AISI 302 stainless steel (UNS S30200, EN 1.4310) 302

Fe balance, Cr 17.0 to 19.0 wt %, Ni 8.0 to 10.0 wt %, C max 0.15 wt %, Mn max 2.0 wt %, Si max 0.75 wt %, P max 0.045 wt %, S max 0.030 wt %, N max 0.10 wt % (Elgiloy nominal composition)

Also known as UNS S30200, EN 1.4310, EN name X10CrNi18-8, AISI 302, SAE 302, ASTM A313 · 4 more

AISI 302 (UNS S30200, EN 1.4310) is an austenitic chromium-nickel stainless steel with 17 to 19 % chromium and 8 to 10 % nickel, and up to 0.15 % carbon (Elgiloy nominal composition).

10 sources · Updated 2026-10-25 · CC BY 4.0

Evidence level

2 of 5

Lab-measured

Carry springs and wire

1300 to 2200 MPa spring temper tensile

Stay in shape when warm

16.6 µm/(m·°C)

Hold load in the annealed state

290 MPa typical yield

Survive short exposure to heat

925 °C continuous in air

Recipe, share of the weight

  • Fe not statedIron
  • Cr not statedChromium
  • Ni not statedNickel
  • C not statedCarbon
  • Mn not statedManganese
  • Si not statedSilicon
  • N not statedNitrogen

Best for

Springs, washers, screens and wire parts that need an 18-8 stainless steel with more carbon than 304 for strength, while keeping ductility (Elgiloy datasheet)

Weakest at

Strength in the annealed state (about 290 MPa typical yield), and ductility after heavy cold work (elongation falls from 48 % at 0 % cold work to 2.2 % at 80 % cold work, fwmetals table)

Risk at a glance

  • People Low. Not classified as hazardous in solid form
  • If it fails Moderate. Loss of ductility after heavy cold work
  • Corrosion Moderate. PREN value printed as 16.0 to 23.4 in the AGST datasheet.

Quick facts: 302

Key properties of 302
PropertyValueBasis
Density7.9 g/cm³2 sourced values across conditions
Yield strength195 to 338 MPa4 sourced values across conditions
Tensile strength500 to 2,200 MPa4 sourced values across conditions
Young's modulus193 to 200 GPa2 sourced values across conditions
Hardness (Brinell)230 HB1 sourced value
Thermal conductivity16.3 W/(m·K)1 sourced value
Thermal expansion (CTE)16.6 to 17.3 ppm/K2 sourced values across conditions
Melting point1,400 to 1,420 °C2 sourced values across conditions
Specific heat500 J/(kg·K)1 sourced value
Electrical resistivity7.2e-7 Ω·m2 sourced values across conditions
Maximum service temperature300 to 925 °C3 sourced values across conditions

What is the density of AISI 302 stainless steel?

AISI 302 stainless steel has a density of 7.9 g/cm³. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the thermal conductivity of AISI 302 stainless steel?

AISI 302 stainless steel has a thermal conductivity of 16.3 W/(m·K). The source and test conditions are listed in the properties table on this page.

What is the coefficient of thermal expansion of AISI 302 stainless steel?

AISI 302 stainless steel has a coefficient of thermal expansion of 16.6 to 17.3 ppm/K. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the melting point of AISI 302 stainless steel?

AISI 302 stainless steel has a melting point of 1,400 to 1,420 °C. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the yield strength of AISI 302 stainless steel?

AISI 302 stainless steel has a yield strength of 195 to 338 MPa. The range covers 4 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What are the other names and codes for AISI 302 stainless steel?

AISI 302 stainless steel is also written as UNS S30200, EN 1.4310, EN name X10CrNi18-8, AISI 302, SAE 302, ASTM A313. Each code is printed in the source listed beside it in the designations table.

What is AISI 302 stainless steel used for?

