Minor nickel alloys (nickel-iron soft-magnetic and nickel-manganese grades) Ni-alloys

Nickel-iron soft-magnetic alloys (about 48 percent Ni, balance Fe) and nickel-manganese wire (Ni 212: at least 97.0 percent Ni, 1.5 to 2.20 percent Mn)

Also known as UNS N02212, EN 2.4110

Two nickel-base families have sourced data in this file.

3 sources · Updated 2026-10-26 · CC BY 4.0

Evidence level

2 of 5

Lab-measured

Magnetic strength

1.55 T saturation

Heat

Curie point 450 °C

Density

8.2 g/cm3 (Supra 50) and 8.86 g/cm3 (Ni 212)

Strength annealed

500 MPa tensile (Supra 50)

Nickel 212 wire

450 to 550 MPa tensile

Recipe, share of the weight

  • Ni not statedNickel
  • Fe not statedIron
  • Mn not statedManganese

Best for

Soft-magnetic strip that needs high saturation induction, and low-manganese nickel wire for lead-in and lead wire parts

Weakest at

Almost no data for nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron in this record, no corrosion or space-environment test data, and no hazard data read for these grades

Risk at a glance

  • People Low. No hazard data read for these grades
  • If it fails High. Loss of magnetic properties after final annealing
  • Corrosion No data. No corrosion data recorded

Quick facts: Ni-alloys

Key properties of Ni-alloys
PropertyValueBasis
Density8.2 to 8.86 g/cm³3 sourced values across conditions
Yield strength280 to 1,030 MPa2 sourced values across conditions
Tensile strength450 to 900 MPa3 sourced values across conditions
Thermal conductivity13 to 44 W/(m·K)2 sourced values across conditions
Thermal expansion (CTE)8 ppm/K1 sourced value
Melting point1,425 °C1 sourced value
Specific heat500 J/(kg·K)1 sourced value
Electrical resistivity1.1e-7 to 4.5e-7 Ω·m2 sourced values across conditions

What is the density of Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) has a density of 8.2 to 8.86 g/cm³. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the thermal conductivity of Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) has a thermal conductivity of 13 to 44 W/(m·K). The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the coefficient of thermal expansion of Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) has a coefficient of thermal expansion of 8 ppm/K. The source and test conditions are listed in the properties table on this page.

What is the melting point of Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) has a melting point of 1,425 °C. The source and test conditions are listed in the properties table on this page.

What is the yield strength of Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) has a yield strength of 280 to 1,030 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What are the other names and codes for Minor nickel alloys (Ni-alloys)?

Minor nickel alloys (Ni-alloys) is also written as UNS N02212, EN 2.4110. Each code is printed in the source listed beside it in the designations table.

What is Minor nickel alloys (Ni-alloys) used for?

Uses recorded in the sources include Soft-magnetic laminations, relay parts and stepping-motor parts (Magnifer 50 and Supra 50); Lead-in-wire fuses and lead wires in electrical components (Nickel 212).

Why it exists

These are nickel alloys in two families. The nickel-iron soft-magnetic alloys (VDM Magnifer 50 and IMPHY Supra 50, both about 48 percent nickel) are chosen for the highest saturation induction a nickel-iron alloy can reach: 1.55 T for Magnifer 50 and 1.50 T for Supra 50 at 10 Oe. Their Curie temperature is 450 °C. The nickel-manganese grade Nickel 212 (UNS N02212) is pure nickel with a small manganese addition, at least 97.0 percent nickel and 1.5 to 2.20 percent manganese, and is made for wire and strip. Pure nickel is covered in nickel.yaml, and nickel-base superalloys are in the other profiles in this family. Nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron are named in the brief but have no sourced values here.

Where it's used

Relays, stepping motors and laminations

VDM lists rotor and stator laminations, relay parts, stepping motors, chokes and magnetic valves as typical uses of Magnifer 50. IMPHY lists relays, sensors and shielding for Supra 50.

Lead wires and fuses

JLC Electromet says Nickel 212 is used as fuses for lead-in-wire components in light bulbs, as lead wires in electrical components, and as electrodes in glow discharge lamps.

