Rogers RO4350B hydrocarbon-ceramic laminate RO4350B

Glass-reinforced hydrocarbon and ceramic thermoset laminate, non-PTFE. The exact composition is not printed in the datasheet.

Also known as RO4350B

Rogers RO4350B is a glass-reinforced hydrocarbon and ceramic circuit laminate with no PTFE.

8 sources · Updated 2026-11-02 · CC BY 4.0

Evidence level

2 of 5

Lab-measured

Dielectric constant

3.48 at 10 GHz

Low loss

0.0037 at 10 GHz

Temperature stability

50 ppm/°C

Heat

Above 280 °C

Expansion

10, 12 and 32 ppm/°C

Recipe, share of the weight

  • not statedHydrocarbon and ceramic thermoset resin
  • not statedWoven glass fabric (1080 or 1674 style)
  • not statedElectrodeposited copper foil

Best for

RF and microwave antennas, power amplifiers and LNBs that need a stable dielectric constant and FR-4 style processing

Weakest at

Dielectric constant drifts 50 ppm/°C with temperature, and Rogers notes that prolonged oxidative exposure can change dielectric properties. No space-qualification data were found.

Risk at a glance

  • People None found. Dust and fume hazards; no GHS class on record
  • If it fails Moderate. Dielectric constant drift over temperature
  • Corrosion No data. No corrosion data recorded

Quick facts: RO4350B

Key properties of RO4350B
PropertyValueBasis
Density1.86 gm/cm31 sourced value
Tensile strength130 to 203 MPa2 sourced values across conditions
Young's modulus14.2 to 16.8 GPa2 sourced values across conditions
Thermal conductivity0.69 W/m/°K1 sourced value
Thermal expansion (CTE)10 to 32 ppm/K3 sourced values across conditions

What is the density of Rogers RO4350B hydrocarbon-ceramic laminate?

Rogers RO4350B hydrocarbon-ceramic laminate has a density of 1.86 gm/cm3. The source and test conditions are listed in the properties table on this page.

What is the thermal conductivity of Rogers RO4350B hydrocarbon-ceramic laminate?

Rogers RO4350B hydrocarbon-ceramic laminate has a thermal conductivity of 0.69 W/m/°K. The source and test conditions are listed in the properties table on this page.

What is the coefficient of thermal expansion of Rogers RO4350B hydrocarbon-ceramic laminate?

Rogers RO4350B hydrocarbon-ceramic laminate has a coefficient of thermal expansion of 10 to 32 ppm/K. The range covers 3 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the tensile strength of Rogers RO4350B hydrocarbon-ceramic laminate?

Rogers RO4350B hydrocarbon-ceramic laminate has a tensile strength of 130 to 203 MPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is the Young's modulus of Rogers RO4350B hydrocarbon-ceramic laminate?

Rogers RO4350B hydrocarbon-ceramic laminate has a Young's modulus of 14.2 to 16.8 GPa. The range covers 2 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.

What is Rogers RO4350B hydrocarbon-ceramic laminate used for?

Uses recorded in the sources include Low-noise block converters (LNBs) for direct broadcast satellites; Cellular base station antennas and power amplifiers; Automotive radar and sensors.

Why it exists

Rogers RO4350B is a glass-reinforced hydrocarbon and ceramic circuit laminate with no PTFE. It is made for RF and microwave circuits that need a stable dielectric constant at GHz frequencies, and it can be fabricated with standard FR-4 processes. Rogers' 2016 datasheet gives a process dielectric constant of 3.48 plus or minus 0.05 at 10 GHz and 23 °C, and a dissipation factor of 0.0037 at 10 GHz. Rogers describes RO4350B as a drop-in replacement for RO4003C with flame retardance added.

Where it's used

LNBs and base stations

Rogers lists low-noise block converters for direct broadcast satellites, cellular base station antennas and power amplifiers as typical applications for RO4350B.

Automotive radar and RFID

The 2016 datasheet also lists automotive radar and sensors, and RF identification tags, among the typical applications.

Recipe

Glass-reinforced hydrocarbon and ceramic thermoset laminate, non-PTFE. The exact composition is not printed in the datasheet.

Rogers does not print the full recipe for RO4350B. The datasheets describe a glass-reinforced hydrocarbon and ceramic thermoset with no PTFE, clad with electrodeposited copper foil, and give no percentages.