Uses recorded in the sources include Springs, washers, screens and cables; Building facades and architectural or structural parts in non-marine atmospheres; Food, beverage and dairy equipment, heat exchangers, piping and process tanks.

Why it exists

AISI 302 is a higher-carbon version of 304 that keeps good ductility while gaining strength in cold-worked and spring tempers. Its datasheets give a density of 7.90 g/cm3, an elastic modulus of 200 GPa (Elgiloy) or 193 GPa (AZoM), and a mean thermal expansion of 16.6 µm/(m·°C) from 20 to 100 °C. Those figures are the reason the grade is chosen for springs and wire.

Where it's used

Springs, washers and wire forms

AZoM says the grade is widely used in stamping, spinning and wire forming, and is used for springs, washers, screens and cables.

Architectural and structural parts

The RoyMech page lists building facades and architectural or structural uses in non-marine atmospheres.

Food and process equipment

The RoyMech page lists food, beverage and dairy equipment, heat exchangers, piping and process tanks.

Recipe

Fe balance, Cr 17.0 to 19.0 wt %, Ni 8.0 to 10.0 wt %, C max 0.15 wt %, Mn max 2.0 wt %, Si max 0.75 wt %, P max 0.045 wt %, S max 0.030 wt %, N max 0.10 wt % (Elgiloy nominal composition)

AISI 302 is an iron-based alloy of chromium and nickel with about 0.15 % carbon, the 18-8 type austenitic family. The composition ranges are the nominal ASTM limits printed in the Elgiloy datasheet, in weight percent. The Elgiloy datasheet notes that 304, which has lower carbon, has largely replaced 302 in use.

What 302 is made of
IngredientShare of the weightWhat it does
Iron Fe not stated The matrix of the alloy; the other elements are dissolved in it.
Chromium Cr not stated Gives the stainless steel its corrosion and oxidation resistance.
Nickel Ni not stated Keeps the structure austenitic and non-magnetic in the annealed state.
Carbon C not stated Higher than in 304; it raises strength and makes 302 useful for temper-rolled spring products (Elgiloy datasheet).
Manganese Mn not stated Minor element, listed as a maximum in the Elgiloy composition table.
Silicon Si not stated Minor element, listed as a maximum in the Elgiloy composition table; AZoM and fwmetals print 1.00 %.
Nitrogen N not stated Minor element, listed as a maximum in the Elgiloy composition table.

Weight shares are as printed in the sources.

What it can do

Carry springs and wire

1300 to 2200 MPa spring temper tensile

measured

Alloy Wire International gives an approximate tensile strength of 1300 to 2200 N/mm2 for spring temper.

Stay in shape when warm

16.6 µm/(m·°C)

measured

The mean coefficient of linear thermal expansion is 16.6 µm/(m·°C) from 20 to 100 °C (Elgiloy datasheet).

Hold load in the annealed state

290 MPa typical yield

measured

The Elgiloy datasheet gives 290 MPa as the typical 0.2 % yield strength of the annealed grade, and the EN ISO 6931-1 minimum for solution-annealed 1.4310 is 195 MPa.

Survive short exposure to heat

925 °C continuous in air

measured

The RoyMech page gives 925 °C for continuous service in air and 870 °C for intermittent service. The AGST page gives up to 300 °C; the two conflict.

