Polyamide 6 (nylon 6) PA 6

(C6H11NO)n, repeat unit C6H11NO, molar mass 113.1590 per repeat unit

Polyamide 6 (nylon 6) is a semicrystalline polyamide made from caprolactam.

10 sources · Updated 2026-10-19 · CC BY 4.0

Evidence level

5 of 5

Flown or field-proven

Atomic oxygen

3.51×10^-24 cm³/atom

Heat

200 °C

Stiffness

3100 MPa

Recipe, share of the weight

  • C not statedCarbon
  • H not statedHydrogen
  • N not statedNitrogen
  • O not statedOxygen
  • C6H11NO not statedCaprolactam

Best for

Flight-proven polymer for atomic-oxygen exposure data in low Earth orbit (only one flight value read here)

Weakest at

Moisture uptake: the Aquafil sheet gives a saturation water uptake of 10 %, and the stiffness and strength values fall once conditioned

Risk at a glance

  • People None found. Partly verified
  • If it fails Moderate. Dimensional change and warpage from moisture
  • Corrosion Moderate. Moisture swells PA 6 anisotropically, and thickness changes more than length.

Quick facts: PA 6

Key properties of PA 6
PropertyValueBasis
Density1.12 to 1.15 g/cm³4 sourced values across conditions
Tensile strength70 to 76 MPa2 sourced values across conditions
Melting point220 to 221 °C3 sourced values across conditions

What is the density of Polyamide 6 (nylon 6) (PA 6)?

Polyamide 6 (nylon 6) (PA 6) has a density of 1.12 to 1.15 g/cm³. The range covers 4 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the melting point of Polyamide 6 (nylon 6) (PA 6)?

Polyamide 6 (nylon 6) (PA 6) has a melting point of 220 to 221 °C. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the tensile strength of Polyamide 6 (nylon 6) (PA 6)?

Polyamide 6 (nylon 6) (PA 6) has a tensile strength of 70 to 76 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is Polyamide 6 (nylon 6) (PA 6) used for?

Uses recorded in the sources include Gears and bearings; Load-bearing automotive and electronics parts; Fibres: parachutes, aircraft tyre cord and towing cables (wartime Germany).

Why it exists

Polyamide 6 is in this file because NASA flew it. The MISSE 2 PEACE polymer experiment put it on the outside of the ISS for 3.95 years, and it erodes at 3.51 x 10^-24 cm3/atom under the recorded atomic-oxygen fluence of 8.43e21 atoms/cm2. That is one flight value, not a qualification.

Where it's used

Gears and bearings

A PA 6 review says the polymer is frequently used for gears, bearings and engine covers because it resists mechanical stress.

Automotive and electronics

The same review says PA 6 is used for load-bearing structures in the automotive and electronics sectors because of its strength, stiffness and wear resistance.

Fibres and cords

Wikipedia says the first industrial nylon 6 went into parachutes, aircraft tyre cord and glider towing cables in wartime Germany.

3D printing

The PMC review says PA 6 is used in SLS and MJF additive manufacturing as glass-fibre composites, and that PA 6 processes are more cost-effective and resist dynamic loading. This is ground manufacturing, not a flight use.

Recipe

(C6H11NO)n, repeat unit C6H11NO, molar mass 113.1590 per repeat unit

Polyamide 6 is made by ring-opening polymerisation of caprolactam (C6H11NO). Unlike nylon 66, it is not a condensation polymer. When caprolactam is heated under nitrogen for about 4 to 5 hours (Wikipedia), the ring opens and the monomer joins the chain. The repeat unit, [-NH-(CH2)5-CO-]n, is C6H11NO (NASA Table IV; molar mass 113.1590 per repeat unit).

What PA 6 is made of
IngredientShare of the weightWhat it does
Carbon C not stated Backbone of the repeat unit (five CH2 groups and the carbonyl carbon).
Hydrogen H not stated Methylene and amide hydrogens of the repeat unit.
Nitrogen N not stated Amide nitrogen; hydrogen bonds between chains give the crystalline structure.
Oxygen O not stated Carbonyl oxygen of the amide group.
Caprolactam C6H11NO not stated Monomer. Ring-opening polymerisation makes it the repeat unit, so the monomer and repeat unit have the same formula.

Weight shares are as printed in the sources.

What it can do

Atomic oxygen

3.51×10^-24 cm³/atom

measured

In LEO flight it eroded at 3.51 x 10^-24 cm3/atom, measured in NASA MISSE 2 PEACE (Table I).

Heat

200 °C

measured

The Vinmar sheet gives a heat deflection temperature of 200 degC at 1.8 MPa and a melting point of 220 degC.

Stiffness

3100 MPa

measured

The Vinmar sheet gives 3100 MPa with no condition stated. The Aquafil sheet gives 2215 MPa after conditioning at 45 to 55 % RH.

