Aluminium alloy 5019 5019

Al-Mg alloy, AlMg5 / EN AW-5019: Mg 4.5 to 5.6, Mn 0.1 to 0.6, Cr max 0.2, Fe max 0.5, Si max 0.4, Zn max 0.2, Ti max 0.2, Cu max 0.1, other max 0.05 each and 0.15 total, Al remainder (wt%)

Also known as UNS A95019, EN 3.3555, EN name EN AW-5019, DIN AlMg5, BS N6, AA 5019

5019 (AlMg5, also written EN AW-5019, UNS A95019, AA 5019) is a wrought aluminium-magnesium alloy with about 4.5 to 5.6 % magnesium as its main alloying element.

    6 sources · Updated 2026-10-26 · CC BY 4.0

    Evidence level

    2 of 5

    Lab-measured

    Strength

    270 to 350 MPa tensile (H12)

    Weight

    2.64 g/cm3

    Heat

    110 to 140 W/(m·K)

    Sea and weather

    Very good (supplier rating)

    Recipe, share of the weight

    • Al not statedAluminium
    • Mg not statedMagnesium
    • Mn not statedManganese
    • Cr not statedChromium
    • Si not statedSilicon
    • Fe not statedIron
    • Zn not statedZinc
    • Ti not statedTitanium
    • Cu not statedCopper

    Best for

    Wrought rod, tube and wire where seawater and weathering resistance matter (supplier rates both very good)

    Weakest at

    Thin data: no yield strength was found for any tested temper, and the supplier rates hard brazing as poor

    Risk at a glance

    • People Low. Dust, fume and skin warnings
    • If it fails Moderate. Dust ignition during machining
    • Corrosion No data. No corrosion data recorded

    Quick facts: 5019

    Key properties of 5019
    PropertyValueBasis
    Density2.64 g/cm³1 sourced value
    Tensile strength250 to 385 MPa3 sourced values across conditions
    Young's modulus69 to 79 GPa2 sourced values across conditions
    Hardness (Brinell)65 to 95 HB1 sourced value
    Thermal conductivity110 to 140 W/(m·K)1 sourced value
    Melting point575 to 630 °C1 sourced value
    Specific heat904 J/(kg·K)1 sourced value
    Electrical resistivity0.053 to 0.067 Ω·mm²/m1 sourced value

    What is the density of Aluminium alloy 5019?

    Aluminium alloy 5019 has a density of 2.64 g/cm³. The source and test conditions are listed in the properties table on this page.

    What is the thermal conductivity of Aluminium alloy 5019?

    Aluminium alloy 5019 has a thermal conductivity of 110 to 140 W/(m·K). The source and test conditions are listed in the properties table on this page.

    What is the melting point of Aluminium alloy 5019?

    Aluminium alloy 5019 has a melting point of 575 to 630 °C. The source and test conditions are listed in the properties table on this page.

    What is the tensile strength of Aluminium alloy 5019?

    Aluminium alloy 5019 has a tensile strength of 250 to 385 MPa. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

    What is the Young's modulus of Aluminium alloy 5019?

    Aluminium alloy 5019 has a Young's modulus of 69 to 79 GPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

    What are the other names and codes for Aluminium alloy 5019?

    Aluminium alloy 5019 is also written as UNS A95019, EN 3.3555, EN name EN AW-5019, DIN AlMg5, BS N6, AA 5019. Each code is printed in the source listed beside it in the designations table.

    Why it exists

    5019 is a magnesium-rich aluminium alloy for wrought products. Supplier data give a density of 2.64 g/cm3, a tensile strength of 270 to 350 MPa in H12 rod, tube and wire, and 300 to 380 MPa in H24, with seawater and weathering resistance rated very good. The supplier also calls the alloy food safe. The sources read here name no aerospace or space application for this grade.

    Recipe

    Al-Mg alloy, AlMg5 / EN AW-5019: Mg 4.5 to 5.6, Mn 0.1 to 0.6, Cr max 0.2, Fe max 0.5, Si max 0.4, Zn max 0.2, Ti max 0.2, Cu max 0.1, other max 0.05 each and 0.15 total, Al remainder (wt%)

    5019 is a wrought aluminium-magnesium alloy, EN AW-5019 or AlMg5. Magnesium is the main alloying element at 4.5 to 5.6 wt%, with manganese, chromium, iron, silicon, zinc, titanium and copper as minor elements (Bikar listing, EN 573-3 limits). The sources read here do not describe how the product is made, and the composition below is the standard range, not a measured value.