How it compares

The datasheets for AISI 302 agree broadly on density (7.90 g/cm3 from Elgiloy, 7.9 kg/dm3 from AGST) and on the 193 to 200 GPa modulus range. They differ on annealed strength (290 MPa Elgiloy typical yield, 275 MPa AZoM strip, 195 MPa EN minimum) and on the maximum service temperature (925 °C continuous in RoyMech, up to 300 °C in the AGST page). The values are for the grade as printed in each source and should be read as examples of spread, not a ranking.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
Measurement302304 (UNS S30400)301 (UNS S30100)303 (UNS S30300)316 (UNS S31600)316L (UNS S31603)304L (UNS S30403)309310S (UNS S31008, EN 1.4845)317L321347347H904L (UNS N08904, EN 1.4539)Nitronic 60
Thermal behavior and safety
Melting point, 302 (Alloy Wire International)1420 °C31673 K1399 to 1421 °C1455 °C1390 °C1390 °C1399 to 1421 °C2550 to 2650 °F1410 °C1390 to 1440 °C1398 to 1446 °C1398 to 1446 °C2550 to 2635 degF1300 to 1390 °Cno data
Melting point, 302 (RoyMech)1400 °C41673 K1399 to 1421 °C1455 °C1390 °C1390 °C1399 to 1421 °C2550 to 2650 °F1410 °C1390 to 1440 °C1398 to 1446 °C1398 to 1446 °C2550 to 2635 degF1300 to 1390 °Cno data
Thermal conductivity, 302 at 100 °C (Elgiloy datasheet)16.2 W/(m·K)1014 W/m.K16.3 W/m.K15 W/m°C14.6 W/m.K14.6 W/m·K16.3 W/m·K15.6 W/m·K13 W/(m·K)14 W/(m·K)16.3 W/(m·K)16.3 W/(m·K)14 W/m.°C12 W/(m·K)9 Btu/ft hr °F
Thermal conductivity, 302 at 22 °C (fwmetals datasheet)16.3 W/(m·°C)1114 W/m.K16.3 W/m.K15 W/m°C14.6 W/m.K14.6 W/m·K16.3 W/m·K15.6 W/m·K13 W/(m·K)14 W/(m·K)16.3 W/(m·K)16.3 W/(m·K)14 W/m.°C12 W/(m·K)9 Btu/ft hr °F
Specific heat capacity, 1.4310 at 20 °C (HSM Stahl)500 J/kg K12490 J/kg.K500 J/kg.K500 J/kg°C450 J/kg.K450 J/kg °K500 J/kg·K502 J/kg·K480 J/(kg·K)500 J/(kg·K)500 J/kg K500 J/(kg·K)485 J/(kg.°C)450 J/(kg·K)0.12 Btu/lb °F
Physical and electrical
Density, 302 at 20 °C (Elgiloy datasheet)7.9 g/cm³17.85 Mg/m38.03 g/cm³7.9 kg/dm38.027 g/cm³8.03 g/cm³7.9 g/cm³8.03 g/cm³7.8 kg/dm38.027 g/cm³7.92 g/cm³7.96 g/cm³7.98 kg/dm37.95 g/cm³7.622 gm/cm³
Density, 1.4310 at 20 °C (AGST datasheet)7.9 kg/dm327.85 Mg/m38.03 g/cm³7.9 kg/dm38.027 g/cm³8.03 g/cm³7.9 g/cm³8.03 g/cm³7.8 kg/dm38.027 g/cm³7.92 g/cm³7.96 g/cm³7.98 kg/dm37.95 g/cm³7.622 gm/cm³
Electrical resistivity, 302 at 20 °C (Elgiloy datasheet)72 µΩ·cm1365 10-8 ohm.m72 µΩ·cm72 microhm-cm69 10-8 ohm.m74 μΩ·cm72 microhm-cm78 µΩ·cm0.86 Ω·mm²/m475 Ohm-circ mil/ft72 microhm·cm72 µΩ·cmno data95.2 µΩ·cm98.2 microhm-cm
Electrical resistance per length, 1.4310 at room temperature (HSM Stahl)0.73 Ω·mm²/m1465 10-8 ohm.m72 µΩ·cm72 microhm-cm69 10-8 ohm.m74 μΩ·cm72 microhm-cm78 µΩ·cm0.86 Ω·mm²/m475 Ohm-circ mil/ft72 microhm·cm72 µΩ·cmno data95.2 µΩ·cm98.2 microhm-cm
Hardness, Brinell maximum, solution annealed (EN ISO 6931-1)< 230 HB25no datano datano datano datano data< 201 HBno datano data< 217 HB< 217 HBno datano datano datano data
Other measurements
Modulus of elasticity in tension, 302 at 20 °C (Elgiloy datasheet)200 GPa5200 GPa193 GPa193 GPa200 GPa193 GPa200 GPa200 GPa195 GPa200 GPa193 GPa193 GPa200 GPa195 GPa180 GPa
Elastic modulus, annealed strip (AZoM)193 GPa6200 GPa193 GPa193 GPa200 GPa193 GPa200 GPa200 GPa195 GPa200 GPa193 GPa193 GPa200 GPa195 GPa180 GPa