Recipe

Nickel-iron soft-magnetic alloys (about 48 percent Ni, balance Fe) and nickel-manganese wire (Ni 212: at least 97.0 percent Ni, 1.5 to 2.20 percent Mn)

Nickel-iron soft-magnetic alloys contain about 48 percent Ni with iron as the balance (IMPHY and VDM). Magnifer 50 is final-annealed at 1050 to 1250 °C in dry hydrogen or cracked ammonia (VDM). Nickel 212 is at least 97.0 percent Ni with 1.5 to 2.20 percent Mn, and its other elements are maximum limits only (JLC). Process steps beyond heat treatment are not in these sources.

What Ni-alloys is made of
IngredientShare of the weightWhat it does
Nickel Ni not stated Base metal of the nickel-iron alloy, and the main element of Nickel 212
Iron Fe not stated Balance element in the soft-magnetic nickel-iron alloys
Manganese Mn not stated Small addition to raise the strength of Nickel 212 (JLC: improves strength)

Weight shares are as printed in the sources.

What it can do

Magnetic strength

1.55 T saturation

measured

Magnifer 50 has a saturation induction of 1.55 T. Supra 50 reaches 1.50 T at 10 Oe and has a maximum permeability of 200000 in direct current.

Heat

Curie point 450 °C

measured

Supra 50 loses its magnetism above 450 °C, and melts at 1425 °C.

Density

8.2 g/cm3 (Supra 50) and 8.86 g/cm3 (Ni 212)

measured

Supra 50 has a density of 8.2 g/cm3. Nickel 212 has 8.86 g/cm3, against 8.72 g/cm3 for Nickel 211.

Strength annealed

500 MPa tensile (Supra 50)

measured

Annealed Supra 50 has tensile strength 500 MPa, yield 280 MPa and elongation 35 percent. Hard temper gives 900 MPa tensile and 1030 MPa yield, with only 3 percent elongation.

Nickel 212 wire

450 to 550 MPa tensile

measured

Cold-drawn annealed Nickel 212 wire has tensile strength 450 to 550 MPa and elongation 20 to 30 percent at a 100 mm gauge length.

How it compares

The sources give no direct comparison between these grades and other nickel alloys. Among the two families, Supra 50 is the softer and heavier of the two nickel-iron grades (8.2 g/cm3 against no density printed for Magnifer 50), while Nickel 212 is the denser and more conductive nickel product, at 8.86 g/cm3 and 44 W/(m·K). Nothing here ranks the grades for any space use.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.