What RO4350B is made of
IngredientShare of the weightWhat it does
Hydrocarbon and ceramic thermoset resin not stated The dielectric matrix. Rogers describes it only as a glass-reinforced hydrocarbon and ceramic system with no PTFE.
Woven glass fabric (1080 or 1674 style) not stated The reinforcement that gives the laminate its rigidity and the low Z-axis expansion Rogers describes.
Electrodeposited copper foil not stated The conductor cladding, offered in several foil weights from half an ounce to two ounces.

Weight shares are as printed in the sources.

What it can do

Dielectric constant

3.48 at 10 GHz

measured

At 10 GHz and 23 °C, Rogers prints a process dielectric constant of 3.48 plus or minus 0.05. Its design value, averaged over several lots and taken from 8 to 40 GHz, is 3.66.

Low loss

0.0037 at 10 GHz

measured

The dissipation factor is 0.0037 at 10 GHz and 23 °C, and 0.0031 at 2.5 GHz and 23 °C, per the 2016 typical values table.

Temperature stability

50 ppm/°C

measured

The dielectric constant changes by 50 ppm/°C in the Z direction over -50 °C to 150 °C.

Heat

Above 280 °C

measured

The glass transition is printed as greater than 280 °C by TMA, and the decomposition temperature is 390 °C by TGA (ASTM D3850).

Expansion

10, 12 and 32 ppm/°C

measured

Expansion is 10 ppm/°C in X, 12 ppm/°C in Y and 32 ppm/°C in Z, all measured from -55 °C to 288 °C (IPC-TM-650 2.4.41).

How it compares

Against RO4003C, the other grade in the same Rogers datasheet, RO4350B prints a higher dielectric constant at 10 GHz (3.48 against 3.38) and a higher dissipation factor (0.0037 against 0.0027). RO4350B adds a UL 94 V-0 flame rating, which RO4003C does not carry. No numeric comparison with standard FR-4 is printed in the datasheets read, so the only FR-4 comparison here is that both grades use FR-4 style processing.

The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details.

Benchmarks
MeasurementRO4350B
Thermal behavior and safety
Thermal coefficient of dielectric constant, RO4350BIPC-TM-650 2.5.5.5, as printed50 ppm/°C
Thermal conductivity, RO4350B, 80 °CASTM C518, as printed0.69 W/m/°K
Physical and electrical
Density, RO4350BASTM D792, as printed1.86 gm/cm³
Temperature behavior
Glass transition temperature, RO4350B (printed greater than)TMA, IPC-TM-650 2.4.24 condition A, as printed280 °C
Decomposition temperature (Td), RO4350BTGA, ASTM D3850, as printed390 °C
Other measurements
Dielectric constant (process value), RO4350B, 10 GHz3.48 -1
Dielectric constant (design value), RO4350B3.66 -2
Dielectric constant (process value), RO4350B 4 mil laminate3.33 -3
Dissipation factor, RO4350B, 10 GHzIPC-TM-650 2.5.5.5, as printed0.0037 -4
Dissipation factor, RO4350B, 2.5 GHzIPC-TM-650 2.5.5.5, as printed0.0031 -5
Coefficient of thermal expansion, X direction, RO4350BIPC-TM-650 2.4.41, as printed10 ppm/°C
Coefficient of thermal expansion, Y direction, RO4350BIPC-TM-650 2.4.41, as printed12 ppm/°C
Coefficient of thermal expansion, Z direction, RO4350BIPC-TM-650 2.4.41, as printed32 ppm/°C
Moisture absorption, RO4350B, 48 h immersionASTM D570, as printed0.06 %6
Flexural strength, RO4350B255 MPa7
Tensile strength, X direction, RO4350B203 MPa8
Tensile strength, Y direction, RO4350B130 MPa9
Tensile modulus, X direction, RO4350B16770 MPa10
Tensile modulus, Y direction, RO4350B14150 MPa11
Dimensional stability, RO4350B, after etchIPC-TM-650 2.4.39A, as printed0.5 mm/m12
Electrical strength, RO4350B, 0.51 mm31.2 kV/mm13
Copper peel strength, RO4350B, after solder float, 1 oz foilIPC-TM-650 2.4.8, as printed0.88 N/mm14

Why choose it, and why not

Good for

  • Microstrip and stripline RF circuits at GHz frequencies: Rogers prints 3.48 plus or minus 0.05 at 10 GHz and a dissipation factor of 0.0037 at the same frequency.
  • Board makers that want FR-4 processing for RF parts: Rogers says no sodium etch is needed for via preparation.