Poisson's ratio, annealed strip (AZoM)0.27 to 0.3 -70.27 dimensionlessno datano data0.265 dimensionlessno datano datano datano data0.3 -no datano datano datano data0.298 -
Mean coefficient of linear thermal expansion, 20 to 100 °C (Elgiloy datasheet)16.6 µm/(m·°C)8no data16.6 10-6/K16 10-6/°C16.5 10-6/K16.5 10-6 cm/cm/°C16.6 10-6 cm/cm/°C15.6 µm/(m·K)16.5 ppm/K16.5 10^-6 cm/cm/°C16.6 ppm/K16.6 ppm/K9.2 in/in.degF x 10^-615.8 ppm/K15.8 µm/m/°C
Coefficient of linear thermal expansion, 0 to 100 °C (RoyMech)Value printed in a reference property table17.3 ppm/K9no data16.6 10-6/K16 10-6/°C16.5 10-6/K16.5 10-6 cm/cm/°C16.6 10-6 cm/cm/°C15.6 µm/(m·K)16.5 ppm/K16.5 10^-6 cm/cm/°C16.6 ppm/K16.6 ppm/K9.2 in/in.degF x 10^-615.8 ppm/K15.8 µm/m/°C
Yield strength, 0.2 % offset, annealed, typical (Elgiloy datasheet)290 MPa15> 205 MPa205 MPa> 172 MPa205 MPa170 MPa> 170 MPa290 MPa290 MPa> 205 MPa> 205 MPa> 205 MPa> 30 ksi> 240 MPa> 345 MPa
Yield strength, 0.200 % strain, annealed strip (AZoM)275 MPa16> 205 MPa205 MPa> 172 MPa205 MPa170 MPa> 170 MPa290 MPa290 MPa> 205 MPa> 205 MPa> 205 MPa> 30 ksi> 240 MPa> 345 MPa
Yield strength, Rp0.2, solution annealed, minimum, diameter up to 40 mm (EN ISO 6931-1)> 195 MPa17> 205 MPa205 MPa> 172 MPa205 MPa170 MPa> 170 MPa290 MPa290 MPa> 205 MPa> 205 MPa> 205 MPa> 30 ksi> 240 MPa> 345 MPa
Yield strength, 0 % cold worked wire, typical (fwmetals datasheet)338 MPa18> 205 MPa205 MPa> 172 MPa205 MPa170 MPa> 170 MPa290 MPa290 MPa> 205 MPa> 205 MPa> 205 MPa> 30 ksi> 240 MPa> 345 MPa
Tensile strength, annealed, typical (Elgiloy datasheet)655 MPa19> 515 MPa515 MPa> 517 MPa515 MPa485 MPa> 485 MPa621 MPa610 MPa> 515 MPa> 515 MPa> 515 MPa> 75 ksi530 to 730 MPa> 655 MPa
Tensile strength, annealed strip (AZoM)620 MPa20> 515 MPa515 MPa> 517 MPa515 MPa485 MPa> 485 MPa621 MPa610 MPa> 515 MPa> 515 MPa> 515 MPa> 75 ksi530 to 730 MPa> 655 MPa
Tensile strength, solution annealed, diameter up to 40 mm (EN ISO 6931-1)500 to 700 MPa21> 515 MPa515 MPa> 517 MPa515 MPa485 MPa> 485 MPa621 MPa610 MPa> 515 MPa> 515 MPa> 515 MPa> 75 ksi530 to 730 MPa> 655 MPa
Tensile strength, spring temper, approximate (Alloy Wire International)1300 to 2200 MPa22> 515 MPa515 MPa> 517 MPa515 MPa485 MPa> 485 MPa621 MPa610 MPa> 515 MPa> 515 MPa> 515 MPa> 75 ksi530 to 730 MPa> 655 MPa
Elongation in 2 in, annealed, typical (Elgiloy datasheet)55 %23> 40 %40 %> 35 %40 %40 %> 40 %49 %42 %> 40 %> 35 %> 40 %> 40 %> 35 %> 35 %
Elongation at break, longitudinal, minimum, diameter up to 40 mm (EN ISO 6931-1)> 40 %24> 40 %40 %> 35 %40 %40 %> 40 %49 %42 %> 40 %> 35 %> 40 %> 40 %> 35 %> 35 %
Maximum service temperature, continuous, in air (RoyMech)Value printed in a reference property table925 °C26no data840 °Cno data1023 Kno data< 426 °C2000 °F1050 °Cno data850 °C800 °C850 °C< 400 °Cno data
Maximum service temperature, intermittent, in air (RoyMech)Value printed in a reference property table870 °Cno data840 °Cno data1023 Kno data< 426 °C2000 °F1050 °Cno data850 °C800 °C850 °C< 400 °Cno data
Maximum use temperature (AGST datasheet)300 °C27no data840 °Cno data1023 Kno data< 426 °C2000 °F1050 °Cno data850 °C800 °C850 °C< 400 °Cno data
Approximate operating temperature, lower limit, annealed (Alloy Wire International)-200 °C28no datano datano datano datano datano datano datano datano datano datano datano datano datano data