Benchmarks
MeasurementNi-alloysIN718 (UNS N07718)IN625 (UNS N06625)FeNi36Ni-MoC-22C-276 (UNS N10276)X (UNS N06002)UNS N07214H230 (UNS N06230)UNS N08800Alloy 825 (UNS N08825)Alloy 600 (UNS N06600, W.Nr. 2.4816)Alloy 601Alloy 617X-750 (UNS N07750)Fe-Ni-CoAlloy 400 (UNS N04400)K-500NiNi3Al, NiAlNiBe2UNS N07090 (W. Nr. 2.4632)UNS N07001
Thermal behavior and safety
Melting point, IMPHY Supra 501425 °C21260 °C1290 to 1350 °C1427 °C1370 to 1418 °C1357 to 1399 °C1323 to 1371 °C1260 to 1355 °C1355 to 1400 °C1301 to 1371 °C1357 to 1385 °C1370 to 1400 °C1354 to 1413 °C1360 to 1411 °C1330 to 1380 °C1393 to 1427 °C1450 °C1300 to 1350 °C1315 to 1350 °C1455 °Cno data1195 to 1325 °C1370 °C1330 to 1360 °C
Thermal conduction, IMPHY Supra 5013 W/(m·K)679 BTU·in/ft²·h·°F9.8 W/m°C72.85 Btu·in/(hr·ft²·°F)11.2 W/m.°C10.1 W/(m·K)10.5 W/m.°C9.2 W/(m·K)12 W/m-°C8.9 W/(m·°C)11.5 W/m°C11.1 W/(m·K)14.9 W/(m·K)11.2 W/(m·K)13.4 W/(m·K)83 Btu/in./hr/sq ft/°F17.5 W/m °K22 W/m°C17.5 W/m °C70.3 W/(m·K)no data48 W/(m·K)11.47 W/(m·K)19.1 W/(m·°C)
Specific heat, IMPHY Supra 50500 J/(kg·K)7435 J/kg °C410 J/(kg·K)515 J/(kg·K)373 J/kg.°C410 J/(kg·K)427 J/kg.°C486 J/(kg·K)452 J/kg-°C397 J/kg·°C460 J/kg·°C440 J/(kg·K)444 J/kg °C448 J/(kg·K)419 J/(kg·K)0.103 Btu/lb/°F500 J/(kg. K)427 J/kg°C419 J/kg °C456 J/(kg·K)no datano data446 J/(kg·K)no data
Thermal conductivity, Nickel 21244 W/(m·K)2279 BTU·in/ft²·h·°F9.8 W/m°C72.85 Btu·in/(hr·ft²·°F)11.2 W/m.°C10.1 W/(m·K)10.5 W/m.°C9.2 W/(m·K)12 W/m-°C8.9 W/(m·°C)11.5 W/m°C11.1 W/(m·K)14.9 W/(m·K)11.2 W/(m·K)13.4 W/(m·K)83 Btu/in./hr/sq ft/°F17.5 W/m °K22 W/m°C17.5 W/m °C70.3 W/(m·K)no data48 W/(m·K)11.47 W/(m·K)19.1 W/(m·°C)
Physical and electrical
Density, IMPHY Supra 50 (about 48 % Ni)8.2 g/cm³10.297 lb/in38.44 g/cm³8.05 g/cm³9.22 g/cm³8.69 g/cm³8.89 g/cm³8.22 g/cm³8.05 g/cm³8.97 g/cm³7.94 g/cm³8.14 g/cm³0.306 lb/in38.11 Mg/m38.36 g/cm³8.28 g/cm³8.36 g/cm³8.8 g/cm³8.45 g/cm³8.89 g/cm³7.5 g/cm³8.27 g/cm³8.18 g/cm³8.19 g/cm³
Electrical resistivity, IMPHY Supra 5045 µΩ·cm5725 ohm circ mil/ft129 µΩ-cm84 µΩ·cm1.37 μohm.m1.14 µΩ·m1.23 μohm.m114.8 µohm-cm135.9 µohm-cm125 µohm-m0.989 µΩ·m112 µΩ·cm1.03 µΩ·m1.18 µΩ·m1.22×10^-4 Ω·cm731 ohm circ mil/ft49 μΩcm0.511 µΩ·m0.615 µΩ·m0.096 µΩ·mno data< 28.7 µΩ·cm1.18 µΩ·m1.24 µΩ·m
Hardness, IMPHY Supra 50 annealed140 HV13no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Hardness, IMPHY Supra 50 hard temper250 HV17no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Density, Nickel 211 (for comparison with Ni 212)8.72 g/cm³200.297 lb/in38.44 g/cm³8.05 g/cm³9.22 g/cm³8.69 g/cm³8.89 g/cm³8.22 g/cm³8.05 g/cm³8.97 g/cm³7.94 g/cm³8.14 g/cm³0.306 lb/in38.11 Mg/m38.36 g/cm³8.28 g/cm³8.36 g/cm³8.8 g/cm³8.45 g/cm³8.89 g/cm³7.5 g/cm³8.27 g/cm³8.18 g/cm³8.19 g/cm³
Density, Nickel 2128.86 g/cm³210.297 lb/in38.44 g/cm³8.05 g/cm³9.22 g/cm³8.69 g/cm³8.89 g/cm³8.22 g/cm³8.05 g/cm³8.97 g/cm³7.94 g/cm³8.14 g/cm³0.306 lb/in38.11 Mg/m38.36 g/cm³8.28 g/cm³8.36 g/cm³8.8 g/cm³8.45 g/cm³8.89 g/cm³7.5 g/cm³8.27 g/cm³8.18 g/cm³8.19 g/cm³
Electrical resistivity, Nickel 212 at 20 degC11 µΩ·cm23725 ohm circ mil/ft129 µΩ-cm84 µΩ·cm1.37 μohm.m1.14 µΩ·m1.23 μohm.m114.8 µohm-cm135.9 µohm-cm125 µohm-m0.989 µΩ·m112 µΩ·cm1.03 µΩ·m1.18 µΩ·m1.22×10^-4 Ω·cm731 ohm circ mil/ft49 μΩcm0.511 µΩ·m0.615 µΩ·m0.096 µΩ·mno data< 28.7 µΩ·cm1.18 µΩ·m1.24 µΩ·m
