Antimonial lead Pb-Sb

Pb-Sb alloy: lead with 1 to 12 wt% antimony

Antimonial lead is lead alloyed with antimony, in this profile's scope 1 to 12 wt% Sb.

12 sources · Updated 2026-10-26 · CC BY 4.0

Evidence level

2 of 5

Lab-measured

Strength and stiffness

34.8 to 38.9 MPa

Stopping photons

5.549 cm2/g for lead at 100 keV

Density of the element

6.68 g/cm3 (antimony)

Recipe, share of the weight

  • Pb not statedLead
  • Sb not statedAntimony

Best for

Lead-acid battery grids that need strength and good castability from a small antimony addition, and a recycling chain that already exists (USGS: secondary antimony comes from spent lead-acid batteries)

Weakest at

Antimony leaches out of the positive grid, which raises gassing, water loss and self-discharge; lead is a reproductive toxicant with no known safe blood lead level (WHO), which limits handling and disposal

Risk at a glance

  • People Severe. Lead is a reproductive toxicant with no known safe level
  • If it fails Moderate. Sulfation, gassing and water loss in high-antimony grids
  • Corrosion Moderate. Antimony leaves the positive grid and deposits on the negative plate, which the paper links to high water loss and self-discharge.

Quick facts: Pb-Sb

Key properties of Pb-Sb
PropertyValueBasis
Density6.68 g/cm³1 sourced value
Tensile strength34.8 to 40 MPa2 sourced values across conditions
Melting point630 °C1 sourced value

What is the density of Antimonial lead (Pb-Sb)?

Antimonial lead (Pb-Sb) has a density of 6.68 g/cm³. The source and test conditions are listed in the properties table on this page.

What is the melting point of Antimonial lead (Pb-Sb)?

Antimonial lead (Pb-Sb) has a melting point of 630 °C. The source and test conditions are listed in the properties table on this page.

What is the tensile strength of Antimonial lead (Pb-Sb)?

Antimonial lead (Pb-Sb) has a tensile strength of 34.8 to 40 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is Antimonial lead (Pb-Sb) used for?

Uses recorded in the sources include Cast positive and negative grids of lead-acid batteries (Pb-Sb grid alloys); Lead-acid batteries and US antimony and lead supply.

Why it exists

Antimonial lead is lead with a small amount of antimony. The antimony hardens the lead and gives it the castability needed for battery grids, but it does not stay put. Over the life of a lead-acid battery, antimony dissolves from the positive grid and deposits on the negative plate, which raises gassing, water loss and self-discharge. That trade is why automotive grid alloys are produced only up to 3.5 wt% Sb, and why arsenic and tin are added to keep the grid strong. USGS reports that antimonial lead and ammunition took 40% of US antimony use in 2025.

Where it's used

Lead-acid battery grids

The 2026 study says lead-antimony alloys are the common grid metal for lead-acid batteries, because antimony gives high charge-discharge performance and good castability. The paper's own tests used a Pb-3.5 wt% Sb grid alloy.

Lead-acid battery recycling

USGS reports that in the United States, antimonial lead recovered from spent lead-acid batteries was the source of secondary antimony. Recycling supplied 12% of US apparent consumption, and the lead-acid battery industry accounted for an estimated 67% of US lead consumption in 2025.

Ammunition

USGS says antimonial lead and ammunition took 40% of US antimony use in 2025. This profile does not use a specific ammunition product as a source, since none was read in this run.

Recipe

Pb-Sb alloy: lead with 1 to 12 wt% antimony; the grid alloys in the 2026 study are Pb-3.5 wt% Sb with arsenic or tin additions

Antimonial lead is lead (Pb) with a small addition of antimony (Sb), in this profile's scope 1 to 12 wt% Sb. Grid alloys in the 2026 study are Pb-3.5 wt% Sb with arsenic or tin added. Lead-antimony alloys are cast into grids for lead-acid batteries, and USGS says secondary antimony is recovered from antimonial lead made from spent lead-acid batteries.

What Pb-Sb is made of
IngredientShare of the weightWhat it does
Lead Pb not stated The matrix, most of the weight. Lead is soft, and the antimony added to it sets the strength and castability.
Antimony Sb not stated The hardening element, 1 to 12 wt% in scope. Higher antimony stiffens the grid but also drives antimony out of the positive grid over time.

Weight shares are as printed in the sources.

What it can do

Strength and stiffness

34.8 to 38.9 MPa

measured

A Pb-3.5 wt% Sb grid alloy with arsenic, as cast, had an ultimate tensile strength of 34.8 to 38.9 MPa, depending on the mold preheat temperature. Adding tin in place of some arsenic raised the strength to 38.9 to 40 MPa.