How it compares

In the NASA flight set PA 6 and PA 66 are listed together. This profile reads only the PA 6 erosion row (3.51e-24 cm3/atom); the PA 66 value (1.80e-24) is not carried over. LANXESS says PA 6 absorbs water at almost twice the rate of PA 66. On the ground, the Ultramid B27 EX and Vinmar and Aquafil sheets give densities of 1.12 to 1.15 and 1.12 to 1.13 g/cm3 and melting points of 220 to 221 degC. The moisture numbers show the main weakness: 2.2 % water at 23 C/50 % rh and 8.5 % at saturation for B27 EX, with 10 % at saturation for the Aquafil and Durethan B 30 S values.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementPA 6PA 11PA 12PA 46PA 66PPA
Thermal behavior and safety
Melting temperature, ECONYL ECO 27 (DSC)221 °C5no datano datano datano datano data
Melting point, Vinmar PA6UFNATTypical value on the Vinmar datasheet, ISO 11357220 °Cno datano datano datano datano data
Heat deflection temperature at 1.8 MPa, Vinmar PA6UFNATISO 75; printed as 392 (200) F (C)200 °C12130 °Cno data190 °C75 °C260 °C
Melting point, Ultramid B27 EX220 °C18no datano datano datano datano data
Physical and electrical
Density, MISSE 2 reference value1.123 g/cm³21.04 g/cm³0.9 to 0.95 g/cm³1.18 g/cm³1.13 g/cc1.47 g/cm³
Density, Vinmar PA6UFNAT (specific gravity)1.12 (specific gravity, no unit printed)31.04 g/cm³0.9 to 0.95 g/cm³1.18 g/cm³1.13 g/cc1.47 g/cm³
Density, ECONYL ECO 271.13 g/cm³41.04 g/cm³0.9 to 0.95 g/cm³1.18 g/cm³1.13 g/cc1.47 g/cm³
Density, Ultramid B27 EX1.12 to 1.15 g/cm³171.04 g/cm³0.9 to 0.95 g/cm³1.18 g/cm³1.13 g/cc1.47 g/cm³
Other measurements
Atomic oxygen erosion yield, MISSE 2 PEACE flight3.51×10^-24 cm³/atom1no datano datano data1.8×10^-24 cm³/atomno data
Tensile modulus, Vinmar PA6UFNAT3100 MPa6no datano datano data3 GPano data
Tensile modulus, ECONYL ECO 27 (conditioned)2215 MPa7no datano datano data3 GPano data
Tensile strength, ECONYL ECO 27 (conditioned)70 MPa8no datano datano datano datano data
Tensile strength, Vinmar PA6UFNAT76 MPa9no datano datano datano datano data
Moisture absorption at saturation, ECONYL ECO 2710 %101.6 %0.52 %3.7 %2.8 %3.5 %
Moisture content as supplied, Vinmar PA6UFNAT0.2 % (maximum)11no datano datano datano datano data
Charpy notched impact at 23 degC, ECONYL ECO 278.1 kJ/m2137 kJ/m24.8 kJ/m2no datano datano data
Water absorption at 23 C / 50 % rh, Ultramid B27 EX2.2 %141.6 %0.52 %3.7 %2.8 %3.5 %
Water absorption at saturation in water, 23 C, Ultramid B27 EX8.5 %151.6 %0.52 %3.7 %2.8 %3.5 %
Equilibrium water content at 50 % rh, Durethan B 30 S (PA 6)3 %161.6 %0.52 %3.7 %2.8 %3.5 %
Water content on immersion in water, Durethan B 30 S (PA 6)Table 2 of LANXESS TI 2007-00310 %1.6 %0.52 %3.7 %2.8 %3.5 %
Moisture content as supplied, Ultramid B27 EX0.3 % (maximum)19no datano datano datano datano data

Why choose it, and why not

Good for

  • Atomic-oxygen flight data in LEO: the NASA value is measured in orbit.
  • Stiff, wear-resistant gears and bearings where humidity is controlled and dimensional change is allowed for (ground datasheets, PMC review).
  • Fibre and cord uses where moisture uptake is acceptable (Wikipedia).

Watch out for

  • Moisture: 2.2 % water at 23 C/50 % rh and 8.5 % at saturation for B27 EX; 10 % at saturation for the Aquafil and Durethan B 30 S values. These shift the mechanical values.
  • Dimensional change: 0.2 to 0.3 % length change per 1 % water absorbed, with a larger thickness change (LANXESS).
  • Hot water and steam conditioning cause oxidation discolouration and warping, and saturated steam is not recommended (LANXESS).
  • No UV, heat-ageing or hydrolysis data for PA 6 was read, so do not assume them from this profile.