Watch out for

  • The dielectric constant drifts 50 ppm/°C with temperature, so temperature-sensitive designs must use that coefficient.
  • Process and design values differ: 3.48 is the process value at 10 GHz, and 3.66 is the design value over 8 to 40 GHz.
  • Prolonged exposure to oxidative conditions can change dielectric properties, and Rogers asks users to test each design over the product life.
  • Measured dielectric constant depends on the test method. The 2022 note says a clamped stripline method can lower the value because of air gaps.

RO4350B is a practical RF laminate for GHz circuits built with FR-4 processes. The sources here give manufacturer typical values only, and no space or radiation data were found, so flight use needs its own test data.

Technical details

For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.

Other names and standards

The same grade under other systems, as datasheets and standards print them. Each code was checked against the page it comes from.

Other names and standards
SystemCodes
Trade nameRO4350B

Notes

The method, full conditions and any caveat for the numbered rows above.

Notes for the numbered rows
#MeasurementMethodConditionsCaveat
1Dielectric constant (process value), RO4350B, 10 GHzIPC-TM-650 2.5.5.5, clamped stripline, as printed in the typical values tablefrequency 10 GHztemperature 23 °Cdirection Ztolerance ±0.05 as printedthickness standard thicknesses (the 4 mil laminate has its own value)—
2Dielectric constant (design value), RO4350BClamped stripline differential phase length method, as printed. The 2022 TICER datasheet prints the same 3.66 design value by the FSR method at 23 °C.frequency 8 to 40 GHzdirection Zbasis average of several tested lots on the most common thicknesses (Rogers note 1)—
3Dielectric constant (process value), RO4350B 4 mil laminateProcess value stated in the footnote of the 2022 datasheet; the footnote says the product conforms to IPC-4103A/240thickness 0.004 in (0.101 mm)tolerance ±0.05 as printedbasis process value for the 4 mil product, Rogers note 2—
4Dissipation factor, RO4350B, 10 GHz—frequency 10 GHztemperature 23 °Cdirection Z—
5Dissipation factor, RO4350B, 2.5 GHz—frequency 2.5 GHztemperature 23 °Cdirection Z—
6Moisture absorption, RO4350B, 48 h immersion—time 48 hours immersionsample 0.060 intemperature 50 °C—
7Flexural strength, RO4350BIPC-TM-650 2.4.4, as printed; the datasheet prints 37 kpsi beside ittest IPC-TM-650 2.4.4, as printeddirection not printed—
8Tensile strength, X direction, RO4350BASTM D638, as printed; the datasheet prints 29.5 kpsi beside itdirection Xtemperature room temperature (RT)—
9Tensile strength, Y direction, RO4350BASTM D638, as printed; the datasheet prints 18.9 kpsi beside itdirection Ytemperature room temperature (RT)—
10Tensile modulus, X direction, RO4350BASTM D638, as printed; the datasheet prints 16,767 MPa (2,432 kpsi)direction Xtemperature room temperature (RT)—
11Tensile modulus, Y direction, RO4350BASTM D638, as printed; the datasheet prints 14,153 MPa (2,053 kpsi)direction Ytemperature room temperature (RT)—
12Dimensional stability, RO4350B, after etch—bound printed as less than 0.5 mm/mdirection X and Yprocess after etch, +E2/150 °C—
13Electrical strength, RO4350B, 0.51 mmIPC-TM-650 2.5.6.2, as printed; the datasheet prints 780 V/mil beside itdirection Zthickness 0.51 mm (0.020 in)—
14Copper peel strength, RO4350B, after solder float, 1 oz foil—foil 1 oz (35 µm) electrodeposited coppercondition after solder floatprinted pli 5.0 pli printed beside the value—

Corrosion and compatibility

What happens when it meets other materials and environments.

