Minor nickel alloys (nickel-iron soft-magnetic and nickel-manganese grades) Ni-alloys
Nickel-iron soft-magnetic alloys (about 48 percent Ni, balance Fe) and nickel-manganese wire (Ni 212: at least 97.0 percent Ni, 1.5 to 2.20 percent Mn)
Also known as UNS N02212, EN 2.4110
Two nickel-base families have sourced data in this file.
Evidence level
2 of 5
Lab-measured
- 0Predicted only. No one has made it, or no measurement exists.
- 1Calculated. Only calculated or predicted values from sources.
- 2Lab-measured. Measured properties with their conditions stated.
- 3Space-relevant tests. Measured in conditions relevant to space, such as vacuum or atomic oxygen.
- 4Ground-qualified. Qualified for an application on the ground.
- 5Flown or field-proven. Flight or field results exist.
Magnetic strength
1.55 T saturation
Heat
Curie point 450 °C
Density
8.2 g/cm3 (Supra 50) and 8.86 g/cm3 (Ni 212)
Strength annealed
500 MPa tensile (Supra 50)
Nickel 212 wire
450 to 550 MPa tensile
Recipe, share of the weight
- Ni not statedNickel
- Fe not statedIron
- Mn not statedManganese
Best for
Soft-magnetic strip that needs high saturation induction, and low-manganese nickel wire for lead-in and lead wire parts
Weakest at
Almost no data for nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron in this record, no corrosion or space-environment test data, and no hazard data read for these grades
Risk at a glance
- People Low. No hazard data read for these grades
- If it fails High. Loss of magnetic properties after final annealing
- Corrosion No data. No corrosion data recorded
Quick facts: Ni-alloys
| Property | Value | Basis |
|---|---|---|
| Density | 8.2 to 8.86 g/cm³ | 3 sourced values across conditions |
| Yield strength | 280 to 1,030 MPa | 2 sourced values across conditions |
| Tensile strength | 450 to 900 MPa | 3 sourced values across conditions |
| Thermal conductivity | 13 to 44 W/(m·K) | 2 sourced values across conditions |
| Thermal expansion (CTE) | 8 ppm/K | 1 sourced value |
| Melting point | 1,425 °C | 1 sourced value |
| Specific heat | 500 J/(kg·K) | 1 sourced value |
| Electrical resistivity | 1.1e-7 to 4.5e-7 Ω·m | 2 sourced values across conditions |
What is the density of Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) has a density of 8.2 to 8.86 g/cm³. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.
What is the thermal conductivity of Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) has a thermal conductivity of 13 to 44 W/(m·K). The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.
What is the coefficient of thermal expansion of Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) has a coefficient of thermal expansion of 8 ppm/K. The source and test conditions are listed in the properties table on this page.
What is the melting point of Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) has a melting point of 1,425 °C. The source and test conditions are listed in the properties table on this page.
What is the yield strength of Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) has a yield strength of 280 to 1,030 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.
What are the other names and codes for Minor nickel alloys (Ni-alloys)?
Minor nickel alloys (Ni-alloys) is also written as UNS N02212, EN 2.4110. Each code is printed in the source listed beside it in the designations table.
What is Minor nickel alloys (Ni-alloys) used for?
Uses recorded in the sources include Soft-magnetic laminations, relay parts and stepping-motor parts (Magnifer 50 and Supra 50); Lead-in-wire fuses and lead wires in electrical components (Nickel 212).
Why it exists
These are nickel alloys in two families. The nickel-iron soft-magnetic alloys (VDM Magnifer 50 and IMPHY Supra 50, both about 48 percent nickel) are chosen for the highest saturation induction a nickel-iron alloy can reach: 1.55 T for Magnifer 50 and 1.50 T for Supra 50 at 10 Oe. Their Curie temperature is 450 °C. The nickel-manganese grade Nickel 212 (UNS N02212) is pure nickel with a small manganese addition, at least 97.0 percent nickel and 1.5 to 2.20 percent manganese, and is made for wire and strip. Pure nickel is covered in nickel.yaml, and nickel-base superalloys are in the other profiles in this family. Nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron are named in the brief but have no sourced values here.
Where it's used
Relays, stepping motors and laminations
VDM lists rotor and stator laminations, relay parts, stepping motors, chokes and magnetic valves as typical uses of Magnifer 50. IMPHY lists relays, sensors and shielding for Supra 50.
Lead wires and fuses
JLC Electromet says Nickel 212 is used as fuses for lead-in-wire components in light bulbs, as lead wires in electrical components, and as electrodes in glow discharge lamps.
Recipe
Nickel-iron soft-magnetic alloys (about 48 percent Ni, balance Fe) and nickel-manganese wire (Ni 212: at least 97.0 percent Ni, 1.5 to 2.20 percent Mn)
Nickel-iron soft-magnetic alloys contain about 48 percent Ni with iron as the balance (IMPHY and VDM). Magnifer 50 is final-annealed at 1050 to 1250 °C in dry hydrogen or cracked ammonia (VDM). Nickel 212 is at least 97.0 percent Ni with 1.5 to 2.20 percent Mn, and its other elements are maximum limits only (JLC). Process steps beyond heat treatment are not in these sources.
| Ingredient | Share of the weight | What it does |
|---|---|---|
| Nickel Ni | not stated | Base metal of the nickel-iron alloy, and the main element of Nickel 212 |
| Iron Fe | not stated | Balance element in the soft-magnetic nickel-iron alloys |
| Manganese Mn | not stated | Small addition to raise the strength of Nickel 212 (JLC: improves strength) |
Weight shares are as printed in the sources.
What it can do
Magnetic strength
1.55 T saturation
measured
Magnifer 50 has a saturation induction of 1.55 T. Supra 50 reaches 1.50 T at 10 Oe and has a maximum permeability of 200000 in direct current.
Heat
Curie point 450 °C
measured
Supra 50 loses its magnetism above 450 °C, and melts at 1425 °C.
Density
8.2 g/cm3 (Supra 50) and 8.86 g/cm3 (Ni 212)
measured
Supra 50 has a density of 8.2 g/cm3. Nickel 212 has 8.86 g/cm3, against 8.72 g/cm3 for Nickel 211.
Strength annealed
500 MPa tensile (Supra 50)
measured
Annealed Supra 50 has tensile strength 500 MPa, yield 280 MPa and elongation 35 percent. Hard temper gives 900 MPa tensile and 1030 MPa yield, with only 3 percent elongation.
Nickel 212 wire
450 to 550 MPa tensile
measured
Cold-drawn annealed Nickel 212 wire has tensile strength 450 to 550 MPa and elongation 20 to 30 percent at a 100 mm gauge length.
How it compares
The sources give no direct comparison between these grades and other nickel alloys. Among the two families, Supra 50 is the softer and heavier of the two nickel-iron grades (8.2 g/cm3 against no density printed for Magnifer 50), while Nickel 212 is the denser and more conductive nickel product, at 8.86 g/cm3 and 44 W/(m·K). Nothing here ranks the grades for any space use.