Stopping photons

5.549 cm2/g for lead at 100 keV

worked out from the formula

Lead alone attenuates 5.549 cm2/g at 100 keV, against 1.758 cm2/g for antimony, so the attenuation of an alloy depends on how much lead it contains. The NIST values are for the elements, not for an alloy sample.

Density of the element

6.68 g/cm3 (antimony)

measured

Antimony itself has a density of 6.68 g/cm3 at 20 degC in the PubChem record. The density of the lead alloy was not found in a checked source.

How it compares

The density and melting range of the lead-antimony alloy were not found in a checked source, so this profile compares the elements only. Pure antimony has a density of 6.68 g/cm3 and melts at 630.028 degC. Lead attenuates photons more strongly per gram at 100 keV (5.549 against 1.758 cm2/g for antimony). The 2026 study shows that tin in place of part of the arsenic keeps the grid stronger and more stable across casting temperatures.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementPb-SbSnPbBiInCdSbSnPbSAC305--GaInSnIn-Sn / In-AgSnZn and SnBiSn-Sb-CuPb alloys
Thermal behavior and safety
Melting point of antimony (element, for comparison)630 °C2231.9 °C327.5 °C271.3 °C156.6 °C321 °C630.7 °C183 °C217 °C70 °C98 °C-19 °C118 °C199 °C241 to 354 °C179 °C
Physical and electrical
Density of antimony (element, for comparison)6.68 g/cm³17310 kg/m311.34 g/cm³9.78 g/cm³7.31 g/cm³8.69 g/cm³6.68 g/cm³8.4 g/cm³7.35 g/cc10.15 g/cm³10.44 g/cm³6.44 g/cm³7.3 g/cm³7.27 g/cc7.39 g/cm³11.28 -
Other measurements
Mass attenuation coefficient at 100 keV, lead (element)5.549 cm²/g3no data5.549 cm²/gno datano datano datano datano datano datano datano datano datano datano datano datano data
Mass attenuation coefficient at 100 keV, antimony (element)1.758 cm²/g4no data5.549 cm²/gno datano datano datano datano datano datano datano datano datano datano datano datano data
Mass attenuation coefficient at 60 keV, lead (element)5.021 cm²/g5no data5.021 cm²/gno datano datano datano datano datano datano datano datano datano datano datano datano data
Mass attenuation coefficient at 60 keV, antimony (element)6.879 cm²/g6no data5.021 cm²/gno datano datano datano datano datano datano datano datano datano datano datano datano data
Mass attenuation coefficient at 80 keV, lead (element)2.419 cm²/g7no datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Mass attenuation coefficient at 80 keV, antimony (element)3.176 cm²/g8no datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Ultimate tensile strength, Pb-3.5Sb-0.23As grid alloy, as cast34.8 to 38.9 MPa9no datano datano data2.6 to 4.5 MPano datano data43 MPa39.58 MPano data44.1 MPano data12 MPa54.7 MPa77 MPa43 MPa
Elongation, Pb-3.5Sb-0.23As grid alloy, as cast7.2 to 8.2 %10no datano datano datano datano datano data40 %49 %no data37.5 %no datano data32.5 %18 %40 %
Ultimate tensile strength, Pb-3.5Sb-0.5Sn-0.16As grid alloy, as cast38.9 to 40 MPa11no datano datano data2.6 to 4.5 MPano datano data43 MPa39.58 MPano data44.1 MPano data12 MPa54.7 MPa77 MPa43 MPa
Elongation, Pb-3.5Sb-0.5Sn-0.16As grid alloy, as cast8.1 to 8.3 %12no datano datano datano datano datano data40 %49 %no data37.5 %no datano data32.5 %18 %40 %

Why choose it, and why not

Good for

  • Battery grids that need strength and castability from a small antimony addition. The 2026 study reports 34.8 to 40 MPa for a Pb-3.5 wt% Sb grid alloy.
  • A recycling chain that already exists. USGS says recycling supplied 12% of US apparent antimony consumption, recovered mainly as antimonial lead from spent batteries.

Watch out for

  • Antimony leaves the positive grid over time, raising gassing, water loss and self-discharge. The paper's automotive limit is 3.5 wt% Sb.
  • Lead's toxicity. The ECHA summary notes H360 for 84.4% of reports, and the WHO says there is no known safe blood lead concentration.
  • Corrosion behavior is only described qualitatively here. No corrosion rate was read in full text.