    What 5019 is made of
    IngredientShare of the weightWhat it does
    Aluminium Al not stated The matrix of the alloy.
    Magnesium Mg not stated The main alloying element. The name AlMg5 refers to it.
    Manganese Mn not stated Minor alloying element.
    Chromium Cr not stated Minor element, limited by the standard.
    Silicon Si not stated Impurity or minor element, limited by the standard.
    Iron Fe not stated Impurity, limited by the standard.
    Zinc Zn not stated Minor element, limited by the standard.
    Titanium Ti not stated Minor element, limited by the standard.
    Copper Cu not stated Minor element, limited by the standard.

    Weight shares are as printed in the sources.

    What it can do

    Strength

    270 to 350 MPa tensile (H12)

    measured

    The H12 listing gives a tensile strength of 270 to 350 MPa for rod, tube and wire. The H24 listing gives 300 to 380 MPa.

    Weight

    2.64 g/cm3

    measured

    The supplier gives a density of 2.64 g/cm3.

    Heat

    110 to 140 W/(m·K)

    measured

    The H12 listing gives a thermal conductivity of 110 to 140 W/(m·K) at 20 °C.

    Sea and weather

    Very good (supplier rating)

    The H24 corrosion table rates seawater and weathering resistance very good. No test conditions are given.

    How it compares

    5019 is a magnesium-rich aluminium alloy with a density near 2.64 g/cm3 and a tensile strength of 250 to 385 MPa across the forms and tempers listed. The sources here give its density, stiffness and thermal figures only for this alloy, and they do not compare it with other grades numerically.

