Water H2O
H2O · CAS 7732-18-5
Liquid water has a density of 999.79 kg/m3 at 0.028556 °C in the NIST saturation table, and it holds 4.2198 J/(g*K) of heat capacity at the same point.
Evidence level
2 of 5
Lab-measured
- 0Predicted only. No one has made it, or no measurement exists.
- 1Calculated. Only calculated or predicted values from sources.
- 2Lab-measured. Measured properties with their conditions stated.
- 3Space-relevant tests. Measured in conditions relevant to space, such as vacuum or atomic oxygen.
- 4Ground-qualified. Qualified for an application on the ground.
- 5Flown or field-proven. Flight or field results exist.
Radiation shielding
130 days
Heat capacity
4.2198 J/(g*K)
Liquid range at 1 atm
0 °C to 99.974 °C
Recipe, share of the weight
- H not statedHydrogen
- O not statedOxygen
Best for
Hydrogen-rich shielding for crew areas that already hold potable water (NASA Langley analysis, 2013; ISS potable water practice, ICES 2023)
Weakest at
Freezing: water expands on freezing (PubChem), and stored water needs a biocide to stay free of microbes and biofilm (NASA ICES 2025)
Risk at a glance
- People None found. Not classified hazardous
- If it fails Moderate. Freezing of stored water
- Corrosion Moderate. Stored potable water needs a biocide to control microbes, biofilm and microbially influenced corrosion.
Quick facts: H2O
| Property | Value | Basis |
|---|---|---|
| Density | 0.92 to 1 g/cm³ | 4 sourced values across conditions |
| Melting point | 0 °C | 1 sourced value |
| Specific heat | 4,220 J/(kg·K) | 1 sourced value |
What is the density of Water (H2O)?
Water (H2O) has a density of 0.92 to 1 g/cm³. The range covers 4 sourced values across the tempers, forms and test conditions the sources report; room-temperature values are used where a source states a temperature.
What is the melting point of Water (H2O)?
Water (H2O) has a melting point of 0 °C. The source and test conditions are listed in the properties table on this page.
What is Water (H2O) used for?
Uses recorded in the sources include Deep-space crew shielding (analysis only); Deep-space vehicle with permanent on-board water storage (modelling thesis); International Space Station potable water system (drinking, hygiene and technical water).
Why it exists
Water is a hydrogen-rich material that the International Space Station already stores as potable water (ICES 2023). A 2013 NASA Langley analysis found that a single heavy-lift launch of water could protect astronauts for a 130-day deep-space mission under its assumptions, the same as polyethylene. A 2018 Cal Poly thesis concludes that permanent on-board water storage adds protection against galactic cosmic rays and solar particle events; its abstract gives no numbers. The shielding figures are analysis results, not flight measurements.
Where it's used
Deep-space crew shielding (analysis)
A NASA Langley analysis found that a single heavy-lift launch of water could protect astronauts for a 130-day mission before the 150 mSv design basis was exceeded, under the 1977 galactic cosmic ray environment.
Potable water on the International Space Station
Iodine and silver biocides have been used on the International Space Station to control microbes in potable water. A 2023 ICES paper compares them for drinking, hygiene, technical, oxygen-generation and extravehicular activity water.
Recipe
H2O
Water is H2O: one oxygen atom bonded covalently to two hydrogen atoms (PubChem, CAS 7732-18-5). Its molecular weight is 18.015 g/mol (PubChem). Water is not mined; it is the liquid that the shield and the potable water system store.
| Ingredient | Share of the weight | What it does |
|---|---|---|
| Hydrogen H | not stated | Two hydrogen atoms per molecule. Hydrogen makes up 11.19% of the mass of water (calculated; see properties). NIST prints the standard atomic weight of hydrogen as an interval, so no single value is given here. |
| Oxygen O | not stated | One oxygen atom per molecule; the rest of the mass of water. NIST prints the standard atomic weight of oxygen as an interval, so no single value is given here. |
Weight shares are as printed in the sources.
What it can do
Radiation shielding
130 days
worked out from the formula
A single heavy-lift launch of water can protect astronauts for a 130-day mission under the 1977 galactic cosmic ray environment, before the 150 mSv design basis is exceeded (NASA Langley analysis, 2013).
Heat capacity
4.2198 J/(g*K)
measured
Saturated liquid water has an isobaric heat capacity of 4.2198 J/(g*K) at 0.028556 °C, per the NIST saturation table.