Antimonial lead is a cheap, castable lead alloy whose antimony gives the strength that battery grids need, but that antimony leaves the grid over time and costs water and battery life. The strength data here are for one grid alloy at 3.5 wt% Sb, and the alloy's density, melting range and hardness were not read, so this profile is a sourced draft, not a complete datasheet.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Density of antimony (element, for comparison)Value printed in the PubChem record for antimony (CID 5354495)form elemental antimony, 20 °C as printedbasis pure antimony, not the lead-antimony alloyThe record also prints 6.7, 6.69 and 6.684 g/cm3 in other entries. The density of the lead-antimony alloy itself was not found in a checked source.
2Melting point of antimony (element, for comparison)Value printed in the PubChem record for antimony (CID 5354495)form elemental antimony, gray form as printed in the recordbasis pure antimony, not the alloyThe record also prints 630 degC and 630.628 degC in other entries. The solidus and liquidus of Pb-Sb alloys were not found in a checked source.
3Mass attenuation coefficient at 100 keV, lead (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.1 MeVmedium elemental lead, Z = 82quantity mu/rho total, narrow beamPure lead is the upper reference: antimony adds much less attenuation per gram (see the antimony row). The energy is just above the lead K edge.
4Mass attenuation coefficient at 100 keV, antimony (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.1 MeVmedium elemental antimony, Z = 51quantity mu/rho total, narrow beam—
5Mass attenuation coefficient at 60 keV, lead (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.06 MeVmedium elemental lead, Z = 82quantity mu/rho total, narrow beam—
6Mass attenuation coefficient at 60 keV, antimony (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.06 MeVmedium elemental antimony, Z = 51quantity mu/rho total, narrow beam—
7Mass attenuation coefficient at 80 keV, lead (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.08 MeVmedium elemental lead, Z = 82quantity mu/rho total, narrow beam80 keV is just below the lead K edge at 88 keV, so the coefficient is lower here than at 100 keV.
8Mass attenuation coefficient at 80 keV, antimony (element)NIST XCOM-based tabulation (theory and data, not a measurement on an alloy sample)photon energy 0.08 MeVmedium elemental antimony, Z = 51quantity mu/rho total, narrow beam—
9Ultimate tensile strength, Pb-3.5Sb-0.23As grid alloy, as castRoom-temperature tensile test as reported in the paper; the range runs from the low to the high mold preheat temperaturealloy Pb-3.5 wt% Sb-0.23 wt% Asform as-cast grid alloy, room temperaturecooling casting mold preheated between 50 and 170 °Ctest TIRAtest 2300 at a crosshead speed of 10 mm/minStrength falls as mold preheat rises (decrease of 11.8 %). This is a research grid alloy with 3.5 wt% Sb, not the full 1 to 12 wt% range.
10Elongation, Pb-3.5Sb-0.23As grid alloy, as castRoom-temperature tensile test as reported in the paperalloy Pb-3.5 wt% Sb-0.23 wt% Asform as-cast grid alloy, room temperaturecooling casting mold preheated between 50 and 170 °Ctest TIRAtest 2300 at a crosshead speed of 10 mm/minElongation falls with mold preheat (decrease of 13.9 %), so the alloy becomes more brittle as the mold gets hotter.
11Ultimate tensile strength, Pb-3.5Sb-0.5Sn-0.16As grid alloy, as castRoom-temperature tensile test as reported in the paperalloy Pb-3.5 wt% Sb-0.5 wt% Sn-0.16 wt% Asform as-cast grid alloy, room temperaturecooling casting mold preheated between 75 and 165 °C for this alloytest TIRAtest 2300 at a crosshead speed of 10 mm/minTin in place of part of the arsenic lowers strength by only 2.8 % and gives more stable properties across mold temperatures than the arsenic-only alloy.
12Elongation, Pb-3.5Sb-0.5Sn-0.16As grid alloy, as castRoom-temperature tensile test as reported in the paperalloy Pb-3.5 wt% Sb-0.5 wt% Sn-0.16 wt% Asform as-cast grid alloy, room temperaturecooling casting mold preheated between 75 and 165 °C for this alloytest TIRAtest 2300 at a crosshead speed of 10 mm/minElongation rises slightly (2.4 %) with mold preheat for this alloy, the opposite trend to the arsenic-only alloy.

