated material.
Dust and fire
Dust is ignitable but does not sustain combustion, and the sheet warns that dust clouds can be explosive. It gives a minimum ignition spark energy above 5000 mJ and an auto-ignition point of 595 °C. Burning gives off oxides of carbon, and the polymer decomposes above 450 °C.

If it fails

These results are from flight exposure and laboratory tests on films and sheets, not from failures of finished spacecraft parts.

In orbit
PEEK film flown for 46 months on the ISS Russian Service Module kept its modulus and yield strength but retained only about 15% of its elongation at break, so it became brittle. Ground tests point to ultraviolet crosslinking as the main cause.
At hydrogen temperature
In tensile tests at 2 mm/min, strength rose to 198.14 MPa at 77 K but fell to 114.57 MPa at 20 K, and strain at break dropped from 8.09% to 2.70%.
Under gamma radiation
In a cobalt-60 study to 5 MGy, PEEK showed a distinct reduction in strain at failure after 100 kGy. The authors had expected little change and note that only three subsamples were tested per dose.

Handling and storage

Storage
Keep the granules enclosed in their original packing at room temperature. The supplier gives a storage life of more than 10 years and lists no incompatible material for storage.
Dust control
Avoid build-up of dust, use local exhaust ventilation and guard against static discharge. A fine-dust breathing mask is advised if exposure limits may be exceeded.
Chemicals
The sheet names concentrated sulphuric acid as the incompatible material. Purging a machine with another polymer at high temperature can also be hazardous.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Embrittlement in low Earth orbitmoderate severity46 months on the ISS Russian Service Module (ultraviolet, atomic oxygen, particles)Elongation at break fell to about 15% of pristine, while modulus and yield strength were unchanged, so a part that should stretch before breaking becomes brittle.
Strength loss at hydrogen temperaturemoderate severityCooling from 77 K to 20 KAt 2 mm/min ultimate tensile strength fell from 198.14 MPa at 77 K to 114.57 MPa at 20 K, and strain at break from 8.09% to 2.70%.
Loss of ductility under gamma radiationmoderate severityCobalt-60 gamma doses of 100 kGy and aboveA distinct reduction in strain at failure after 100 kGy, with the 5 MGy samples significantly less ductile than unirradiated ones, from three subsamples per dose.

Side effects on surrounding parts

Side effects on surrounding parts
AffectsEffect
Interpretation of the flight resultFlown film was covered with a pale silicon-and-oxygen contamination layer over about 70 to 80% of the exposed area; the authors suggest it shielded the samples from atomic oxygen and ultraviolet light, so the real exposure was much lower than predicted.
Appearance (a possible passive dose indicator, according to the authors)Gamma irradiation discoloured the PEEK samples in step with dose.

Handling and storage

  • Store enclosed in the original packing at room temperature; storage life more than 10 years. Avoid build-up of dust, use local exhaust ventilation, and take precautions against static discharge. Purging a machine with other polymers at high temperature can be hazardous.
  • Decomposes above 450 degC and gives off oxides of carbon in a fire. Do not use concentrated sulphuric acid with it.

Mitigations

  • Wear eye protection with side shields, insulating heat gloves when handling heated material, and a fine-dust breathing mask if exposure limits may be exceeded. The sheet lists general dust limits of 10 mg/m3 inhalable and 4 mg/m3 respirable.

Supply and geography

How common the raw materials are and where they come from.

PEEK polymer (resin)