Liquid range at 1 atm
0 °C to 99.974 °C
Liquid water runs from its melting point of 0 °C to its boiling point of 99.974 °C, as printed by PubChem; the record gives the boiling point without its pressure, and the same record gives 212 °F at 760 mmHg.
How it compares
Per launch, the 2013 NASA Langley analysis finds that water and polyethylene protect astronauts for the same 130-day mission under its assumptions. The same abstract gives 160 days for liquid hydrogen and says that liquid hydrogen is not the best shield per unit mass compared with polyethylene for missions longer than 225 days. These are analysis results for the 1977 galactic cosmic ray environment, not measurements. The NIST table gives only the photon (X-ray and gamma) attenuation of water, so it does not show how water compares for galactic cosmic rays.
The same measurements for each material, so you can compare them. Each row names the key condition under the value; the full conditions and methods are in the numbered notes under Technical details.
| Measurement | H2O |
|---|---|
| Thermal behavior and safety | |
| Melting point of ice and water | 0 °C5 |
| Isobaric heat capacity of saturated liquid water near 0 °C | 4.22 J/(g*K)10 |
| Vapor pressure of water at 273.16 K | 611.7 Pa13 |
| Physical and electrical | |
| Density of saturated liquid water near 0 °C | 999.8 kg/m31 |
| Density of liquid water at 0 °C/4 °C, PubChem | 0.9999 g/cm³2 |
| Density of liquid water at 25 °C, PubChem | 0.995 g/cm³3 |
| Density of ice at 0 °C | 0.917 g/cm³4 |
| Temperature of maximum density of liquid waterValue printed in the PubChem record | 3.98 °C15 |
| Temperature behavior | |
| Critical temperature, NIST averageValue printed in the NIST phase change data | 647 K |
| Critical temperature, PubChemValue printed in the PubChem record | 374.2 °C8 |
| Other measurements | |
| Boiling point, PubChem | 99.97 °C6 |
| Boiling point, NIST averageValue printed in the NIST phase change data | 373.2 K7 |
| Critical pressure, NISTValue printed in the NIST phase change data | 220.6 bar |
| Critical pressure, PubChemValue printed in the PubChem record | 218 atm9 |
| Dynamic viscosity of saturated liquid water near 0 °C | 1790 uPa*s11 |
| Surface tension of water at 25 °C | 71.97 dyne/cm12 |
| Refractive index of water | 1.333 -14 |
| Hydrogen share of the mass of water | 11.19 %16 |
| Protection time from a single heavy-lift launch of water | 130 days17 |
Why choose it, and why not
Good for
- Hydrogen-rich shielding in crew areas where potable water is already stored (NASA Langley, 2013; ICES 2023).
- A well-characterised heat capacity: 4.2198 J/(g*K) for saturated liquid near 0 °C (NIST).
Watch out for
- Freezing: water expands when it freezes (PubChem), and no source read here tests what that does to a tank.
- Biological growth: stored water needs a biocide (NASA ICES 2025).
- The 130-day protection figure is a 2013 analysis under stated assumptions, not a flight test.
Water is a practical hydrogen-rich shield for crew areas that already hold potable water. Its shielding value rests on a 2013 analysis, not on a flight test, and it must be kept from freezing and from microbes.
Used in space products
Space hardware whose maker names H2O, with the part it is used for.
| Product | Where it is used |
|---|---|
| Destiny laboratory module (ISS)NASA / Boeing | Low Temperature Loop (LTL), water loop; Moderate Temperature Loop (MTL), water loop |
Technical details
For scientists and researchers. Everything above comes from the record below: every number with its method, its conditions and its source.
Notes
The method, full conditions and any caveat for the numbered rows above.