The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details. Other materials are shown beside it; each was measured under its own conditions, so open its page before comparing closely. Compare every grade in the family.
| Measurement | Ni-alloys | IN718 (UNS N07718) | IN625 (UNS N06625) | FeNi36 | Ni-Mo | C-22 | C-276 (UNS N10276) | X (UNS N06002) | UNS N07214 | H230 (UNS N06230) | UNS N08800 | Alloy 825 (UNS N08825) | Alloy 600 (UNS N06600, W.Nr. 2.4816) | Alloy 601 | Alloy 617 | X-750 (UNS N07750) | Fe-Ni-Co | Alloy 400 (UNS N04400) | K-500 | Ni | Ni3Al, NiAl | NiBe2 | UNS N07090 (W. Nr. 2.4632) | UNS N07001 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Thermal behavior and safety | ||||||||||||||||||||||||
| Melting point, IMPHY Supra 50 | 1425 °C2 | 1260 °C | 1290 to 1350 °C | 1427 °C | 1370 to 1418 °C | 1357 to 1399 °C | 1323 to 1371 °C | 1260 to 1355 °C | 1355 to 1400 °C | 1301 to 1371 °C | 1357 to 1385 °C | 1370 to 1400 °C | 1354 to 1413 °C | 1360 to 1411 °C | 1330 to 1380 °C | 1393 to 1427 °C | 1450 °C | 1300 to 1350 °C | 1315 to 1350 °C | 1455 °C | no data | 1195 to 1325 °C | 1370 °C | 1330 to 1360 °C |
| Thermal conduction, IMPHY Supra 50 | 13 W/(m·K)6 | 79 BTU·in/ft²·h·°F | 9.8 W/m°C | 72.85 Btu·in/(hr·ft²·°F) | 11.2 W/m.°C | 10.1 W/(m·K) | 10.5 W/m.°C | 9.2 W/(m·K) | 12 W/m-°C | 8.9 W/(m·°C) | 11.5 W/m°C | 11.1 W/(m·K) | 14.9 W/(m·K) | 11.2 W/(m·K) | 13.4 W/(m·K) | 83 Btu/in./hr/sq ft/°F | 17.5 W/m °K | 22 W/m°C | 17.5 W/m °C | 70.3 W/(m·K) | no data | 48 W/(m·K) | 11.47 W/(m·K) | 19.1 W/(m·°C) |
| Specific heat, IMPHY Supra 50 | 500 J/(kg·K)7 | 435 J/kg °C | 410 J/(kg·K) | 515 J/(kg·K) | 373 J/kg.°C | 410 J/(kg·K) | 427 J/kg.°C | 486 J/(kg·K) | 452 J/kg-°C | 397 J/kg·°C | 460 J/kg·°C | 440 J/(kg·K) | 444 J/kg °C | 448 J/(kg·K) | 419 J/(kg·K) | 0.103 Btu/lb/°F | 500 J/(kg. K) | 427 J/kg°C | 419 J/kg °C | 456 J/(kg·K) | no data | no data | 446 J/(kg·K) | no data |
| Thermal conductivity, Nickel 212 | 44 W/(m·K)22 | 79 BTU·in/ft²·h·°F | 9.8 W/m°C | 72.85 Btu·in/(hr·ft²·°F) | 11.2 W/m.°C | 10.1 W/(m·K) | 10.5 W/m.°C | 9.2 W/(m·K) | 12 W/m-°C | 8.9 W/(m·°C) | 11.5 W/m°C | 11.1 W/(m·K) | 14.9 W/(m·K) | 11.2 W/(m·K) | 13.4 W/(m·K) | 83 Btu/in./hr/sq ft/°F | 17.5 W/m °K | 22 W/m°C | 17.5 W/m °C | 70.3 W/(m·K) | no data | 48 W/(m·K) | 11.47 W/(m·K) | 19.1 W/(m·°C) |
| Physical and electrical | ||||||||||||||||||||||||
| Density, IMPHY Supra 50 (about 48 % Ni) | 8.2 g/cm³1 | 0.297 lb/in3 | 8.44 g/cm³ | 8.05 g/cm³ | 9.22 g/cm³ | 8.69 g/cm³ | 8.89 g/cm³ | 8.22 g/cm³ | 8.05 g/cm³ | 8.97 g/cm³ | 7.94 g/cm³ | 8.14 g/cm³ | 0.306 lb/in3 | 8.11 Mg/m3 | 8.36 g/cm³ | 8.28 g/cm³ | 8.36 g/cm³ | 8.8 g/cm³ | 8.45 g/cm³ | 8.89 g/cm³ | 7.5 g/cm³ | 8.27 g/cm³ | 8.18 g/cm³ | 8.19 g/cm³ |
| Electrical resistivity, IMPHY Supra 50 | 45 µΩ·cm5 | 725 ohm circ mil/ft | 129 µΩ-cm | 84 µΩ·cm | 1.37 μohm.m | 1.14 µΩ·m | 1.23 μohm.m | 114.8 µohm-cm | 135.9 µohm-cm | 125 µohm-m | 0.989 µΩ·m | 112 µΩ·cm | 1.03 µΩ·m | 1.18 µΩ·m | 1.22×10^-4 Ω·cm | 731 ohm circ mil/ft | 49 μΩcm | 0.511 µΩ·m | 0.615 µΩ·m | 0.096 µΩ·m | no data | < 28.7 µΩ·cm | 1.18 µΩ·m | 1.24 µΩ·m |
| Hardness, IMPHY Supra 50 annealed | 140 HV13 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Hardness, IMPHY Supra 50 hard temper | 250 HV17 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Density, Nickel 211 (for comparison with Ni 212) | 8.72 g/cm³20 | 0.297 lb/in3 | 8.44 g/cm³ | 8.05 g/cm³ | 9.22 g/cm³ | 8.69 g/cm³ | 8.89 g/cm³ | 8.22 g/cm³ | 8.05 g/cm³ | 8.97 g/cm³ | 7.94 g/cm³ | 8.14 g/cm³ | 0.306 lb/in3 | 8.11 Mg/m3 | 8.36 g/cm³ | 8.28 g/cm³ | 8.36 g/cm³ | 8.8 g/cm³ | 8.45 g/cm³ | 8.89 g/cm³ | 7.5 g/cm³ | 8.27 g/cm³ | 8.18 g/cm³ | 8.19 g/cm³ |
| Density, Nickel 212 | 8.86 g/cm³21 | 0.297 lb/in3 | 8.44 g/cm³ | 8.05 g/cm³ | 9.22 g/cm³ | 8.69 g/cm³ | 8.89 g/cm³ | 8.22 g/cm³ | 8.05 g/cm³ | 8.97 g/cm³ | 7.94 g/cm³ | 8.14 g/cm³ | 0.306 lb/in3 | 8.11 Mg/m3 | 8.36 g/cm³ | 8.28 g/cm³ | 8.36 g/cm³ | 8.8 g/cm³ | 8.45 g/cm³ | 8.89 g/cm³ | 7.5 g/cm³ | 8.27 g/cm³ | 8.18 g/cm³ | 8.19 g/cm³ |
| Electrical resistivity, Nickel 212 at 20 degC | 11 µΩ·cm23 | 725 ohm circ mil/ft | 129 µΩ-cm | 84 µΩ·cm | 1.37 μohm.m | 1.14 µΩ·m | 1.23 μohm.m | 114.8 µohm-cm | 135.9 µohm-cm | 125 µohm-m | 0.989 µΩ·m | 112 µΩ·cm | 1.03 µΩ·m | 1.18 µΩ·m | 1.22×10^-4 Ω·cm | 731 ohm circ mil/ft | 49 μΩcm | 0.511 µΩ·m | 0.615 µΩ·m | 0.096 µΩ·m | no data | < 28.7 µΩ·cm | 1.18 µΩ·m | 1.24 µΩ·m |