Why choose it, and why not

Good for

  • Springs, washers, screens and cables in an 18-8 austenitic steel with more carbon than 304 (AZoM, RoyMech).
  • Continuous service in air is listed up to 925 °C by RoyMech; AGST gives up to 300 °C.
  • Non-magnetic annealed stainless steel with a 200 GPa modulus (Elgiloy datasheet).

Watch out for

  • Heavy cold work lowers ductility sharply (fwmetals table) and makes the steel magnetic (AZoM).
  • Welded and forged parts need annealing to keep full corrosion resistance (AZoM).
  • The datasheets disagree on the maximum service temperature, on silicon, and on the EN and ASTM composition ranges.
  • No space-environment data (outgassing, atomic oxygen, radiation) was found for this grade in the sources read.

AISI 302 is a higher-carbon 18-8 austenitic stainless steel for springs, washers and wire, with a density of 7.90 g/cm3, a modulus of 200 GPa in the Elgiloy datasheet, and a typical annealed yield of 290 MPa. It is harder to weld than 304 and loses ductility under heavy cold work. Its service-temperature figures conflict between sources, and this profile has no sourced space-environment data.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Other names and standards

The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.

Other names and standards
SystemCodes
UNSS30200
EN1.4310
EN nameX10CrNi18-8
AISI302
SAE302
ASTMA313, A580
AMS5688
Trade nameV2A, Alloy 302