PA 6 has one measured orbital erosion yield (MISSE 2) and sourced ground values for density, melting point and moisture. Its main limit is water: up to 10 % at saturation, with dimensional change of 0.2 to 0.3 % per 1 % water. The monomer is harmful and irritant, while the polymer hazard, UV and heat ageing are still not sourced.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Atomic oxygen erosion yield, MISSE 2 PEACE flightFlight exposure with mass loss over area and density; erosion yield as printed in NASA/TM-2008-215490 Table I. Not a dry or conditioned distinction: the sample was exposed in orbit.environment low Earth orbit, ISS, MISSE 2 PEACE tray 1 on the Quest airlock exterior, 2001-08-16 to 2005-07-30atomic oxygen fluence 8.43e21 atoms/cm2 (average of two Kapton H witness samples)equivalent sun hours 5,000 to 6,700 ESH, including 650 to 820 ESH Earth-reflectedduration 3.95 yrthermal cycling base-plate range nominally 40 to -30 °C—
2Density, MISSE 2 reference valueDensity reference value in NASA/TM-2008-215490 Table II (ref. 12)state as used for the flight yield calculation; not stated as dry or conditioned—
3Density, Vinmar PA6UFNAT (specific gravity)Typical value printed on the Vinmar resin datasheet (ISO 1183)state not stated by the supplier—
4Density, ECONYL ECO 27Typical value on the Aquafil ECONYL ECO 27 datasheet (ISO 1183); printed with range of variation plus or minus 0.020state not stated by the supplier for density; tolerance printed as 0.020 g/cm3—
5Melting temperature, ECONYL ECO 27 (DSC)DSC per ISO 11357-1; printed with range of variation plus or minus 2.5 degCheating rate 20 °C/min, 30 to 300 °Cstate not applicable (thermal, not moisture dependent as printed)—
6Tensile modulus, Vinmar PA6UFNATTypical value on the Vinmar datasheet, ISO 527-1 and -2; printed as 450,000 (3,100) psi (MPa)state not stated by the supplier; the datasheet prints no dry or conditioned splitrate not stated—
7Tensile modulus, ECONYL ECO 27 (conditioned)Typical value per ISO 527; printed with range of variation plus or minus 100 MPa. The datasheet footnote says dry-as-moulded values are shown before a slash where available; this row shows only the conditioned value.state conditioned: 24 h at RT, RH 45 to 55 %, as printed under the mechanical blocktest speed 1 mm/min—
8Tensile strength, ECONYL ECO 27 (conditioned)Typical value per ISO 527; printed with range of variation plus or minus 5 MPastate conditioned: 24 h at RT, RH 45 to 55 %test speed 50 mm/min—
9Tensile strength, Vinmar PA6UFNATTypical value per ISO 527; printed as 11,000 (76) psi (MPa)state not stated by the supplier—
10Moisture absorption at saturation, ECONYL ECO 27Typical value per ISO 62; printed with range of variation plus or minus 1.0 %state saturated in water at 23 °C—
11Moisture content as supplied, Vinmar PA6UFNATMaximum value printed on the Vinmar datasheet, ISO 15512state as supplied (maximum)—
12Heat deflection temperature at 1.8 MPa, Vinmar PA6UFNAT—load 1.8 MPaImplausible for an unfilled PA 6 at 1.8 MPa, far above PA 66 at the same load (70 to 75 degC). Treat as a probable datasheet or transcription error until checked against the Vinmar sheet; kept as printed, not used in the article comparisons.
13Charpy notched impact at 23 degC, ECONYL ECO 27ISO 179/1eA; printed with range of variation plus or minus 1.0 kJ/m2temperature 23 °C—
14Water absorption at 23 C / 50 % rh, Ultramid B27 EXTypical value printed on the BASF product informationstate standard atmosphere 23 C, 50 % rh; grade B27 EX (a PA 6 grade), not the plain B27 grade—
15Water absorption at saturation in water, 23 C, Ultramid B27 EXTypical value printed on the BASF product informationstate saturation in water at 23 C—
16Equilibrium water content at 50 % rh, Durethan B 30 S (PA 6)Table 2 of LANXESS TI 2007-003 (equilibrium water contents as % by weight)state equilibrium water content, printed as a maximum limit, 50 % relative humidity—
17Density, Ultramid B27 EXRange printed on the BASF product information (ISO 1183)state not stated as dry or conditioned—
18Melting point, Ultramid B27 EXTypical value printed on the BASF product information (ISO 3146)state typical value—
19Moisture content as supplied, Ultramid B27 EXMaximum value printed on the BASF product information (ISO 15512)state as supplied, pre-dried (maximum)—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Standard atmosphere 23 C, 50 % rh (service humidity) moderate Moisture swells PA 6 anisotropically, and thickness changes more than length.1
Standard atmosphere 23 C, 50 % rh, and later storage in room air low Water uptake and release are slow, and equilibrium can take much longer than a year.2
Hot water immersion at 80 to 90 C (conditioning route) moderate Fast conditioning, but the hot water causes oxidation discolouration and water stains.3
Saturated steam at 95 to 100 C and 100 % rh (conditioning route) moderate Saturated steam is not recommended: it causes water stains, oxidation and warping.4
Moisture uptake in service (mechanical effect) moderate Water acts as a plasticiser: stiffness and yield stress fall while ductility rises.5
Corrosion details
#EnvironmentDetailsTest conditions
1 Standard atmosphere 23 C, 50 % rh (service humidity) LANXESS reports an average length increase of 0.2 to 0.3 % per 1 % water absorbed for non-reinforced PA 6, a literature maximum volume increase of 0.9 % for non-reinforced PA 6 or PA 66, and a larger thickness increase than length increase. Strong moisture change can cause perceptible warpage. basis non-reinforced PA 6 moulded parts; the source notes that glass-fibre reinforcement cuts the length change below 0.1 % per 1 % waterreference LANXESS Section 2.3
2 Standard atmosphere 23 C, 50 % rh, and later storage in room air LANXESS says water absorption and release only take place very slowly at room temperature, so weather swings are often negligible. A part dried after absorbing 3 to 3.5 % water in the centre began to release water quickly in room air at 20 C and 50 to 60 % rh, but had still not reached equilibrium after a year. exposure molded parts; 10 mm thick part example in the source
3 Hot water immersion at 80 to 90 C (conditioning route) In the LANXESS overview of conditioning methods, immersion at 80 to 90 C is listed as rapid conditioning with the drawbacks of discolouration through oxidation and water stains. use a processing step to bring moulded parts to equilibrium, not service exposure
4 Saturated steam at 95 to 100 C and 100 % rh (conditioning route) LANXESS lists water stains, oxidation, deposit formation and a tendency to warp for saturated steam, and rates the method as not recommended. use a processing step, not service exposure
5 Moisture uptake in service (mechanical effect) Wikipedia states that nylon 6 is hygroscopic, absorbing up to 2.4 % of its weight in water, and that this greatly decreases the modulus and yield stress while increasing ductility. The Aquafil and Vinmar values in this file are not split by condition from one sheet, so check the condition before comparing. basis general statement, no test condition given in the source