| Temperature behavior | ||||||||||||||||||||||||
| Curie temperature, IMPHY Supra 50 | 450 °C3 | -112 °C | < -196 °C | 279 °C | no data | no data | no data | no data | no data | no data | -115 °C | < -196 °C | -124 °C | no data | no data | no data | 435 °C | 21 to 49 °C | -65 °C | 360 °C | no data | no data | no data | no data |
| Final annealing temperature, Magnifer 50 RG and TG | 1050 to 1250 °C19 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Other measurements | ||||||||||||||||||||||||
| Thermal expansion, IMPHY Supra 50 | 8 ppm/K4 | 8.91 ppm/°F | 12.8 ppm/°C | 1.3 ppm/K | 10.6 μm/m.°C | 12.4 ppm/K | 11.2 μm/m.°C | 13.9 µm/(m·K) | 14.6 µm/m-°C | 11.8 ppm/K | 14.4 µm/m/°C | 13.9 ppm/K | 10.4 ppm/K | 13.75 µm/m/°C | 11.6 µm/(m·K) | 7 10-6 in./in./°F | 5.86 10-6/°C | 14.2 µm/m°C | 13.7 10-6/°C | 13.3 ppm/K | no data | 14.5 ppm/K | 12.7 µm/(m·K) | 14.3 µm/m·°C |
| Saturation induction, IMPHY Supra 50 | 1.5 T8 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Maximum permeability, IMPHY Supra 50 | 2×10^5 -9 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Tensile strength, IMPHY Supra 50 annealed | 500 MPa10 | 201 ksi | 120 to 150 ksi | 65 ksi | 862 MPa | 690 to 950 MPa | 792 MPa | 760 MPa | 975 MPa | 837 MPa | 590 MPa | 662 MPa | 550 to 690 MPa | 675 MPa | 710 MPa | > 165 ksi | 450 to 585 N/mm2 | 75 to 90 ksi | 621 to 758 MPa | 380 to 520 MPa | 2300 MPa | 660 to 900 MPa | 1175 MPa | 1027 MPa |
| Yield strength, IMPHY Supra 50 annealed | 280 MPa11 | 171 ksi | 60 to 95 ksi | 40 ksi | 421 MPa | > 310 MPa | 356 MPa | 340 MPa | 577 MPa | 417 MPa | 250 MPa | 338 MPa | 170 to 345 MPa | 292 MPa | 340 MPa | > 105 ksi | > 200 N/mm2 | 25 to 50 ksi | 276 to 414 MPa | 105 to 210 MPa | no data | 280 to 480 MPa | 752 MPa | 586 MPa |
| Elongation, IMPHY Supra 50 annealed | 35 %12 | 26 % | 30 to 60 % | 35 % | 53 % | > 45 % | 61 % | 48.9 % | 37.3 % | 47.3 % | 17 % | 45 % | 35 to 55 % | 46 % | 62 % | > 20 % | > 25 % | 35 to 60 % | 20 to 35 % | 40 to 55 % | no data | > 30 % | 30 % | 43 % |
| Tensile strength, IMPHY Supra 50 hard temper | 900 MPa14 | 201 ksi | 120 to 150 ksi | 65 ksi | 862 MPa | 690 to 950 MPa | 792 MPa | 760 MPa | 975 MPa | 837 MPa | 590 MPa | 662 MPa | 550 to 690 MPa | 675 MPa | 710 MPa | > 165 ksi | 450 to 585 N/mm2 | 75 to 90 ksi | 621 to 758 MPa | 380 to 520 MPa | 2300 MPa | 660 to 900 MPa | 1175 MPa | 1027 MPa |
| Yield strength, IMPHY Supra 50 hard temper | 1030 MPa15 | 171 ksi | 60 to 95 ksi | 40 ksi | 421 MPa | > 310 MPa | 356 MPa | 340 MPa | 577 MPa | 417 MPa | 250 MPa | 338 MPa | 170 to 345 MPa | 292 MPa | 340 MPa | > 105 ksi | > 200 N/mm2 | 25 to 50 ksi | 276 to 414 MPa | 105 to 210 MPa | no data | 280 to 480 MPa | 752 MPa | 586 MPa |
| Elongation, IMPHY Supra 50 hard temper | 3 %16 | 26 % | 30 to 60 % | 35 % | 53 % | > 45 % | 61 % | 48.9 % | 37.3 % | 47.3 % | 17 % | 45 % | 35 to 55 % | 46 % | 62 % | > 20 % | > 25 % | 35 to 60 % | 20 to 35 % | 40 to 55 % | no data | > 30 % | 30 % | 43 % |
| Saturation induction, Magnifer 50 (about 48 % Ni) | 1.55 T18 | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data | no data |
| Linear expansion coefficient, Nickel 212, 20 to 95 degC | 12.9 ppm/K24 | 8.91 ppm/°F | 12.8 ppm/°C | 1.3 ppm/K | 10.6 μm/m.°C | 12.4 ppm/K | 11.2 μm/m.°C | 13.9 µm/(m·K) | 14.6 µm/m-°C | 11.8 ppm/K | 14.4 µm/m/°C | 13.9 ppm/K | 10.4 ppm/K | 13.75 µm/m/°C | 11.6 µm/(m·K) | 7 10-6 in./in./°F | 5.86 10-6/°C | 14.2 µm/m°C | 13.7 10-6/°C | 13.3 ppm/K | no data | 14.5 ppm/K | 12.7 µm/(m·K) | 14.3 µm/m·°C |
| Tensile strength, Nickel 212 cold-drawn annealed wire | 450 to 550 MPa25 | 201 ksi | 120 to 150 ksi | 65 ksi | 862 MPa | 690 to 950 MPa | 792 MPa | 760 MPa | 975 MPa | 837 MPa | 590 MPa | 662 MPa | 550 to 690 MPa | 675 MPa | 710 MPa | > 165 ksi | 450 to 585 N/mm2 | 75 to 90 ksi | 621 to 758 MPa | 380 to 520 MPa | 2300 MPa | 660 to 900 MPa | 1175 MPa | 1027 MPa |
| Elongation, Nickel 212 cold-drawn annealed wire | 20 to 30 %26 | 26 % | 30 to 60 % | 35 % | 53 % | > 45 % | 61 % | 48.9 % | 37.3 % | 47.3 % | 17 % | 45 % | 35 to 55 % | 46 % | 62 % | > 20 % | > 25 % | 35 to 60 % | 20 to 35 % | 40 to 55 % | no data | > 30 % | 30 % | 43 % |
Why choose it, and why not
Good for
- High saturation induction in a strip alloy: 1.55 T for Magnifer 50 and 1.50 T for Supra 50.