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Density, 302 at 20 °C (Elgiloy datasheet)Value printed in a supplier datasheet, Physical Properties table, At 20 °C columngrade 302temperature 20 °Cunit in source 0.285 lb./in3 at 70 °F—
2Density, 1.4310 at 20 °C (AGST datasheet)Value printed in a distributor datasheet, Physical properties table, and repeated in the intro textgrade 1.4310 / AISI 302temperature 20 °Cunit in source 7,9 kg/dm³—
3Melting point, 302 (Alloy Wire International)Value printed in a manufacturer alloy details tablegrade 302unit in source 2590 °F—
4Melting point, 302 (RoyMech)Value printed in a reference property table; the page prints no test conditiongrade 302temperature not printedunit in source 2552 °F (printed value has a formatting error in the imperial column)The RoyMech page gives 1400 °C; the Alloy Wire page gives 1420 °C. Both are kept because the sources do not state the same basis.
5Modulus of elasticity in tension, 302 at 20 °C (Elgiloy datasheet)Value printed in a supplier datasheet, Physical Properties tablegrade 302temperature 20 °Cunit in source 200 x 10^3 MPa in tension—
6Elastic modulus, annealed strip (AZoM)Value printed in a reference property table for annealed stripform annealed stripunit in source 193 GPa (28000 ksi)The Elgiloy datasheet gives 200 GPa and AZoM gives 193 GPa, so the two values are kept separately.
7Poisson's ratio, annealed strip (AZoM)Range printed in a reference property table for annealed stripform annealed stripunit in source 0.27-0.30—
8Mean coefficient of linear thermal expansion, 20 to 100 °C (Elgiloy datasheet)Value printed in a supplier datasheet, Physical Properties tablegrade 302temperature 20 to 100 °Cunit in source 16.6 μm/m-oC (20-100oC)—
9Coefficient of linear thermal expansion, 0 to 100 °C (RoyMech)—grade 302temperature 0 to 100 °Cunit in source 17.3 x 10-6 °C-1The Elgiloy datasheet gives 16.6 µm/(m·°C) from 20 to 100 °C, so the two temperature bases differ slightly.
10Thermal conductivity, 302 at 100 °C (Elgiloy datasheet)Value printed in a supplier datasheet, Physical Properties tablegrade 302temperature 100 °Cunit in source 16.2 W/m-K (100oC)—
11Thermal conductivity, 302 at 22 °C (fwmetals datasheet)Value printed in a supplier datasheet, Physical properties table, footnoted as calculated at 22 °Cgrade 302 (ASTM A313)temperature 22 °Cunit in source 113 BTU·in/(hr·ft²·°F)—
12Specific heat capacity, 1.4310 at 20 °C (HSM Stahl)Value printed in a distributor datasheet, Physical properties at 20 °C blockgrade 1.4310temperature 20 °Cunit in source J/kg K—
13Electrical resistivity, 302 at 20 °C (Elgiloy datasheet)Value printed in a supplier datasheet, Physical Properties table, At 20oC columngrade 302temperature 20 °Cunit in source 72 μ ohm.cm—
14Electrical resistance per length, 1.4310 at room temperature (HSM Stahl)Value printed in a distributor datasheet, Physical properties tablegrade 1.4310temperature room temperatureunit in source 0,73 (ohm) mm²/mThe same value appears on the AGST page as electronic resistance at room temperature in Ω mm²/m. It equals 73 µΩ·cm, close to the 72 µΩ·cm in the Elgiloy datasheet.
15Yield strength, 0.2 % offset, annealed, typical (Elgiloy datasheet)Typical value printed in a supplier datasheet, Typical Room Temperature Mechanical Properties tabletemper annealedbasis typical, based on ASTM A240 per the datasheet noteunit in source 42 ksi (290 MPa)Typical, not a minimum. A specification minimum for solution-annealed 1.4310 is recorded separately.
16Yield strength, 0.200 % strain, annealed strip (AZoM)Value printed in a reference property table for annealed stripform annealed stripmeasure 0.200 % strainunit in source 275 MPa (39900 psi)The Elgiloy typical annealed value is 290 MPa. The two are different sources and forms and are not averaged.
17Yield strength, Rp0.2, solution annealed, minimum, diameter up to 40 mm (EN ISO 6931-1)Minimum value printed in a distributor datasheet, Mechanical properties tablegrade 1.4310temper solution annealeddiameter up to 40 mmbasis minimum, EN ISO 6931-1unit in source ≥ 195 N/mm2—
18Yield strength, 0 % cold worked wire, typical (fwmetals datasheet)Typical value printed in a supplier datasheet, Mechanical properties table, first rowform wirecold work 0 %basis typical, values may not represent all diametersunit in source 338 MPa [49 ksi]Cold-worked rows in the same table rise to 1165 MPa at 37 % cold work; only the 0 % row is entered here.