| # | Measurement | Method | Conditions | Caveat |
|---|---|---|---|---|
| 1 | Density of saturated liquid water near 0 °C | Value copied from the NIST Chemistry WebBook saturation table | state saturated liquidtemperature 0.028556 °C (first printed row of the saturation table)pressure 0.00061248 MPa (saturation pressure as printed) | — |
| 2 | Density of liquid water at 0 °C/4 °C, PubChem | Experimental density value printed in the PubChem record | state liquidbasis printed as 0.999868 at 0 °C/4 °C (liquid) | — |
| 3 | Density of liquid water at 25 °C, PubChem | Experimental density value printed in the PubChem record | state liquidtemperature 25 °C | The 25 °C figure was not checked against a second source. It is lower than the NIST value near 0 °C, and the two temperatures differ, so they are not compared directly. |
| 4 | Density of ice at 0 °C | Experimental density value printed in the PubChem record | phase icetemperature 0 °C | — |
| 5 | Melting point of ice and water | Value printed in the PubChem experimental melting point entry | pressure not stated in the source | — |
| 6 | Boiling point, PubChem | Value printed in the PubChem experimental boiling point entry | pressure not stated for this value; the same PubChem record gives 212 °F at 760 mmHg | — |
| 7 | Boiling point, NIST average | — | pressure not stated on the pageuncertainty ±0.04 K, average of 7 values | NIST gives 373.17 K, which is about 0.05 °C above the PubChem value of 99.974 °C. Both are kept as printed. |
| 8 | Critical temperature, PubChem | — | basis printed in the PubChem safety and hazard properties section | The PubChem value of 374.2 °C differs from the NIST value of 647 K (about 373.9 °C). Both are kept as printed. |
| 9 | Critical pressure, PubChem | — | basis printed in the PubChem safety and hazard properties section | The PubChem value of 218 atm differs from the NIST value of 220.64 bar (about 217.8 atm). Both are kept as printed. |
| 10 | Isobaric heat capacity of saturated liquid water near 0 °C | Value copied from the NIST saturation table, Cp column | state saturated liquidtemperature 0.028556 °C (first printed row)pressure saturation | — |
| 11 | Dynamic viscosity of saturated liquid water near 0 °C | Value copied from the NIST saturation table, Viscosity column | state saturated liquidtemperature 0.028556 °C (first printed row) | Snake-case name; this property is not in spores/property-canon.yaml. |
| 12 | Surface tension of water at 25 °C | Value printed in the PubChem experimental surface tension entry | temperature 25 °C | — |
| 13 | Vapor pressure of water at 273.16 K | Value printed in the PubChem experimental vapor pressure entry | temperature 273.16 K | Snake-case name; this property is not in spores/property-canon.yaml. |
| 14 | Refractive index of water | Value printed in the PubChem refractive index entry | temperature not stated in the sourcewavelength not stated in the source | — |
| 15 | Temperature of maximum density of liquid water | — | basis printed as the temperature of maximum density in the PubChem density entry | Snake-case name; this property is not in spores/property-canon.yaml. |
| 16 | Hydrogen share of the mass of water | Calculated by Space Mushroom: 2 x 1.008 / 18.015 = 11.19%. The NIST atomic weight of hydrogen is printed as the interval [1.007 84, 1.008 11], which gives the same 11.19% to two decimals. | basis 2 hydrogen atoms in H2O divided by the molecular weight 18.015 g/mol, with hydrogen taken as 1.008 g/mol | Snake-case name; this property is not in spores/property-canon.yaml. |
| 17 | Protection time from a single heavy-lift launch of water | Analysis result stated in the paper abstract; not a measurement | environment 1977 galactic cosmic ray environmentexposure limit 150 mSv design basislaunch single heavy-lift launch of pure shielding mass, under the paper's assumptions | Snake-case name; this property is not in spores/property-canon.yaml. The same abstract gives 160 days for liquid hydrogen and says a single launch of polyethylene gives the same 130 days. The same abstract also says that liquid hydrogen is not the best shield per unit mass compared with polyethylene for missions longer than 225 days. |
Corrosion and compatibility
What happens when it meets other materials and environments.
| Environment | Concern | What happens |
|---|---|---|
| Potable water held in spacecraft storage and distribution lines (microbial growth) | moderate | Stored potable water needs a biocide to control microbes, biofilm and microbially influenced corrosion.1 |
| Iodine-disinfected potable water on the International Space Station | low | Iodine must be removed at the dispenser before crew consumption; silver does not need removal.2 |
| # | Environment | Details | Test conditions |
|---|---|---|---|
| 1 | Potable water held in spacecraft storage and distribution lines (microbial growth) | NASA's 2025 ICES paper states that a potable-water biocide should prevent or control microbial growth, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. The target dose is 200 to 400 parts per billion of silver ion (Ag+), chosen with the Spacecraft Water Exposure Guidelines for 1000-day missions as the upper limit. | biocide silver ion (Ag+)target range 200 to 400 ppb Ag+basis upper limit set by the Spacecraft Water Exposure Guidelines for 1000-day missions |
| 2 | Iodine-disinfected potable water on the International Space Station | NASA's 2025 ICES paper states that, unlike iodine, silver ion biocide does not need to be removed at the potable water dispenser, and that Ag+ is effective at levels below 400 ppb that are safe for human consumption. The 2023 ICES paper compares iodine and silver for ISS potable water and identifies gaps in knowledge. | biocide molecular iodine (ISS) versus silver ion (Ag+) |
Risks and side effects
Hazards to people, what happens when a cell overheats, and how the material is handled and stored.