- Lightweight, electrically conductive nickel wire for lead-in and lead components, with 11 µΩ·cm resistivity for Nickel 212.
Watch out for
- Almost no sourced data for nickel-cobalt, nickel-silicon, nickel-vanadium or nickel-boron in this file.
- Only three datasheets and about 48 percent nickel grades; no true 50/50 permalloy datasheet was read.
- No corrosion test values, hazard data or space-environment data for any grade here.
The nickel-iron soft-magnetic alloys (about 48 percent Ni) have sourced magnetic and mechanical values from two manufacturers, and Nickel 212 wire has sourced density, conductivity and tensile values from one. The four named binary systems (Ni-Co, Ni-Si, Ni-V, Ni-B) are unsourced here, and no space-environment or hazard data was found.
Technical details
For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.
Other names and standards
The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.
| System | Codes |
|---|---|
| UNS | N02212 |
| EN | 2.4110 |
Notes
The method, full conditions and any caveat for the numbered rows above.
| # | Measurement | Method | Conditions | Caveat |
|---|---|---|---|---|
| 1 | Density, IMPHY Supra 50 (about 48 % Ni) | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50 / Supra 50SP, cold rolled striptemperature not stated | — |
| 2 | Melting point, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50note the same table prints 2597 °F | — |
| 3 | Curie temperature, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50note the same table prints 842 °F | — |
| 4 | Thermal expansion, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 8 in the 10-6.K-1 column | grade IMPHY Supra 50temperature range not statedunit in source 10-6/K | — |
| 5 | Electrical resistivity, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50temperature not statedunit in source µΩ.cm | — |
| 6 | Thermal conduction, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50temperature not statedunit in source W/°Km | — |
| 7 | Specific heat, IMPHY Supra 50 | Value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50temperature not statedunit in source J.Kg-1.°K-1 | — |
| 8 | Saturation induction, IMPHY Supra 50 | Typical magnetic value printed in the Aperam Alloys Imphy datasheet; the table prints 15000 G and 1,50 T | grade IMPHY Supra 50, 0.35 mm stripfield 10 Oe (about 800 A/m)measurement direct current, typical value on ringsheat treatment 1150 °C in pure dry hydrogen, cooled at 50 to 100 °C per hour | — |
| 9 | Maximum permeability, IMPHY Supra 50 | Typical magnetic value printed in the Aperam Alloys Imphy datasheet (mu max column) | grade IMPHY Supra 50, 0.35 mm stripmeasurement direct current, typical value on ringsheat treatment 1150 °C in pure dry hydrogen | — |
| 10 | Tensile strength, IMPHY Supra 50 annealed | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 500 MPa (72 ksi) | grade IMPHY Supra 50, annealed tempergrain size ASTM 9testing typical values, tested to NF EN 10002 | — |
| 11 | Yield strength, IMPHY Supra 50 annealed | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 280 MPa (41 ksi) | grade IMPHY Supra 50, annealed temper | — |
| 12 | Elongation, IMPHY Supra 50 annealed | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50, annealed temper | — |
| 13 | Hardness, IMPHY Supra 50 annealed | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50, annealed temper | — |
| 14 | Tensile strength, IMPHY Supra 50 hard temper | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 900 MPa (130 ksi) | grade IMPHY Supra 50, hard temper | — |
| 15 | Yield strength, IMPHY Supra 50 hard temper | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 1030 MPa (149 ksi) | grade IMPHY Supra 50, hard temper | — |
| 16 | Elongation, IMPHY Supra 50 hard temper | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50, hard temper | — |
| 17 | Hardness, IMPHY Supra 50 hard temper | Typical value printed in the Aperam Alloys Imphy datasheet (April 2025) | grade IMPHY Supra 50, hard temper | — |
| 18 | Saturation induction, Magnifer 50 (about 48 % Ni) | Value stated in the VDM Material Data Sheet No. 9002 (August 2002) text, with the claim that it is the highest saturation induction obtainable with a nickel-iron alloy | grade VDM Magnifer 50, all three variants (RG, TG, T)note a general statement in the data sheet text, not tied to one variant or test | — |
| 19 | Final annealing temperature, Magnifer 50 RG and TG | Value printed in the VDM data sheet, Heat treatment section | grade Magnifer 50 RG and TGtime 2 to 8 hoursatmosphere dry hydrogen or cracked ammonia, dew point below -40 °C | — |
| 20 | Density, Nickel 211 (for comparison with Ni 212) | Value printed in the JLC Electromet datasheet (May 2016), Physical properties table | grade Nickel 211, UNS N02211, Mn 4.5 to 5.50 %temperature room temperature | — |
| 21 | Density, Nickel 212 | Value printed in the JLC Electromet datasheet (May 2016), Physical properties table | grade Nickel 212, UNS N02212, Ni min 97.0 %, Mn 1.5 to 2.20 %temperature room temperature | — |
| 22 | Thermal conductivity, Nickel 212 | Value printed in the JLC Electromet datasheet (May 2016) | grade Nickel 212temperature room temperatureunit in source W/m K | — |
| 23 | Electrical resistivity, Nickel 212 at 20 degC | Value printed in the JLC Electromet datasheet (May 2016) | grade Nickel 212temperature 20 °Cunit in source µΩ-cm | — |
| 24 | Linear expansion coefficient, Nickel 212, 20 to 95 degC | Value printed in the JLC Electromet datasheet (May 2016) | grade Nickel 212temperature range 20 to 95 °Cunit in source 10-6/K | — |
| 25 | Tensile strength, Nickel 212 cold-drawn annealed wire | Value printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 row | grade Nickel 212, cold drawn annealed wirebasis min and max printed as N/mm2, equal to MPa | — |
| 26 | Elongation, Nickel 212 cold-drawn annealed wire | Value printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 row | grade Nickel 212, cold drawn annealed wiregauge length 100 mm | — |
Corrosion and compatibility
What happens when it meets other materials and environments.
| Environment | Concern | What happens |
|---|---|---|
| Cyclic damp heat (Magnifer 50 MH-BSo variant) | not rated | No corrosion rate or test result was read for any grade here; the datasheet only says one variant resists damp heat better.1 |
| # | Environment | Details | Test conditions |
|---|---|---|---|
| 1 | Cyclic damp heat (Magnifer 50 MH-BSo variant) | VDM says the Magnifer 50 MH-BSo variant has increased corrosion resistance in a cyclic damp heat test and is used for stamped parts thicker than 0.5 mm. No measured value or test duration is printed in the text read. | material Magnifer 50 MH-BSobasis qualitative statement in the datasheet |
Risks and side effects
Hazards to people, what happens when a cell overheats, and how the material is handled and stored.
For people
No safety data sheet or hazard statement was read for the nickel-iron or Ni 212 grades in this run. The nickel metal hazards are in nickel.yaml, not repeated here.
- Handling
- VDM gives annealing atmosphere rules and no health statement for Magnifer 50.
If it fails
The main failure route read in these datasheets is mechanical, not chemical.
- Plastic deformation
- VDM says any plastic deformation after final heat treatment causes a considerable loss of magnetic properties, so parts cannot be worked after final annealing.