19Tensile strength, annealed, typical (Elgiloy datasheet)Typical value printed in a supplier datasheet, Typical Room Temperature Mechanical Properties tabletemper annealedbasis typical, based on ASTM A240 per the datasheet noteunit in source 95 ksi (655 MPa)—
20Tensile strength, annealed strip (AZoM)Value printed in a reference property table for annealed stripform annealed stripunit in source 620 MPa (89900 psi)Differs from the 655 MPa typical in the Elgiloy datasheet; the two are for different forms.
21Tensile strength, solution annealed, diameter up to 40 mm (EN ISO 6931-1)Range printed in a distributor datasheet, Mechanical properties tablegrade 1.4310temper solution annealeddiameter up to 40 mmunit in source 500-700 N/mm2The AGST PDF of the same sheet prints 500-750 N/mm2 for the same condition; the webpage figure of 500-700 is used here.
22Tensile strength, spring temper, approximate (Alloy Wire International)Range printed in a manufacturer properties table for spring tempertemper spring temperbasis approximate, as suppliedunit in source 1300 – 2200 N/mm²—
23Elongation in 2 in, annealed, typical (Elgiloy datasheet)Typical value printed in a supplier datasheet, Typical Room Temperature Mechanical Properties tabletemper annealedgauge length 2 in (50.8 mm)basis typical—
24Elongation at break, longitudinal, minimum, diameter up to 40 mm (EN ISO 6931-1)Minimum value printed in a distributor datasheet, Mechanical properties tablegrade 1.4310temper solution annealeddiameter up to 40 mmunit in source 40 %—
25Hardness, Brinell maximum, solution annealed (EN ISO 6931-1)Maximum value printed in a distributor datasheet, Mechanical properties tablegrade 1.4310temper solution annealeddiameter up to 40 mmhardness_brinell is not a canonical name in spores/property-canon.yaml; see gaps.
26Maximum service temperature, continuous, in air (RoyMech)—exposure continuous, in airunit in source 925 °C (1697 °F)The AGST page gives "up to 300 °C" as the maximum use temperature. The two figures conflict and both are kept.
27Maximum use temperature (AGST datasheet)Maximum value printed in a distributor datasheet introductiongrade 1.4310unit in source up to 300 °CConflicts with the 925 °C continuous figure from RoyMech. The basis of the AGST figure is not stated on the page.
28Approximate operating temperature, lower limit, annealed (Alloy Wire International)Approximate range printed in a manufacturer properties table; the upper limit of 300 °C is the same figure as the AGST datasheetcondition annealed or spring temperunit in source -200 to +300 °C (-330 to +570 °F)—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Wide range of moderately oxidising to moderately reducing environments low Useful corrosion resistance in a wide range of moderately oxidising to moderately reducing environments.1
General corrosion and fabricability low Excellent combination of corrosion resistance and fabricability (Elgiloy).2
Pitting resistance, PREN moderate PREN value printed as 16.0 to 23.4 in the AGST datasheet.3
Welded and forged parts, intergranular attack moderate Post-weld annealing dissolves chromium carbide to improve intergranular resistance.4
Corrosion details
#EnvironmentDetailsTest conditions
1 Wide range of moderately oxidising to moderately reducing environments The RoyMech page says the alloy "provides useful resistance to corrosion on a wide range of moderately oxidising to moderately reducing environments" and that its corrosion resistance is comparable to 304. No test result or rate is given. basis qualitative statement, no test result or rate given
2 General corrosion and fabricability The Elgiloy datasheet says the alloy "represents an excellent combination of corrosion resistance and fabricability". The datasheet notes that 304 has largely replaced 302 because lower carbon is now easily reached with AOD melting. basis qualitative statement, no test result or rate given
3 Pitting resistance, PREN The AGST page prints a PREN value of 16.0 to 23.4 in its introduction and corrosion section. The page gives no test method or environment for the value. basis PREN value as printed, no test condition given
4 Welded and forged parts, intergranular attack The AZoM page says post-weld annealing dissolves chromium carbide "so as to provide maximum resistance to inter-granular attack", and that forgings "should be fully annealed after all operations so as to maintain full corrosion resistance". basis qualitative statement from processing guidance, no test result