    The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

    Benchmarks
    Measurement501960617075-T6202450525XXX2195 (Al-Cu-Li)Al10502011201420172017A221923192618A30033103404750565083AlMg2AlMg36013606360826101AA7050AA8011Au-Al IMCsAl master alloys
    Thermal behavior and safety
    Melting range, EN AW-5019 H12 listing575 to 630 °C1no data532 °Cno data607.2 to 649 °Cno data1020 degF660 °C645 to 657 °C540 °C535 °C510 °C510 °C543 °C543 to 643 °C549 °C655 °C655 °C1068 to 1080 °F565 to 640 °C570 °C605 to 650 °C590 to 645 °C579 °C600 °C575 °C1090 °F490 °C640 to 655 °Cno data880 °C
    Thermal conductivity, EN AW-5019 H12 listingRange printed on a supplier product page110 to 140 W/(m·K)167 W/(m·K)130 W/m·K121 W/m-K138 W/m-K138 W/(m·K)no data220 W/(m·K)229 W/m.K140 W/m.K138 W/(m·K)140 W/m.K140 W/m.K130 W.m/m2.°Cno data147 W/m.K190 W/m.K160 W/m.Kno data109 to 117 W/(m·K)121 W/(m·K)138 W/(m·K)140 to 160 W/(m·K)164 W/(m·K)200 W/(m·K)180 W/(m·K)no data154 W/(m·K)210 to 220 W/(m·K)no datano data
    Specific heat capacity, EN AW-5019 H12 listingValue printed on a supplier product page904 J/(kg·K)no data960 J/kg·K0.875 J/g-°Cno datano datano data900 J/(kg·K)no datano datano data0.88 J/(g·°C)0.88 J/g-°C0.86 J/g.°Cno datano datano datano datano datano datano data898 J/(kg·K)900 J/(kg·K)no datano data896 J/(kg·K)no data0.86 J/g°Cno datano datano data
    Physical and electrical
    Density, 5019Value printed on a supplier product page2.64 g/cm³2.7 g/cm³2.8 Mg/m32.78 g/cc2.68 g/cc2.68 g/cm³0.096 lb/in32.7 g/cm³2.71 g/cm³2.82 g/cm³2.82 g/cm³2.79 g/cm³2.79 g/cm³2.84 g/cm³2.84 g/cm³2.76 g/cm³2.73 g/cm³2.73 g/cm³2.65 g/cm³2.64 g/cm³2.65 g/cm³2.69 g/cm³2.67 g/cm³2.71 g/cm³2700 kg/m32.7 g/cm³0.097 lb/cu.in2.83 g/cm³2.71 g/cm³no datano data
    Electrical resistivity, MSZ EN AW-50190.0526 to 0.0667 Ω·mm²/m34 µΩ·cm5.2 µΩ·cm5.82 µΩ·cmno data5.8 µΩ·cmno data2.646 µΩ·cmno datano data0.045 µΩ·mno datano data5.7 μΩ.cm²/cmno datano datano datano datano data5.88×10^-8 to 6.25×10^-8 Ω·m0.058 µΩ·m50 nΩ·mno datano data0.35 µΩ·m0.038 µΩ·mno datano data2.86×10^-8 to 2.94×10^-8 Ω·mno datano data
    Brinell hardness, MSZ EN AW-501965 to 95 HB6no datano datano datano datano datano datano data35 HB105 HBno data105 HB105 HBno datano data120 HBno data45 HBno datano datano datano datano datano datano datano datano datano datano datano datano data
    Other measurements
    Modulus of elasticity, EN AW-5019 H12 listingValue printed on a supplier product page70 GPa68.9 GPa71 GPa73.1 GPa70.3 GPa70.3 GPa11 MSI69 GPa69000 MPa70 GPa71 GPa72 GPa72 GPa73.8 x10^3 N/mm2no data71 GPa69.5 GPa69.5 GPano data71 GPa72 GPa70 GPa70 GPa71 GPa69.5 GPa70 GPano data71.5 GPa70 GPano datano data
    Modulus of elasticity, MSZ EN AW-501969 to 79 GPa268.9 GPa71 GPa73.1 GPa70.3 GPa70.3 GPa11 MSI69 GPa69000 MPa70 GPa71 GPa72 GPa72 GPa73.8 x10^3 N/mm2no data71 GPa69.5 GPa69.5 GPano data71 GPa72 GPa70 GPa70 GPa71 GPa69.5 GPa70 GPano data71.5 GPa70 GPano datano data
    Tensile strength, EN AW-5019 H12 rod, tube and wireRange printed on a supplier product page270 to 350 MPa310 MPa572 MPa469 MPa28 ksi228 MPa80 ksi88 MPa105 to 145 MPa300 MPa> 460 MPa427 MPa427 MPa> 62 ksi160 MPa420 MPa110 MPa> 140 MPa124 MPa300 MPa275 to 350 MPa190 to 230 MPa190 to 260 MPa410 MPa27 ksi> 300 MPa32000 psi> 483 MPa180 to 195 MPano datano data
    Tensile strength, EN AW-5019 H24 tube, rod and wireRange printed on a supplier product page300 to 380 MPa310 MPa572 MPa469 MPa28 ksi228 MPa80 ksi88 MPa105 to 145 MPa300 MPa> 460 MPa427 MPa427 MPa> 62 ksi160 MPa420 MPa110 MPa> 140 MPa124 MPa300 MPa275 to 350 MPa190 to 230 MPa190 to 260 MPa410 MPa27 ksi> 300 MPa32000 psi> 483 MPa180 to 195 MPano datano data
    Tensile strength, MSZ EN AW-5019250 to 385 MPa4310 MPa572 MPa469 MPa28 ksi228 MPa80 ksi88 MPa105 to 145 MPa300 MPa> 460 MPa427 MPa427 MPa> 62 ksi160 MPa420 MPa110 MPa> 140 MPa124 MPa300 MPa275 to 350 MPa190 to 230 MPa190 to 260 MPa410 MPa27 ksi> 300 MPa32000 psi> 483 MPa180 to 195 MPano datano data
    Elongation A, MSZ EN AW-5019 (minimum)> 2 %517 %11 %19 %25 %12 %8 %50 to 65 %4 to 8 %16 %> 6 %18 %18 %> 6 %12 %> 5 %25 %> 8 %12 %20 %> 12 %4 to 12 %> 12 %4 %8 %> 9 %> 8 %> 7 %> 1 %no datano data

    Why choose it, and why not

    Good for

    • Wrought rod, tube and wire where seawater and weathering resistance matter, with the supplier rating very good for both.
    • Parts that must be food safe, as the H24 supplier page states, with no further food-contact data read here.

    Watch out for

    • Brazing is rated poor by the supplier, so brazed joints may be weak.
    • No yield strength was found for any temper, so yield-based design values cannot be taken from these sources.
    • The corrosion rating is qualitative and has no test conditions behind it.
    • The hazard classes apply to the 5xxx family, not to 5019 alone.

    5019 is a corrosion-resistant Al-Mg wrought alloy by supplier rating, with a tensile range of about 270 to 380 MPa depending on temper. The sources here are thin on yield strength and on any space or flight use, and the hazard data are family-level.

    Technical details

    For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

    Other names and standards

    The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.

    Other names and standards
    SystemCodes
    UNSA95019
    EN3.3555
    EN nameEN AW-5019
    DINAlMg5
    BSN6
    AA5019

    Notes

    The method, full conditions and any caveat for the numbered rows above.