For people
Water is not classified as hazardous in the PubChem record: 1,866 of 1,876 company reports (99.5%) say it does not meet GHS hazard criteria.
- The liquid
- PubChem's health-hazard section says that water itself is nontoxic. Hazards come from substances dissolved in it, which have their own records.
- Biological growth
- Stored water needs a biocide to control microbes, biofilm and microbially influenced corrosion, according to NASA's 2025 ICES paper.
If water freezes in a shield or line
Freezing is a physical hazard for stored water. No source read here tests what it does to a tank.
- Expansion
- PubChem notes that water expands on freezing. Its ice density is 0.917 g/cm3 at 0 °C, while liquid water is 0.999868 g/cm3 at 0 °C/4 °C.
- Damage
- Damage to tanks or lines from freezing is an inference from the expansion note. No test in the sources read here measured it.
Handling and storage
- Biocide
- NASA's 2025 ICES paper targets 200 to 400 ppb of silver ion (Ag+) for stored potable water, and states that Ag+ is effective below 400 ppb and safe for human consumption at that level.
- Iodine
- Unlike silver, iodine must be removed at the potable water dispenser before crew consumption, according to the same 2025 paper.
Test details
The original wording and numbers from the sources, for readers who want them.
Failure risks
| Failure | Trigger and consequence |
|---|---|
| Freezing of stored watermoderate severity | Temperature at or below 0 °CPubChem notes that water expands on freezing; its ice density is 0.917 g/cm3 at 0 °C. Damage to tanks or lines is not measured in any source read here. |
| Microbial growth in stored potable watermoderate severity | Storage without an effective biocideNASA's 2025 ICES paper lists microbial growth, biofilm and microbially influenced corrosion as what a potable-water biocide must prevent. |
Side effects on surrounding parts
| Affects | Effect |
|---|---|
| Crew drinking water at the dispenser | NASA's 2025 ICES paper notes that, unlike silver, iodine must be removed at the potable water dispenser before crew consumption. |
Handling and storage
- Keep stored potable water treated with a biocide; NASA's 2025 requirements call for control of microbes and biofilm.
- Keep stored water from freezing, because it expands when it freezes (PubChem).
Mitigations
- Silver ion biocide is targeted at 200 to 400 ppb; unlike iodine, silver needs no removal at the dispenser.
Supply and geography
How common the raw materials are and where they come from.
Water (H2O), abundance on Earth
About 1,386 million km3 (332.5 million mi3) of water on Earth; the oceans hold about 96.5% of it (USGS). Of freshwater, over 68% is in ice and glaciers, and about 30% is in the ground (USGS).
- Recycling
- Not found in any source we hold.
Documents
Datasheets, safety data sheets, papers and standards you can open.
Full record
The complete spore, as stored. Free to reuse under CC-BY-4.0. Images keep the licence shown with each one.
Show the full YAML
spore: profile
id: water
spore_version: 0.2
family: water
name: Water
abbreviation: H2O
role: hydrogen-rich radiation shield and potable fluid
category: shielding
type: water-and-ice
summary: |
Liquid water has a density of 999.79 kg/m3 at 0.028556 °C in the NIST saturation table, and it holds 4.2198 J/(g*K) of heat capacity at the same point. Water is 11.19% hydrogen by mass (calculated from NIST atomic weights). A 2013 NASA Langley analysis found that a single heavy-lift launch of water could protect astronauts for a 130-day deep-space mission before the 150 mSv design limit was exceeded, under the 1977 galactic cosmic ray environment. That result is an analysis, not a flight test. Water is also the potable water that the International Space Station stores and treats with biocides.