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

The only hazard statement in the sources is the North American Stainless SDS for stainless steel of all grades. It classes the solid alloy as an article and not hazardous in solid form.

Solid alloy
The NAS SDS says stainless steel is considered an article and not hazardous in its solid form. The SDS does not name AISI 302.
Processing
The same SDS says cutting, milling, grinding, melting and welding can emit hazardous materials, and lists carcinogenicity Category 1B for the emitted elements.

If it fails

The failure routes in these sources are qualitative or tied to processing: heavy cold work, cold forming and missed annealing.

Cold work
The fwmetals table shows elongation falling from 48 % at 0 % cold work to 2.2 % at 80 % cold work.
Magnetism
The AZoM page says cold working makes the alloy magnetic, so annealing restores a non-magnetic condition.

Handling and storage

Heat treatment
Solution anneal at 1000 to 1100 °C with air or water cooling, and stress relief at 250 °C for 1 hour.
Welding
AZoM recommends resistance or shielded fusion welding with filler AWS E/ER308 or 312.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Loss of ductility after heavy cold workmoderate severityHeavy cold drawing or rolling of the alloyThe fwmetals table gives elongation of 48 % at 0 % cold worked, 9.8 % at 20 %, 2.2 % at 80 % and 2.2 % at 90 % cold worked. Heavy cold work leaves little ductility for further forming.
Loss of non-magnetic condition after cold worklow severityCold forming or cold workingThe AZoM page says cold working causes the alloy to gain magnetic properties, so post-fabrication annealing is needed to restore a non-magnetic condition.
Intergranular attack after welding or forging without annealingmoderate severityWelded or forged parts not annealed after processingThe AZoM page says forgings should be fully annealed after all operations to maintain full corrosion resistance, and that post-weld annealing improves resistance to intergranular attack.

Handling and storage

  • Solution anneal at 1000 to 1100 °C, cooling in air or water (AGST datasheet). Hot forming 1200 to 900 °C, cooling in air.
  • Stress relieve at 250 °C for 1 hour, cooled in air, for annealed or spring-temper parts (Alloy Wire International).
  • AZoM recommends resistance or shielded fusion welding methods, with filler AWS E/ER308 or 312.
  • Grade 302 requires slow speeds and high feeds to overcome its tendency to work harden (AZoM).

Mitigations

  • Anneal after forming to restore a non-magnetic condition (AZoM).

Supply and geography

How common the raw materials are and where they come from.

Nickel (mine production, 8 to 10 wt % of the grade)

Top producers (2025)
Indonesia 66.7%, Philippines 6.9%, Russia 5.1%, New Caledonia 3.6%
Recycling
USGS: nickel recovered from scrap accounted for approximately 60 % of apparent consumption in 2025.
Substitutes
USGS: low-nickel, duplex or ultrahigh-chromium stainless steels have been substituted for austenitic grades in construction.

Chromium (mine production, 17 to 19 wt % of the grade)

Top producers (2025)
South Africa 45.1%, Turkey 17.6%, Kazakhstan 13.7%, India 5.9%
Recycling
USGS: recycled chromium, contained in reported stainless-steel scrap receipts, accounted for 21 % of apparent consumption in 2025.
Substitutes
USGS: chromium has no substitute in stainless steel, the leading end use.