    Notes for the numbered rows
    #MeasurementMethodConditionsCaveat
    1Melting range, EN AW-5019 H12 listingRange printed on a supplier product page (melting range row)temper H12 (page listing)form not stated—
    2Modulus of elasticity, MSZ EN AW-5019Range printed in the physical properties section of a Total Materia pagetemperature not stated (band not tied to a value in the page)form not stated—
    3Electrical resistivity, MSZ EN AW-5019Range printed in the physical properties section of a Total Materia pagetemperature not stated (band not tied to a value in the page)form not stated—
    4Tensile strength, MSZ EN AW-5019Range printed in the mechanical properties section of a Total Materia pagetemperature 0 to 30 °Ctemper not statedform not stated—
    5Elongation A, MSZ EN AW-5019 (minimum)Minimum value printed in the mechanical properties section of a Total Materia pagetemperature 0 to 30 °Ctemper not statedgauge length A as printed (A5 or A50 not stated)—
    6Brinell hardness, MSZ EN AW-5019Range printed in the mechanical properties section of a Total Materia pagetemperature 0 to 30 °Ctemper not stated—

    Corrosion and compatibility

    What happens when it meets other materials and environments.

    Corrosion and compatibility
    EnvironmentConcernWhat happens
    Seawater and weathering (supplier rating, no test conditions) not rated The supplier rates seawater and weathering resistance of 5019 as very good.1
    Corrosion details
    #EnvironmentDetailsTest conditions
    1 Seawater and weathering (supplier rating, no test conditions) The corrosion properties table for the EN AW-5019 H24 listing rates seawater resistance very good and weathering resistance very good. No exposure time, test standard or corrosion rate is given. basis qualitative supplier rating printed as very good; the schema has no matching level, so rating is unknowntest none stated

    Risks and side effects

    Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

    For people

    The Hydro safety data sheet for the 5xxx series gives dust, fume, skin and environmental warnings. No health data for 5019 alone were found.

    Machining dust
    Metallic dust may ignite or explode, and dusts and fumes can cause metal fume fever (Hydro SDS, 5xxx series).
    Skin and inhalation
    The same sheet classifies the 5xxx product as a skin sensitiser (H317) and as suspected of causing cancer by inhalation (H351).
    Environment
    Small chips, fine turnings and processing dust may be toxic to aquatic life, according to the same sheet.

    If it fails

    The failure routes found in the sources are dust ignition, poor brazed joints and surface corrosion in service.

    Brazing
    The supplier rates hard brazing poor with and without flux, and soft brazing with flux poor. Friction soldering is rated acceptable.
    Corrosion
    The supplier rates seawater and weathering resistance very good. No test result for 5019 was found.

    Handling and storage

    Specify temper and form
    Strength ranges differ for H12 rod, tube and wire, H24 tube, rod and wire, and the 0 to 30 °C values, so state the temper and form before comparing figures.
    Dust control
    Keep machining chips and fines under control, and avoid breathing dust or fume, following the Hydro SDS.

    Test details
    The original wording and numbers from the sources, for readers who want them.

    Failure risks

    Failure risks
    FailureTrigger and consequence
    Dust ignition during machiningmoderate severityMachining, grinding or handling fine chips, turnings or dustThe Hydro sheet says metallic dusts may ignite or explode, and that dust, chips or ribbons can be ignited more easily by an ignition source or by improper machining.
    Poor brazed jointsmoderate severityHard brazing with or without flux, or soft brazing with fluxThe supplier rates hard brazing poor with and without flux, and soft brazing with flux poor. Friction soldering is rated acceptable.

    Handling and storage

    • Avoid breathing dust or fume, and keep chips, turnings and dust under control. The Hydro sheet gives the precautionary statement 'Avoid breathing dust, fume' and says processing dust may be toxic to aquatic life.
    • Specify the temper and product form before comparing strengths. The supplier listings give different tensile ranges for H12 rod, tube and wire (270 to 350 MPa) and for H24 tube, rod and wire (300 to 380 MPa), and Total Materia gives a 250 to 385 MPa range at 0 to 30 °C.

    Supply and geography

    How common the raw materials are and where they come from.

    Primary aluminium smelter production, 2025 estimate (world)

    Top producers (2025)
    China 60.8%, India 5.7%, Russia 5.3%, Canada 4.5%, United Arab Emirates 3.6%
    Recycling
    USGS: in 2025 about 3.6 million tons of aluminum were recovered from purchased scrap in the United States, about 56 % from new scrap and 44 % from old scrap. Old-scrap recovery was equivalent to about 28 % of apparent consumption.
    Substitutes
    USGS: composites can substitute for aluminum in aircraft fuselages and wings. Copper can replace aluminum in electrical and heat-exchange applications.