best_for: Hydrogen-rich shielding for crew areas that already hold potable water (NASA Langley analysis, 2013; ISS potable water practice, ICES 2023)
weakest_at: 'Freezing: water expands on freezing (PubChem), and stored water needs a biocide to stay free of microbes and biofilm (NASA ICES 2025)'
identity:
formula: H2O
cas: 7732-18-5
source: pubchem-water
where: Names and Identifiers (CID 962, CAS 7732-18-5); molecular formula H2O from the PubChem compound record
tags:
environments:
- deep-space
stresses:
- total-radiation-dose
applications:
- radiation-shielding
- habitats-and-suits
properties:
- benchmark: density
label: Density of saturated liquid water near 0 °C
value: 999.79
unit: kg/m3
scope: material
conditions:
state: saturated liquid
temperature: 0.028556 °C (first printed row of the saturation table)
pressure: 0.00061248 MPa (saturation pressure as printed)
method: Value copied from the NIST Chemistry WebBook saturation table
status: ground
source: nist-sat
where: Saturation properties table, row 1, Density (kg/m3) column
- benchmark: density
label: Density of liquid water at 0 °C/4 °C, PubChem
value: 0.999868
unit: g/cm3
scope: material
conditions:
state: liquid
basis: printed as 0.999868 at 0 °C/4 °C (liquid)
method: Experimental density value printed in the PubChem record
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Density entry
- benchmark: density
label: Density of liquid water at 25 °C, PubChem
value: 0.995
unit: g/cm3
scope: material
conditions:
state: liquid
temperature: 25 °C
method: Experimental density value printed in the PubChem record
status: ground
note: The 25 °C figure was not checked against a second source. It is lower than the NIST value near 0 °C, and the two temperatures differ, so they are not compared directly.
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Density entry (first value)
- benchmark: density
label: Density of ice at 0 °C
value: 0.917
unit: g/cm3
scope: material
conditions:
phase: ice
temperature: 0 °C
method: Experimental density value printed in the PubChem record
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Density entry (ice value)
- benchmark: melting_point
label: Melting point of ice and water
value: 0
unit: °C
scope: material
conditions:
pressure: not stated in the source
method: Value printed in the PubChem experimental melting point entry
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Melting Point
- benchmark: boiling_point
label: Boiling point, PubChem
value: 99.974
unit: °C
scope: material
conditions:
pressure: not stated for this value; the same PubChem record gives 212 °F at 760 mmHg
method: Value printed in the PubChem experimental boiling point entry
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Boiling Point
- benchmark: boiling_point
label: Boiling point, NIST average
value: 373.17
unit: K
scope: material
conditions:
pressure: not stated on the page
uncertainty: ±0.04 K, average of 7 values
method: Value printed in the NIST phase change data
status: ground
note: NIST gives 373.17 K, which is about 0.05 °C above the PubChem value of 99.974 °C. Both are kept as printed.
source: nist-webbook
where: Phase change data, Tboil
- benchmark: critical_temperature
label: Critical temperature, NIST average
value: 647
unit: K
scope: material
conditions:
uncertainty: ±2 K, average of 7 values
method: Value printed in the NIST phase change data
status: ground
source: nist-webbook
where: Phase change data, Tc
- benchmark: critical_temperature
label: Critical temperature, PubChem
value: 374.2
unit: °C
scope: material
conditions:
basis: printed in the PubChem safety and hazard properties section
method: Value printed in the PubChem record
status: ground
note: The PubChem value of 374.2 °C differs from the NIST value of 647 K (about 373.9 °C). Both are kept as printed.
source: pubchem-water
where: Safety and Hazards, Safety and Hazard Properties, Critical Temperature and Pressure
- benchmark: critical_pressure
label: Critical pressure, NIST
value: 220.64
unit: bar
scope: material
conditions:
basis: NIST gives the value from Sato, Watanabe et al. (1991); other sources in the NIST table list 220.60, 220.46 and 220.64 bar
method: Value printed in the NIST phase change data
status: ground
source: nist-webbook
where: Phase change data, Pc
- benchmark: critical_pressure
label: Critical pressure, PubChem
value: 218
unit: atm
scope: material
conditions:
basis: printed in the PubChem safety and hazard properties section
method: Value printed in the PubChem record
status: ground
note: The PubChem value of 218 atm differs from the NIST value of 220.64 bar (about 217.8 atm). Both are kept as printed.