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

All readers

The monomer caprolactam is harmful if swallowed, irritant, and harmful if inhaled (PubChem, 99.9 % of notifications). The polymer has no GHS classification in PubChem, and no polymer SDS was read.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Dimensional change and warpage from moisturemoderate severityParts that absorb water in service or during conditioning, with tight tolerancesLength change of 0.2 to 0.3 % per 1 % water absorbed, with a larger thickness change; perceptible warpage in extreme cases (LANXESS).
Loss of stiffness and yield strength when wetmoderate severityWater uptake (up to 10 % at saturation for the Durethan B 30 S immersion value and 2.4 % in the Wikipedia general statement)Modulus and yield stress fall while ductility rises. The conditioned Aquafil ECO 27 modulus is 2215 MPa against 3100 MPa for the Vinmar grade (different grades, condition not matched).
Oxidative discolouration and water stains during hot conditioning or dryinglow severityHot water immersion at 80 to 90 C, saturated steam, or granule drying above 75 to 80 CDiscolouration through oxidation and water stains; deposit formation with steam (LANXESS).
Atomic-oxygen erosion in low Earth orbitmoderate severityFlight exposure on the ISS outer surface (MISSE 2 PEACE, 3.95 years)Erosion yield 3.51e-24 cm3/atom at the recorded fluence of 8.43e21 atoms/cm2 (one flight measurement; NASA tabulates PA 66 at 1.80e-24).

Handling and storage

  • Dry PA 6 granules before moulding in a dehumidifying (desiccant) dryer with dew point of at least -20 to -25 C. LANXESS says a circulating-air oven below 100 C cannot fully dry PA granules and can add moisture. Keep drying at or below 75 to 80 C to avoid oxidative discolouration, except for heat-stabilised black grades. The permitted granule moisture for injection moulding is a maximum of 0.12 %.
  • Ultramid B27 EX is supplied pre-dried in moisture-proof containers. Store it protected from moisture, use it within 12 months, and use opened bags immediately.

Mitigations

  • Dry to the printed maximum moisture before moulding, then design for water-induced dimensional change of 0.2 to 0.3 % per 1 % water absorbed (LANXESS).

Supply and geography

How common the raw materials are and where they come from.

Caprolactam (monomer for nylon 6)

Polyamide 6 producers in Europe (capacity)