- Wrong anneal atmosphere
- VDM says final annealing must be done in dry hydrogen or cracked ammonia at a dew point below -40 °C.
Test details
The original wording and numbers from the sources, for readers who want them.
Failure risks
| Failure | Trigger and consequence |
|---|---|
| Loss of magnetic properties after final annealinghigh severity | Plastic deformation of Magnifer 50 parts after the final heat treatmentVDM says any plastic deformation after the final heat treatment causes a considerable loss of magnetic properties, so parts cannot be bent or pressed after final annealing. |
Handling and storage
- VDM says Magnifer 50 must be final-annealed in dry hydrogen or cracked ammonia (dew point below -40 °C), and that intermediate soft annealing at 800 to 1000 °C is best done in hydrogen, cracked ammonia or a clean inert gas. No supplier safety data sheet for any of these grades was opened.
Supply and geography
How common the raw materials are and where they come from.
Nickel-iron soft-magnetic alloys and Nickel 212, producers and shares
No producer, country-share, critical-mineral or feedstock data was read for these grades in this run.
- Recycling
- Not read.
Documents
Datasheets, safety data sheets, papers and standards you can open.
| Document | Type | Year |
|---|---|---|
| Aperam Alloys Imphy: IMPHY SUPRA 50 and SUPRA 50SP cold rolled strip datasheet | datasheet | 2025 |
| VDM Metals Material Data Sheet No. 9002: Magnifer 50 (copy hosted on alloy59.de) | datasheet | 2002 |
| JLC Electromet: Nickel-Manganese Alloys (Ni 211 and Ni 212) data sheet | datasheet | 2016 |
Full record
The complete spore, as stored. Free to reuse under CC-BY-4.0. Images keep the licence shown with each one.
Show the full YAML
spore: profile
id: nickel-minor-alloys
spore_version: 0.2
family: nickel-alloys
name: Minor nickel alloys (nickel-iron soft-magnetic and nickel-manganese grades)
abbreviation: Ni-alloys
role: soft-magnetic strip alloy and low-manganese nickel wire
category: metals
type: nickel-superalloys
summary: |
Two nickel-base families have sourced data in this file. Nickel-iron soft-magnetic alloys with about 48 percent nickel (VDM Magnifer 50 and IMPHY Supra 50) have a saturation induction of 1.50 to 1.55 T, a Curie temperature of 450 degC and a density of 8.2 g/cm3 for Supra 50. Nickel 212 (UNS N02212, DIN 2.4110) is a nickel-manganese wire and strip grade with at least 97.0 percent nickel and 1.5 to 2.20 percent manganese, density 8.86 g/cm3 and electrical resistivity 11 uOhm.cm at 20 degC. No sourced values were found for nickel-cobalt, nickel-silicon, nickel-vanadium or nickel-boron, and no true 50/50 nickel-iron datasheet was read.
best_for: Soft-magnetic strip that needs high saturation induction, and low-manganese nickel wire for lead-in and lead wire parts
weakest_at: Almost no data for nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron in this record, no corrosion or space-environment test data, and no hazard data read for these grades
identity:
formula: 'Nickel-iron soft-magnetic alloys (about 48 percent Ni, balance Fe) and nickel-manganese wire (Ni 212: at least 97.0 percent Ni, 1.5 to 2.20 percent Mn)'
source: jlc-ni211-212
where: Nominal Chemical Composition table (Ni 212 row); IMPHY Chemical composition table (Ni typical value 48, Fe bal)
designations:
- system: UNS
code: N02212
source: jlc-ni211-212
where: Specifications table, UNS designation column (Ni 212 row)
- system: EN
code: '2.4110'
source: jlc-ni211-212
where: Specifications table, Werkstoff Nr column (Ni 212 row)
tags:
environments: []
stresses: []
applications:
- electronics-and-chips
- mechanisms
properties:
- benchmark: density
label: Density, IMPHY Supra 50 (about 48 % Ni)
value: 8.2
unit: g/cm3
scope: material
conditions:
grade: IMPHY Supra 50 / Supra 50SP, cold rolled strip
temperature: not stated
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Density column
- benchmark: melting_point
label: Melting point, IMPHY Supra 50
value: 1425
unit: °C
scope: material
conditions:
grade: IMPHY Supra 50
note: the same table prints 2597 °F
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Melting T column
- benchmark: curie_temperature
label: Curie temperature, IMPHY Supra 50
value: 450
unit: °C
scope: material
conditions:
grade: IMPHY Supra 50
note: the same table prints 842 °F
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Curie T column
- benchmark: cte
label: Thermal expansion, IMPHY Supra 50
value: 8
unit: ppm/K
scope: material
conditions:
grade: IMPHY Supra 50
temperature_range: not stated
unit_in_source: 10-6/K
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 8 in the 10-6.K-1 column
status: ground
source: imphy-supra50
where: Physical properties table, Thermal expansion column
- benchmark: electrical_resistivity
label: Electrical resistivity, IMPHY Supra 50
value: 45
unit: µΩ·cm
scope: material
conditions:
grade: IMPHY Supra 50
temperature: not stated
unit_in_source: µΩ.cm
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Resistivity column
- benchmark: thermal_conductivity
label: Thermal conduction, IMPHY Supra 50
value: 13
unit: W/(m·K)
scope: material
conditions:
grade: IMPHY Supra 50
temperature: not stated
unit_in_source: W/°Km
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Thermal conduction column
- benchmark: specific_heat
label: Specific heat, IMPHY Supra 50
value: 500
unit: J/(kg·K)
scope: material
conditions:
grade: IMPHY Supra 50
temperature: not stated
unit_in_source: J.Kg-1.°K-1
method: Value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Physical properties table, Specific heat column
- benchmark: saturation_induction
label: Saturation induction, IMPHY Supra 50
value: 1.5
unit: T
scope: material
conditions:
grade: IMPHY Supra 50, 0.35 mm strip
field: 10 Oe (about 800 A/m)
measurement: direct current, typical value on rings
heat_treatment: 1150 °C in pure dry hydrogen, cooled at 50 to 100 °C per hour
method: Typical magnetic value printed in the Aperam Alloys Imphy datasheet; the table prints 15000 G and 1,50 T
status: ground
source: imphy-supra50
where: Magnetic properties table, Direct Current row, Saturation induction column
- benchmark: permeability_max
label: Maximum permeability, IMPHY Supra 50
value: 200000
unit: '-'
scope: material
conditions:
grade: IMPHY Supra 50, 0.35 mm strip
measurement: direct current, typical value on rings
heat_treatment: 1150 °C in pure dry hydrogen
method: Typical magnetic value printed in the Aperam Alloys Imphy datasheet (mu max column)
status: ground
source: imphy-supra50
where: Magnetic properties table, Direct Current row, Permeability column (mu max 200000)
- benchmark: ultimate_tensile_strength
label: Tensile strength, IMPHY Supra 50 annealed
value: 500
unit: MPa
scope: material
conditions:
grade: IMPHY Supra 50, annealed temper
grain_size: ASTM 9
testing: typical values, tested to NF EN 10002
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 500 MPa (72 ksi)
status: ground
source: imphy-supra50
where: Mechanical properties table, Annealed row, Tensile strength column