source: pubchem-water
where: Safety and Hazards, Safety and Hazard Properties, Critical Temperature and Pressure
- benchmark: specific_heat
label: Isobaric heat capacity of saturated liquid water near 0 °C
value: 4.2198
unit: J/(g*K)
scope: material
conditions:
state: saturated liquid
temperature: 0.028556 °C (first printed row)
pressure: saturation
method: Value copied from the NIST saturation table, Cp column
status: ground
source: nist-sat
where: Saturation properties table, row 1, Cp (J/g*K) column
- benchmark: dynamic_viscosity
label: Dynamic viscosity of saturated liquid water near 0 °C
value: 1790.2
unit: uPa*s
scope: material
conditions:
state: saturated liquid
temperature: 0.028556 °C (first printed row)
method: Value copied from the NIST saturation table, Viscosity column
status: ground
note: Snake-case name; this property is not in spores/property-canon.yaml.
source: nist-sat
where: Saturation properties table, row 1, Viscosity (uPa*s) column
- benchmark: surface_tension
label: Surface tension of water at 25 °C
value: 71.97
unit: dyne/cm
scope: material
conditions:
temperature: 25 °C
method: Value printed in the PubChem experimental surface tension entry
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Surface Tension
- benchmark: vapor_pressure
label: Vapor pressure of water at 273.16 K
value: 611.657
unit: Pa
scope: material
conditions:
temperature: 273.16 K
method: Value printed in the PubChem experimental vapor pressure entry
status: ground
note: Snake-case name; this property is not in spores/property-canon.yaml.
source: pubchem-water
where: 'Chemical and Physical Properties, Experimental Properties, Vapor Pressure (VP: 611.657 Pa at 273.16 K)'
- benchmark: refractive_index
label: Refractive index of water
value: 1.333
unit: '-'
scope: material
conditions:
temperature: not stated in the source
wavelength: not stated in the source
method: Value printed in the PubChem refractive index entry
status: ground
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Refractive Index
- benchmark: temperature_of_max_density
label: Temperature of maximum density of liquid water
value: 3.98
unit: °C
scope: material
conditions:
basis: printed as the temperature of maximum density in the PubChem density entry
method: Value printed in the PubChem record
status: ground
note: Snake-case name; this property is not in spores/property-canon.yaml.
source: pubchem-water
where: Chemical and Physical Properties, Experimental Properties, Density entry (Temp of max density 3.98 °C)
- benchmark: hydrogen_mass_fraction
label: Hydrogen share of the mass of water
value: 11.19
unit: '%'
scope: material
conditions:
basis: 2 hydrogen atoms in H2O divided by the molecular weight 18.015 g/mol, with hydrogen taken as 1.008 g/mol
method: 'Calculated by Space Mushroom: 2 x 1.008 / 18.015 = 11.19%. The NIST atomic weight of hydrogen is printed as the interval [1.007 84, 1.008 11], which gives the same 11.19% to two decimals.'
status: calculated
note: Snake-case name; this property is not in spores/property-canon.yaml.
source: nist-atomic
where: Standard atomic weight table, H row (interval printed); PubChem molecular weight 18.015 g/mol
- benchmark: protection_time
label: Protection time from a single heavy-lift launch of water
value: 130
unit: days
scope: material
conditions:
environment: 1977 galactic cosmic ray environment
exposure_limit: 150 mSv design basis
launch: single heavy-lift launch of pure shielding mass, under the paper's assumptions
method: Analysis result stated in the paper abstract; not a measurement
status: calculated
note: Snake-case name; this property is not in spores/property-canon.yaml. The same abstract gives 160 days for liquid hydrogen and says a single launch of polyethylene gives the same 130 days. The same abstract also says that liquid hydrogen is not the best shield per unit mass compared with polyethylene for missions longer than 225 days.
source: singleterry2013
where: Abstract
corrosion:
- environment: Potable water held in spacecraft storage and distribution lines (microbial growth)
headline: Stored potable water needs a biocide to control microbes, biofilm and microbially influenced corrosion.
effect: NASA's 2025 ICES paper states that a potable-water biocide should prevent or control microbial growth, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. The target dose is 200 to 400 parts per billion of silver ion (Ag+), chosen with the Spacecraft Water Exposure Guidelines for 1000-day missions as the upper limit.
rating: moderate
conditions:
biocide: silver ion (Ag+)
target_range: 200 to 400 ppb Ag+
basis: upper limit set by the Spacecraft Water Exposure Guidelines for 1000-day missions
source: irwin2025
where: Introduction, requirements paragraph; Silver biocide section, target range paragraph
- environment: Iodine-disinfected potable water on the International Space Station
headline: Iodine must be removed at the dispenser before crew consumption; silver does not need removal.