Temperature behavior
Curie temperature, IMPHY Supra 50450 °C3-112 °C< -196 °C279 °Cno datano datano datano datano datano data-115 °C< -196 °C-124 °Cno datano datano data435 °C21 to 49 °C-65 °C360 °Cno datano datano datano data
Final annealing temperature, Magnifer 50 RG and TG1050 to 1250 °C19no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Other measurements
Thermal expansion, IMPHY Supra 508 ppm/K48.91 ppm/°F12.8 ppm/°C1.3 ppm/K10.6 μm/m.°C12.4 ppm/K11.2 μm/m.°C13.9 µm/(m·K)14.6 µm/m-°C11.8 ppm/K14.4 µm/m/°C13.9 ppm/K10.4 ppm/K13.75 µm/m/°C11.6 µm/(m·K)7 10-6 in./in./°F5.86 10-6/°C14.2 µm/m°C13.7 10-6/°C13.3 ppm/Kno data14.5 ppm/K12.7 µm/(m·K)14.3 µm/m·°C
Saturation induction, IMPHY Supra 501.5 T8no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Maximum permeability, IMPHY Supra 502×10^5 -9no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Tensile strength, IMPHY Supra 50 annealed500 MPa10201 ksi120 to 150 ksi65 ksi862 MPa690 to 950 MPa792 MPa760 MPa975 MPa837 MPa590 MPa662 MPa550 to 690 MPa675 MPa710 MPa> 165 ksi450 to 585 N/mm275 to 90 ksi621 to 758 MPa380 to 520 MPa2300 MPa660 to 900 MPa1175 MPa1027 MPa
Yield strength, IMPHY Supra 50 annealed280 MPa11171 ksi60 to 95 ksi40 ksi421 MPa> 310 MPa356 MPa340 MPa577 MPa417 MPa250 MPa338 MPa170 to 345 MPa292 MPa340 MPa> 105 ksi> 200 N/mm225 to 50 ksi276 to 414 MPa105 to 210 MPano data280 to 480 MPa752 MPa586 MPa
Elongation, IMPHY Supra 50 annealed35 %1226 %30 to 60 %35 %53 %> 45 %61 %48.9 %37.3 %47.3 %17 %45 %35 to 55 %46 %62 %> 20 %> 25 %35 to 60 %20 to 35 %40 to 55 %no data> 30 %30 %43 %
Tensile strength, IMPHY Supra 50 hard temper900 MPa14201 ksi120 to 150 ksi65 ksi862 MPa690 to 950 MPa792 MPa760 MPa975 MPa837 MPa590 MPa662 MPa550 to 690 MPa675 MPa710 MPa> 165 ksi450 to 585 N/mm275 to 90 ksi621 to 758 MPa380 to 520 MPa2300 MPa660 to 900 MPa1175 MPa1027 MPa
Yield strength, IMPHY Supra 50 hard temper1030 MPa15171 ksi60 to 95 ksi40 ksi421 MPa> 310 MPa356 MPa340 MPa577 MPa417 MPa250 MPa338 MPa170 to 345 MPa292 MPa340 MPa> 105 ksi> 200 N/mm225 to 50 ksi276 to 414 MPa105 to 210 MPano data280 to 480 MPa752 MPa586 MPa
Elongation, IMPHY Supra 50 hard temper3 %1626 %30 to 60 %35 %53 %> 45 %61 %48.9 %37.3 %47.3 %17 %45 %35 to 55 %46 %62 %> 20 %> 25 %35 to 60 %20 to 35 %40 to 55 %no data> 30 %30 %43 %
Saturation induction, Magnifer 50 (about 48 % Ni)1.55 T18no datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano datano data
Linear expansion coefficient, Nickel 212, 20 to 95 degC12.9 ppm/K248.91 ppm/°F12.8 ppm/°C1.3 ppm/K10.6 μm/m.°C12.4 ppm/K11.2 μm/m.°C13.9 µm/(m·K)14.6 µm/m-°C11.8 ppm/K14.4 µm/m/°C13.9 ppm/K10.4 ppm/K13.75 µm/m/°C11.6 µm/(m·K)7 10-6 in./in./°F5.86 10-6/°C14.2 µm/m°C13.7 10-6/°C13.3 ppm/Kno data14.5 ppm/K12.7 µm/(m·K)14.3 µm/m·°C
Tensile strength, Nickel 212 cold-drawn annealed wire450 to 550 MPa25201 ksi120 to 150 ksi65 ksi862 MPa690 to 950 MPa792 MPa760 MPa975 MPa837 MPa590 MPa662 MPa550 to 690 MPa675 MPa710 MPa> 165 ksi450 to 585 N/mm275 to 90 ksi621 to 758 MPa380 to 520 MPa2300 MPa660 to 900 MPa1175 MPa1027 MPa
Elongation, Nickel 212 cold-drawn annealed wire20 to 30 %2626 %30 to 60 %35 %53 %> 45 %61 %48.9 %37.3 %47.3 %17 %45 %35 to 55 %46 %62 %> 20 %> 25 %35 to 60 %20 to 35 %40 to 55 %no data> 30 %30 %43 %