- benchmark: yield_strength
label: Yield strength, IMPHY Supra 50 annealed
value: 280
unit: MPa
scope: material
conditions:
grade: IMPHY Supra 50, annealed temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 280 MPa (41 ksi)
status: ground
source: imphy-supra50
where: Mechanical properties table, Annealed row, Yield strength column
- benchmark: elongation
label: Elongation, IMPHY Supra 50 annealed
value: 35
unit: '%'
scope: material
conditions:
grade: IMPHY Supra 50, annealed temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Mechanical properties table, Annealed row, Elongation column
- benchmark: hardness_vickers
label: Hardness, IMPHY Supra 50 annealed
value: 140
unit: HV
scope: material
conditions:
grade: IMPHY Supra 50, annealed temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Mechanical properties table, Annealed row, Hardness HV column
- benchmark: ultimate_tensile_strength
label: Tensile strength, IMPHY Supra 50 hard temper
value: 900
unit: MPa
scope: material
conditions:
grade: IMPHY Supra 50, hard temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 900 MPa (130 ksi)
status: ground
source: imphy-supra50
where: Mechanical properties table, Hard row, Tensile strength column
- benchmark: yield_strength
label: Yield strength, IMPHY Supra 50 hard temper
value: 1030
unit: MPa
scope: material
conditions:
grade: IMPHY Supra 50, hard temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025), printed as 1030 MPa (149 ksi)
status: ground
source: imphy-supra50
where: Mechanical properties table, Hard row, Yield strength column
- benchmark: elongation
label: Elongation, IMPHY Supra 50 hard temper
value: 3
unit: '%'
scope: material
conditions:
grade: IMPHY Supra 50, hard temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Mechanical properties table, Hard row, Elongation column
- benchmark: hardness_vickers
label: Hardness, IMPHY Supra 50 hard temper
value: 250
unit: HV
scope: material
conditions:
grade: IMPHY Supra 50, hard temper
method: Typical value printed in the Aperam Alloys Imphy datasheet (April 2025)
status: ground
source: imphy-supra50
where: Mechanical properties table, Hard row, Hardness HV column
- benchmark: saturation_induction
label: Saturation induction, Magnifer 50 (about 48 % Ni)
value: 1.55
unit: T
scope: material
conditions:
grade: VDM Magnifer 50, all three variants (RG, TG, T)
note: a general statement in the data sheet text, not tied to one variant or test
method: Value stated in the VDM Material Data Sheet No. 9002 (August 2002) text, with the claim that it is the highest saturation induction obtainable with a nickel-iron alloy
status: ground
source: vdm-magnifer50
where: Page 2, introduction paragraph (Magnifer 50 is a soft-magnetic nickel-iron alloy with about 48 percent Ni)
- benchmark: final_anneal_temperature
label: Final annealing temperature, Magnifer 50 RG and TG
value: 1050
value_high: 1250
bound: range
unit: °C
scope: material
conditions:
grade: Magnifer 50 RG and TG
time: 2 to 8 hours
atmosphere: dry hydrogen or cracked ammonia, dew point below -40 °C
method: Value printed in the VDM data sheet, Heat treatment section
status: ground
source: vdm-magnifer50
where: Page 4, Final annealing for obtaining optimum magnetic properties
- benchmark: density
label: Density, Nickel 211 (for comparison with Ni 212)
value: 8.72
unit: g/cm3
scope: material
conditions:
grade: Nickel 211, UNS N02211, Mn 4.5 to 5.50 %
temperature: room temperature
method: Value printed in the JLC Electromet datasheet (May 2016), Physical properties table
status: ground
source: jlc-ni211-212
where: Physical properties table, Ni 211 row
- benchmark: density
label: Density, Nickel 212
value: 8.86
unit: g/cm3
scope: material
conditions:
grade: Nickel 212, UNS N02212, Ni min 97.0 %, Mn 1.5 to 2.20 %
temperature: room temperature
method: Value printed in the JLC Electromet datasheet (May 2016), Physical properties table
status: ground
source: jlc-ni211-212
where: Physical properties table, Ni 212 row
- benchmark: thermal_conductivity
label: Thermal conductivity, Nickel 212
value: 44
unit: W/(m·K)
scope: material
conditions:
grade: Nickel 212
temperature: room temperature
unit_in_source: W/m K
method: Value printed in the JLC Electromet datasheet (May 2016)
status: ground
source: jlc-ni211-212
where: Physical properties table, Ni 212 row, Thermal Conductivity column
- benchmark: electrical_resistivity
label: Electrical resistivity, Nickel 212 at 20 degC
value: 11
unit: µΩ·cm
scope: material
conditions:
grade: Nickel 212
temperature: 20 °C
unit_in_source: µΩ-cm
method: Value printed in the JLC Electromet datasheet (May 2016)
status: ground
source: jlc-ni211-212
where: Physical properties table, Ni 212 row, Electrical Resistivity at 20 C column
- benchmark: cte
label: Linear expansion coefficient, Nickel 212, 20 to 95 degC
value: 12.9
unit: ppm/K
scope: material
conditions:
grade: Nickel 212
temperature_range: 20 to 95 °C
unit_in_source: 10-6/K
method: Value printed in the JLC Electromet datasheet (May 2016)
status: ground
source: jlc-ni211-212
where: Physical properties table, Ni 212 row, Linear Expansion Coeff. column
- benchmark: ultimate_tensile_strength
label: Tensile strength, Nickel 212 cold-drawn annealed wire
value: 450
value_high: 550
bound: range
unit: MPa
scope: material
conditions:
grade: Nickel 212, cold drawn annealed wire
basis: min and max printed as N/mm2, equal to MPa
method: Value printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 row
status: ground
source: jlc-ni211-212
where: Mechanical properties table, Ni 212 row, Tensile strength Min and Max
- benchmark: elongation
label: Elongation, Nickel 212 cold-drawn annealed wire
value: 20
value_high: 30
bound: range
unit: '%'
scope: material
conditions:
grade: Nickel 212, cold drawn annealed wire
gauge_length: 100 mm
method: Value printed in the JLC Electromet datasheet (May 2016), Mechanical Properties table, Ni 212 row
status: ground
source: jlc-ni211-212
where: Mechanical properties table, Ni 212 row, Elongation Min and Max at L0 = 100 mm
corrosion:
- environment: Cyclic damp heat (Magnifer 50 MH-BSo variant)
headline: No corrosion rate or test result was read for any grade here; the datasheet only says one variant resists damp heat better.
effect: VDM says the Magnifer 50 MH-BSo variant has increased corrosion resistance in a cyclic damp heat test and is used for stamped parts thicker than 0.5 mm. No measured value or test duration is printed in the text read.
rating: unknown
conditions:
material: Magnifer 50 MH-BSo
basis: qualitative statement in the datasheet
source: vdm-magnifer50
where: Page 2, Magnifer 50 MH-BSo paragraph
risks:
hazards: []
failure_risks:
- mode: Loss of magnetic properties after final annealing
trigger: Plastic deformation of Magnifer 50 parts after the final heat treatment
consequence: VDM says any plastic deformation after the final heat treatment causes a considerable loss of magnetic properties, so parts cannot be bent or pressed after final annealing.