Corrosion and compatibility
EnvironmentConcernWhat happens
Prolonged exposure in an oxidative environment, faster at higher temperature not rated Rogers says oxidation over long exposure can change the dielectric properties of hydrocarbon laminates such as RO4350B.1
Water immersion (humid service) not rated RO4350B absorbs 0.06 % moisture after 48 hours of immersion, per ASTM D570.2
Elevated temperature not rated RO4350B has a glass transition printed as greater than 280 °C and a decomposition temperature of 390 °C by TGA.3
Corrosion details
#EnvironmentDetailsTest conditions
1 Prolonged exposure in an oxidative environment, faster at higher temperature The rate of change rises at higher temperature and depends on the circuit design. Rogers calls oxidation problems extremely rare, but asks customers to evaluate each material and design combination over the life of the product. basis general note from Rogers; no test figure printed
2 Water immersion (humid service) The 2016 datasheet prints 0.06 % for RO4350B. The 2005 revision printed 0.04 % for the same grade, and the two are reported side by side in the gaps. time 48 hours immersionsample 0.060 intemperature 50 °C
3 Elevated temperature Rogers prints Tg above 280 °C by TMA and Td of 390 °C by TGA (ASTM D3850). Dimensional stability after etch and 150 °C is less than 0.5 mm/m, and the CTE is 10, 12 and 32 ppm/°C in X, Y and Z from -55 °C to 288 °C. basis typical values printed by the manufacturer; no ageing test is printed

Risks and side effects

Hazards to people, what happens when a cell overheats, and how the material is handled and stored.

For people

The series product safety sheet names machining dust and fumes from overheating as the hazards, and gives no GHS classification for the laminate.

Hazard data
The English safety sheet covers the RO4000 series as one product, not RO4350B alone. Get the grade's own safety data sheet before machining the board.
Copper cladding
PubChem lists copper metal as very toxic to aquatic life, with the signal word Warning. The sheet says to keep the laminate out of sewers, surface water and soil.
Flame rating
Standard RO4350B is rated UL 94 V-0. That is a flame rating for the laminate, not a hazard classification.

In service

Rogers describes the risks in service in terms of temperature and oxidation.

Oxidation over life
Rogers says prolonged oxidative exposure can change the dielectric properties of hydrocarbon laminates, and the rate rises with temperature.
Temperature
The dielectric constant changes by 50 ppm/°C across the range -50 °C to 150 °C.

Test details
The original wording and numbers from the sources, for readers who want them.

Failure risks

Failure risks
FailureTrigger and consequence
Dielectric constant drift over temperaturemoderate severityOperation across the temperature range Rogers specifies, -50 °C to 150 °CThe dielectric constant changes by 50 ppm/°C in the Z direction (typical), so the design value shifts with temperature.
Dielectric change from long oxidative exposuremoderate severityProlonged exposure in an oxidative environment, faster at higher temperatureRogers says the dielectric properties of hydrocarbon-based laminates can change, and asks users to evaluate each material and design over the product life.

Handling and storage

  • Rogers says RO4000 laminates use standard epoxy/glass (FR-4) processes and need no sodium etch for via preparation. The laminate is rigid and thermoset, and runs in automated handling and scrubbing equipment used for copper surface preparation.
  • Standard RO4350B is rated UL 94 V-0 (printed as V-0 in the 2016 datasheet and as 94V-O in the 2005 datasheet). The LoPro variant does not share this UL designation, per Rogers note 2.
  • Storage: fully clad laminates should be stored at room temperature, with first-in-first-out stock and lot numbers tracked through processing.
  • Humidity: at room temperature the dielectric is inert to high humidity, but copper cladding can oxidise, and a standard micro-etch removes that oxide before processing.
  • Drilling: standard geometry drills are preferred over undercut styles, and drilling causes an accelerated wear rate of drills, so hit counts should be based on inspection of the plated holes.
  • Routing: copper should be etched away from the routing path to prevent burring, and carbide multi-fluted spiral tools or diamond cut router bits are used, per the processing guideline.
  • Dust and fumes: the product safety sheet says machining may create dust, that processing above the decomposition temperature may release toxic fumes, and it recommends safety glasses with side-shields in industrial operations.

Supply and geography

How common the raw materials are and where they come from.

Copper (electrodeposited foil cladding)

Mine production 2025e, thousand metric tons of copper content (USGS): Chile 5,300; Congo (Kinshasa) 3,200; Peru 2,700; China 1,800; United States 1,000; world total 23,000.

Critical mineral lists
US: listed
Recycling
USGS: an estimated 160,000 tons of copper was recovered from old scrap in the United States in 2025, and 760,000 tons from new scrap.
Substitutes
USGS: aluminum substitutes for copper in electrical equipment and power cable, and optical fiber substitutes for copper in telecommunications.

Updated