Why choose it, and why not

Good for

  • High saturation induction in a strip alloy: 1.55 T for Magnifer 50 and 1.50 T for Supra 50.
  • Lightweight, electrically conductive nickel wire for lead-in and lead components, with 11 µΩ·cm resistivity for Nickel 212.

Watch out for

  • Almost no sourced data for nickel-cobalt, nickel-silicon, nickel-vanadium or nickel-boron in this file.
  • Only three datasheets and about 48 percent nickel grades; no true 50/50 permalloy datasheet was read.
  • No corrosion test values, hazard data or space-environment data for any grade here.

The nickel-iron soft-magnetic alloys (about 48 percent Ni) have sourced magnetic and mechanical values from two manufacturers, and Nickel 212 wire has sourced density, conductivity and tensile values from one. The four named binary systems (Ni-Co, Ni-Si, Ni-V, Ni-B) are unsourced here, and no space-environment or hazard data was found.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Other names and standards

The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.

Other names and standards
SystemCodes
UNSN02212
EN2.4110

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Density, IMPHY Supra 50 (about 48 % Ni)Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50 / Supra 50SP, cold rolled striptemperature not stated—
2Melting point, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50note the same table prints 2597 °F—
3Curie temperature, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50note the same table prints 842 °F—
4Thermal expansion, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 8 in the 10-6.K-1 columngrade IMPHY Supra 50temperature range not statedunit in source 10-6/K—
5Electrical resistivity, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50temperature not statedunit in source µΩ.cm—
6Thermal conduction, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50temperature not statedunit in source W/°Km—
7Specific heat, IMPHY Supra 50Value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50temperature not statedunit in source J.Kg-1.°K-1—
8Saturation induction, IMPHY Supra 50Typical magnetic value printed in the Aperam Alloys Imphy datasheet; the table prints 15000 G and 1,50 Tgrade IMPHY Supra 50, 0.35 mm stripfield 10 Oe (about 800 A/m)measurement direct current, typical value on ringsheat treatment 1150 °C in pure dry hydrogen, cooled at 50 to 100 °C per hour—
9Maximum permeability, IMPHY Supra 50Typical magnetic value printed in the Aperam Alloys Imphy datasheet (mu max column)grade IMPHY Supra 50, 0.35 mm stripmeasurement direct current, typical value on ringsheat treatment 1150 °C in pure dry hydrogen—
10Tensile strength, IMPHY Supra 50 annealedTypical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 500 MPa (72 ksi)grade IMPHY Supra 50, annealed tempergrain size ASTM 9testing typical values, tested to NF EN 10002—
11Yield strength, IMPHY Supra 50 annealedTypical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 280 MPa (41 ksi)grade IMPHY Supra 50, annealed temper—
12Elongation, IMPHY Supra 50 annealedTypical value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50, annealed temper—
13Hardness, IMPHY Supra 50 annealedTypical value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50, annealed temper—
14Tensile strength, IMPHY Supra 50 hard temperTypical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 900 MPa (130 ksi)grade IMPHY Supra 50, hard temper—
15Yield strength, IMPHY Supra 50 hard temperTypical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 1030 MPa (149 ksi)grade IMPHY Supra 50, hard temper—
16Elongation, IMPHY Supra 50 hard temperTypical value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50, hard temper—
17Hardness, IMPHY Supra 50 hard temperTypical value printed in the Aperam Alloys Imphy datasheet (April 2025)grade IMPHY Supra 50, hard temper—