severity: high
source: vdm-magnifer50
where: Page 4, Heat treatment section (final paragraph)
side_effects: []
handling:
- text: VDM says Magnifer 50 must be final-annealed in dry hydrogen or cracked ammonia (dew point below -40 °C), and that intermediate soft annealing at 800 to 1000 °C is best done in hydrogen, cracked ammonia or a clean inert gas. No supplier safety data sheet for any of these grades was opened.
source: vdm-magnifer50
where: Page 4, Heat treatment section
mitigations: []
uses:
- application: mechanisms
device: Soft-magnetic laminations, relay parts and stepping-motor parts (Magnifer 50 and Supra 50)
example: VDM lists rotor and stator laminations, relay parts, stepping motors and magnetic valves as typical applications of Magnifer 50. IMPHY lists relays, sensors and shielding for Supra 50.
source: vdm-magnifer50
where: Page 1, Typical applications list
- application: electronics-and-chips
device: Lead-in-wire fuses and lead wires in electrical components (Nickel 212)
example: JLC Electromet says Nickel 212 is used as fuses for lead-in-wire components in light bulbs and as lead wires in electrical components, and as electrodes in glow discharge lamps.
source: jlc-ni211-212
where: Applications column, Ni 212 entry
supply:
- subject: Nickel-iron soft-magnetic alloys and Nickel 212, producers and shares
abundance: No producer, country-share, critical-mineral or feedstock data was read for these grades in this run.
producers: []
critical_lists: []
recycling: Not read.
substitutes: []
source: imphy-supra50
where: Not read; the Aperam and JLC datasheets name the producer but give no market data.
documents:
- title: 'Aperam Alloys Imphy: IMPHY SUPRA 50 and SUPRA 50SP cold rolled strip datasheet'
type: datasheet
url: https://www.aperam.com/sites/default/files/documents/IMPHY%20S50%20IMPHY%20S50S%20APRIL%202025%20EN%201.pdf
year: 2025
- title: 'VDM Metals Material Data Sheet No. 9002: Magnifer 50 (copy hosted on alloy59.de)'
type: datasheet
url: https://alloy59.de/fileadmin/user_upload/Downloads/Data_Sheets/Data_Sheet_VDM_MAG_50.pdf
year: 2002
- title: 'JLC Electromet: Nickel-Manganese Alloys (Ni 211 and Ni 212) data sheet'
type: datasheet
url: https://www.jlcelectromet.com/downloads/16.data.sheet.Ni211.212.pdf
year: 2016
gaps:
- Only three manufacturer datasheets were read and fully checked in this run (IMPHY Supra 50, VDM Magnifer 50 and JLC Electromet Ni 211/212). The brief asked for 8 or more sources, so this file falls short; it is the three cited sources only.
- No sourced data for nickel-cobalt (Ni-Co). A search gave only a Goodfellow Ni50/Co50 overview with an unverified Curie temperature near 1000 °C, a density near 8.8 g/cm3 and resistivity 20 to 25 µΩ·cm, with references not shown. Those numbers were not read from a fetched page and are not entered.
- No sourced data for nickel-silicon (Ni-Si). The only silicon-bearing braze found was AWS BNi-5, which is a nickel-chromium-silicon filler, not a binary Ni-Si alloy. Its solidus, liquidus and composition were seen only in a search snippet and are not entered.
- No sourced data for nickel-vanadium (Ni-V). Melting point ranges and a Ni93/V7 figure came from supplier and reseller pages (American Elements, Stanford Advanced Materials, Goodfellow) that were not fetched, so none are entered.
- No sourced data for nickel-boron (Ni-B). The nickel boride pages (American Elements) show melting points and densities as N/A. The ASTM B607 coating standard gives electroless Ni-B hardness and says the coatings are microporous, but that standard was not fetched in this run, so no value is entered. The commercial brazing alloys BNi-7 (phosphorus-bearing) and BNi-9 (boron-bearing) are not binary alloys; their compositions were seen only in a MakeItFrom search summary and are not entered.
- No true 50/50 nickel-iron permalloy datasheet was read. The two nickel-iron grades here are about 48 percent Ni. ASTM A904 and SAE 50Ni-50Fe pages are paywalled; Goodfellow Fe50Ni50 powder and foil listings (density 8.39 g/cm3, Curie 530 °C) were not fetched as datasheets and are not entered.
- Magnifer 50 composition table (Mn, Si, C, Fe limits) and the grade-by-grade permeability and coercive-force table were partly cut in the text extract, so only the 48 percent nickel figure and the 1.55 T saturation statement are entered for Magnifer 50.
- Hardness scale for Nickel 212 and Magnifer 50 was not printed; only the IMPHY Supra 50 hardness values in HV are entered.
- No hazard data (GHS, SDS, workplace limits) was read for any grade in this file. The nickel.yaml profile carries the hazards for nickel metal, and the nickel-iron and Ni 212 hazards are not separately known.
- 'No supply data was read: producers, country shares and critical-mineral status for these grades are not recorded.'
- No corrosion test values were read. The Magnifer 50 MH-BSo variant is said to resist damp heat better, with no number.
- No space-environment data (outgassing, atomic oxygen, radiation, UV, flight results) was found for any grade here.
- Standard names in the datasheets (ASTM A753, DIN 17405, IEC 404, JIS C 2531 for IMPHY; DIN 41301 and DIN 17405 for Magnifer 50) are printed, but no designation is entered for a grade unless its source prints the code for that grade.
- Permeability and saturation values from the Magnifer 50 grade table (MF 13, MF 16, MG 16 and others) were not all entered, because the text extract did not give all columns reliably. The Supra 50 permeability value is the datasheet's typical value on rings, not a specification minimum.
- The canonical property names for hardness (HV), saturation induction, permeability and final annealing temperature are not in spores/property-canon.yaml. Those properties use short snake_case names, as the brief allows.
sources:
vdm-magnifer50:
title: 'VDM Metals Material Data Sheet No. 9002: Magnifer 50 soft-magnetic nickel-iron alloy'
id: VDM Material Data Sheet No. 9002, August 2002 edition
url: https://alloy59.de/fileadmin/user_upload/Downloads/Data_Sheets/Data_Sheet_VDM_MAG_50.pdf
year: 2002
kind: datasheet
license: VDM datasheet, linked not reproduced
imphy-supra50:
title: 'Aperam Alloys Imphy: IMPHY SUPRA 50 and SUPRA 50SP cold rolled strip datasheet'
id: IMPHY S50 / S50S, April 2025
url: https://www.aperam.com/sites/default/files/documents/IMPHY%20S50%20IMPHY%20S50S%20APRIL%202025%20EN%201.pdf
year: 2025
kind: datasheet
license: Aperam datasheet, linked not reproduced
jlc-ni211-212:
title: 'JLC Electromet: Nickel-Manganese Alloys, Ni 211 and Ni 212 wire, strip and ribbon data sheet'
id: JLC Electromet data sheet, May 2016
url: https://www.jlcelectromet.com/downloads/16.data.sheet.Ni211.212.pdf
year: 2016
kind: datasheet
license: Supplier datasheet, linked not reproduced
license: CC-BY-4.0
updated: '2026-10-26'
review:
status: draft
method: assistant
checked_values: 27
unreachable: 0
caveats: 5
note: Written by an AI assistant on 2026-10-26. Values were read in text extracted from the three datasheets (pdftotext). Nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron have no sourced values; they are listed in gaps. Only three sources, so the brief's 8-source minimum was not met. The Magnifer 50 grade table is partly unreadable in the extract. No hazard, supply or corrosion test data was read.
story:
risk_groups:
- title: For people
level: 1
verdict: No hazard data read for these grades
lead: No safety data sheet or hazard statement was read for the nickel-iron or Ni 212 grades in this run. The nickel metal hazards are in nickel.yaml, not repeated here.
points:
- label: Handling
line: VDM gives annealing atmosphere rules and no health statement for Magnifer 50.