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Positive grid in sulfuric acid electrolyte of a lead-acid battery moderate Antimony leaves the positive grid and deposits on the negative plate, which the paper links to high water loss and self-discharge.1
Anodic dissolution of antimony in a lead-antimony grid not rated Grain refinement changes how the grid corrodes, which the 1988 Korean study explains through anodic dissolution of antimony.2
Corrosion details
#EnvironmentDetailsTest conditions
1 Positive grid in sulfuric acid electrolyte of a lead-acid battery The 2026 study says high-antimony lead alloys increase battery gassing during charging, leading to high water loss, and that the high discharge rate and short life of high-antimony batteries come from antimony dissolving from one electrode and depositing on the other. It also says high-antimony alloys are prone to sulfation and should not be left at low states of charge. basis qualitative statements in the introduction of a study of grid tensile properties; no corrosion rate, electrolyte concentration or test duration is given in the text readantimony range high-antimony versus medium (3.0 to 4.0 wt%) alloys
2 Anodic dissolution of antimony in a lead-antimony grid The abstract of the 1988 study says grain size depends on antimony content, can be reduced by adding selenium, and that the grain refining affected corrosion in terms of anodic dissolution of antimony. The abstract gives no corrosion rate, electrolyte or test time, so the rating is unknown. basis abstract only (the full text was not opened)alloy low-antimony lead alloys

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

Lead is the main hazard in this alloy, and the antimony adds harmful-if-swallowed and harmful-if-inhaled warnings.

Lead classification
PubChem's ECHA summary for lead carries signal word Danger, with H360 (may damage fertility or the unborn child) notified by 84.4% and H372 (damage to organs through prolonged exposure) by 50.5%.
Children
The WHO says there is no known safe blood lead concentration, and that young children may absorb up to 4 to 5 times as much lead as adults.
Antimony
The ECHA summary for antimony shows H301 for 18.2% and H302 for 23.4% of reports, and H332 for 26.9%, all with signal word Danger.

If it fails

The failures for this alloy happen inside the battery, rather than in the metal itself.

Gassing and water loss
The 2026 study says higher antimony raises gassing on charge and water loss, and that antimony dissolving from one plate and depositing on the other shortens battery life.
Cracking on casting
Cutting antimony too far causes hot cracks along grain boundaries during casting, so the low-antimony grid needs other additions.

Handling and recycling

Battery recycling
The WHO links dust and soil from battery recycling and mining to mass lead poisoning outbreaks, including child deaths in some countries.
Grid limit
The 2026 study says automotive grid alloys are produced only up to 3.5 wt% Sb, and medium alloys of 3.0 to 4.0 wt% Sb lower the transfer of antimony to the negative plate.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Sulfation, gassing and water loss in high-antimony gridsmoderate severityGrid antimony above the automotive limit of 3.5 wt%, or long standing at low state of chargeMore gassing on charge, high water loss that needs topping up, high self-discharge and a shorter battery life. The paper ties these to antimony moving from one electrode to the other.
Hot cracking when antimony is reduced in a cast gridmoderate severityLowering the antimony content of a cast Pb-Sb grid without other additionsSolidification in a coarse dendritic structure gives cracks along grain boundaries. The paper names this as the main casting difficulty, and says tin additions improve castability.

Side effects on surrounding parts

Side effects on surrounding parts
AffectsEffect
Negative plate and battery water balanceAntimony that dissolves from the positive grid deposits on the negative plate and drives self-discharge and water loss.
Ductility of the cast gridBrittle arsenic-containing phases form at grain boundaries in Pb-3.5Sb-As grids, lowering elongation; adding tin offsets most of this.

Handling and storage

  • Lead is a reproductive toxicant in the ECHA record (H360 notified by 84.4% of reports). Keep dust and fume out of work areas and follow the handling rules for lead in the lead profile.
  • Antimony is harmful if swallowed or inhaled in the ECHA record (H302, H332), so avoid dust and fume from antimony-bearing alloys.
  • WHO links exposure to lead-contaminated soil and dust from battery recycling and mining to outbreaks of mass lead poisoning, including child deaths in some countries.

Mitigations

  • Medium-antimony alloys (3.0 to 4.0 wt% Sb) reduce the transfer of antimony to the negative plate and cut water loss, especially when arsenic and tin are added to keep the grid strong at lower antimony.
  • Selenium addition reduces grain size in low-antimony alloys, according to the 1988 abstract.

Supply and geography

How common the raw materials are and where they come from.

Antimony

Top producers (2025)
China 36.4%, Russia 29.1%, Tajikistan 20%, Burma 4.1%
Critical mineral lists
US: listed, EU: listed
Recycling
USGS: secondary antimony was recovered mostly at secondary lead smelters as antimonial lead, most of which the lead-acid battery industry generated and then consumed. Recycling supplied 12% of estimated domestic apparent consumption in 2025.
Substitutes
Combinations of calcium, copper, selenium, sulfur and tin substitute for antimony in alloys for lead-acid batteries (USGS).