18Saturation induction, Magnifer 50 (about 48 % Ni)Value stated in the VDM Material Data Sheet No. 9002 (August 2002) text, with the claim that it is the highest saturation induction obtainable with a nickel-iron alloygrade VDM Magnifer 50, all three variants (RG, TG, T)note a general statement in the data sheet text, not tied to one variant or test—
19Final annealing temperature, Magnifer 50 RG and TGValue printed in the VDM data sheet, Heat treatment sectiongrade Magnifer 50 RG and TGtime 2 to 8 hoursatmosphere dry hydrogen or cracked ammonia, dew point below -40 °C—
20Density, Nickel 211 (for comparison with Ni 212)Value printed in the JLC Electromet datasheet (May 2016), Physical properties tablegrade Nickel 211, UNS N02211, Mn 4.5 to 5.50 %temperature room temperature—
21Density, Nickel 212Value printed in the JLC Electromet datasheet (May 2016), Physical properties tablegrade Nickel 212, UNS N02212, Ni min 97.0 %, Mn 1.5 to 2.20 %temperature room temperature—
22Thermal conductivity, Nickel 212Value printed in the JLC Electromet datasheet (May 2016)grade Nickel 212temperature room temperatureunit in source W/m K—
23Electrical resistivity, Nickel 212 at 20 degCValue printed in the JLC Electromet datasheet (May 2016)grade Nickel 212temperature 20 °Cunit in source µΩ-cm—
24Linear expansion coefficient, Nickel 212, 20 to 95 degCValue printed in the JLC Electromet datasheet (May 2016)grade Nickel 212temperature range 20 to 95 °Cunit in source 10-6/K—
25Tensile strength, Nickel 212 cold-drawn annealed wireValue printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 rowgrade Nickel 212, cold drawn annealed wirebasis min and max printed as N/mm2, equal to MPa—
26Elongation, Nickel 212 cold-drawn annealed wireValue printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 rowgrade Nickel 212, cold drawn annealed wiregauge length 100 mm—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Cyclic damp heat (Magnifer 50 MH-BSo variant) not rated No corrosion rate or test result was read for any grade here; the datasheet only says one variant resists damp heat better.1
Corrosion details
#EnvironmentDetailsTest conditions
1 Cyclic damp heat (Magnifer 50 MH-BSo variant) VDM says the Magnifer 50 MH-BSo variant has increased corrosion resistance in a cyclic damp heat test and is used for stamped parts thicker than 0.5 mm. No measured value or test duration is printed in the text read. material Magnifer 50 MH-BSobasis qualitative statement in the datasheet

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

No safety data sheet or hazard statement was read for the nickel-iron or Ni 212 grades in this run. The nickel metal hazards are in nickel.yaml, not repeated here.

Handling
VDM gives annealing atmosphere rules and no health statement for Magnifer 50.

If it fails

The main failure route read in these datasheets is mechanical, not chemical.

Plastic deformation
VDM says any plastic deformation after final heat treatment causes a considerable loss of magnetic properties, so parts cannot be worked after final annealing.
Wrong anneal atmosphere
VDM says final annealing must be done in dry hydrogen or cracked ammonia at a dew point below -40 °C.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Loss of magnetic properties after final annealinghigh severityPlastic deformation of Magnifer 50 parts after the final heat treatmentVDM says any plastic deformation after the final heat treatment causes a considerable loss of magnetic properties, so parts cannot be bent or pressed after final annealing.

Handling and storage

  • VDM says Magnifer 50 must be final-annealed in dry hydrogen or cracked ammonia (dew point below -40 °C), and that intermediate soft annealing at 800 to 1000 °C is best done in hydrogen, cracked ammonia or a clean inert gas. No supplier safety data sheet for any of these grades was opened.

Supply and geography

How common the raw materials are and where they come from.

Nickel-iron soft-magnetic alloys and Nickel 212, producers and shares

No producer, country-share, critical-mineral or feedstock data was read for these grades in this run.

Recycling
Not read.