- title: If it fails
level: 2
verdict: Bending after final anneal destroys soft magnetism
lead: The main failure route read in these datasheets is mechanical, not chemical.
points:
- label: Plastic deformation
line: VDM says any plastic deformation after final heat treatment causes a considerable loss of magnetic properties, so parts cannot be worked after final annealing.
- label: Wrong anneal atmosphere
line: VDM says final annealing must be done in dry hydrogen or cracked ammonia at a dew point below -40 °C.
why: 'These are nickel alloys in two families. The nickel-iron soft-magnetic alloys (VDM Magnifer 50 and IMPHY Supra 50, both about 48 percent nickel) are chosen for the highest saturation induction a nickel-iron alloy can reach: 1.55 T for Magnifer 50 and 1.50 T for Supra 50 at 10 Oe. Their Curie temperature is 450 °C. The nickel-manganese grade Nickel 212 (UNS N02212) is pure nickel with a small manganese addition, at least 97.0 percent nickel and 1.5 to 2.20 percent manganese, and is made for wire and strip. Pure nickel is covered in nickel.yaml, and nickel-base superalloys are in the other profiles in this family. Nickel-cobalt, nickel-silicon, nickel-vanadium and nickel-boron are named in the brief but have no sourced values here.'
uses:
- where: Relays, stepping motors and laminations
line: VDM lists rotor and stator laminations, relay parts, stepping motors, chokes and magnetic valves as typical uses of Magnifer 50. IMPHY lists relays, sensors and shielding for Supra 50.
- where: Lead wires and fuses
line: JLC Electromet says Nickel 212 is used as fuses for lead-in-wire components in light bulbs, as lead wires in electrical components, and as electrodes in glow discharge lamps.
can_do:
- label: Magnetic strength
value: 1.55 T saturation
benchmark: saturation_induction
line: Magnifer 50 has a saturation induction of 1.55 T. Supra 50 reaches 1.50 T at 10 Oe and has a maximum permeability of 200000 in direct current.
- label: Heat
value: Curie point 450 °C
benchmark: curie_temperature
line: Supra 50 loses its magnetism above 450 °C, and melts at 1425 °C.
- label: Density
value: 8.2 g/cm3 (Supra 50) and 8.86 g/cm3 (Ni 212)
benchmark: density
line: Supra 50 has a density of 8.2 g/cm3. Nickel 212 has 8.86 g/cm3, against 8.72 g/cm3 for Nickel 211.
- label: Strength annealed
value: 500 MPa tensile (Supra 50)
benchmark: ultimate_tensile_strength
line: Annealed Supra 50 has tensile strength 500 MPa, yield 280 MPa and elongation 35 percent. Hard temper gives 900 MPa tensile and 1030 MPa yield, with only 3 percent elongation.
- label: Nickel 212 wire
value: 450 to 550 MPa tensile
benchmark: ultimate_tensile_strength
line: Cold-drawn annealed Nickel 212 wire has tensile strength 450 to 550 MPa and elongation 20 to 30 percent at a 100 mm gauge length.
compare: The sources give no direct comparison between these grades and other nickel alloys. Among the two families, Supra 50 is the softer and heavier of the two nickel-iron grades (8.2 g/cm3 against no density printed for Magnifer 50), while Nickel 212 is the denser and more conductive nickel product, at 8.86 g/cm3 and 44 W/(m·K). Nothing here ranks the grades for any space use.
compare_rows:
- label: Density
benchmark: density
- label: Thermal conductivity
benchmark: thermal_conductivity
- label: Thermal expansion
benchmark: cte
handling:
- Final-anneal nickel-iron parts in dry hydrogen or cracked ammonia with a dew point below -40 °C, as VDM says.
- Do not deform Magnifer 50 parts after the final heat treatment; plastic strain causes a considerable loss of magnetic properties.
- Read the producer safety data sheet for the nickel product before handling dust or powder; none was read for these grades.
good_for:
- 'High saturation induction in a strip alloy: 1.55 T for Magnifer 50 and 1.50 T for Supra 50.'
- Lightweight, electrically conductive nickel wire for lead-in and lead components, with 11 µΩ·cm resistivity for Nickel 212.
watch_out:
- Almost no sourced data for nickel-cobalt, nickel-silicon, nickel-vanadium or nickel-boron in this file.
- Only three datasheets and about 48 percent nickel grades; no true 50/50 permalloy datasheet was read.
- No corrosion test values, hazard data or space-environment data for any grade here.
verdict: The nickel-iron soft-magnetic alloys (about 48 percent Ni) have sourced magnetic and mechanical values from two manufacturers, and Nickel 212 wire has sourced density, conductivity and tensile values from one. The four named binary systems (Ni-Co, Ni-Si, Ni-V, Ni-B) are unsourced here, and no space-environment or hazard data was found.
recipe:
line: Nickel-iron soft-magnetic alloys contain about 48 percent Ni with iron as the balance (IMPHY and VDM). Magnifer 50 is final-annealed at 1050 to 1250 °C in dry hydrogen or cracked ammonia (VDM). Nickel 212 is at least 97.0 percent Ni with 1.5 to 2.20 percent Mn, and its other elements are maximum limits only (JLC). Process steps beyond heat treatment are not in these sources.
parts:
- name: Nickel
symbol: Ni
share: about 48 percent (nickel-iron grades) or at least 97.0 percent (Ni 212)
role: Base metal of the nickel-iron alloy, and the main element of Nickel 212
- name: Iron
symbol: Fe
share: balance (nickel-iron grades); low residual in Ni 212
role: Balance element in the soft-magnetic nickel-iron alloys
- name: Manganese
symbol: Mn
share: 1.5 to 2.20 percent (Ni 212)
role: 'Small addition to raise the strength of Nickel 212 (JLC: improves strength)'
References
Every number above carries a reference number. Click one to see the source and where in it the value comes from.
| # | Source | Type | Year | Used for |
|---|---|---|---|---|
| VDM Metals Material Data Sheet No. 9002: Magnifer 50 soft-magnetic nickel-iron alloy | datasheet | 2002 | 6 values | |
| Aperam Alloys Imphy: IMPHY SUPRA 50 and SUPRA 50SP cold rolled strip datasheet | datasheet | 2025 | 18 values | |
| JLC Electromet: Nickel-Manganese Alloys, Ni 211 and Ni 212 wire, strip and ribbon data sheet | datasheet | 2016 | 9 values |