effect: NASA's 2025 ICES paper states that, unlike iodine, silver ion biocide does not need to be removed at the potable water dispenser, and that Ag+ is effective at levels below 400 ppb that are safe for human consumption. The 2023 ICES paper compares iodine and silver for ISS potable water and identifies gaps in knowledge.
rating: low
conditions:
biocide: molecular iodine (ISS) versus silver ion (Ag+)
source: irwin2025
where: Silver biocide introduction paragraph
uses:
- application: radiation-shielding
device: Deep-space crew shielding (analysis only)
example: A NASA Langley analysis found that a single heavy-lift launch of water or polyethylene could protect astronauts for a 130-day mission before exceeding the 150 mSv design basis exposure, under the 1977 galactic cosmic ray environment.
source: singleterry2013
where: Abstract
- application: radiation-shielding
device: Deep-space vehicle with permanent on-board water storage (modelling thesis)
example: A 2018 Cal Poly master's thesis on utilizing permanent on-board water storage for deep-space radiation shielding concludes that the permanent inclusion of water gives added support against galactic cosmic rays and solar particle events; the abstract gives no numbers.
source: gehrke2018
where: Abstract (title and conclusion)
- application: habitats-and-suits
device: International Space Station potable water system (drinking, hygiene and technical water)
example: Molecular iodine and ionic silver have been used on the International Space Station for decades to control microbes in potable water, and the 2023 ICES paper compares the two biocides for drinking, hygiene, technical, oxygen-generation and extravehicular activity water.
source: muirhead2023
where: Abstract
supply:
- subject: Water (H2O), abundance on Earth
abundance: About 1,386 million km3 (332.5 million mi3) of water on Earth; the oceans hold about 96.5% of it (USGS). Of freshwater, over 68% is in ice and glaciers, and about 30% is in the ground (USGS).
producers: []
critical_lists: []
recycling: Not found in any source we hold.
substitutes: []
source: usgs-water
where: 'How much water is there on Earth: Overview; Where is Earth''s water located; data table (percent of freshwater)'
documents:
- title: 'NIST Chemistry WebBook: water, saturation and phase change data'
type: database
url: https://webbook.nist.gov/cgi/cbook.cgi?ID=C7732185&Units=SI&Mask=4#Thermo-Phase
year: 2026
- title: 'NIST Chemistry WebBook: water, saturation properties table'
type: database
url: https://webbook.nist.gov/cgi/fluid.cgi?ID=C7732185&Type=SatT&Digits=5&PLow=&PHigh=&PInc=&T=25&RefState=DEF&TUnit=C&PUnit=MPa&DUnit=kg%2Fm3&HUnit=kJ%2Fkg&WUnit=m%2Fs&VisUnit=uPa*s&STUnit=N%2Fm&Action=Load
year: 2026
- title: 'NIST atomic weights: hydrogen and oxygen'
type: database
url: https://physics.nist.gov/cgi-bin/Compositions/stand_alone.pl?ele=H&all=all&ascii=html&isotype=some
year: 2026
- title: 'PubChem: Water (CID 962)'
type: database
url: https://pubchem.ncbi.nlm.nih.gov/compound/Water
year: 2026
- title: Singleterry, Radiation Engineering Analysis of Shielding Materials (NASA Langley; Acta Astronautica 91, 2013)
type: paper
url: https://ntrs.nasa.gov/citations/20140003150
year: 2013
- title: 'Irwin et al., Silver Foam: Long-Term Passive Dosing of Biocide, Update 2025 (ICES-2025-194)'
type: paper
url: https://ntrs.nasa.gov/api/citations/20250005545/downloads/ICES-2025-194.pdf
year: 2025
- title: Muirhead et al., Evaluation of Iodine and Silver as Biocides for Potable Water (ICES 2023)
type: paper
url: https://ntrs.nasa.gov/api/citations/20220015620/downloads/ICES%202023%20Abstract%20Iodine%20and%20Silver%20for%20Strives.pdf
year: 2023
- title: Gehrke, Utilizing Permanent On-Board Water Storage for Efficient Deep Space Radiation Shielding (Cal Poly thesis)
type: paper
url: https://digitalcommons.calpoly.edu/theses/1933
year: 2018
- title: 'USGS Water Science School: How much water is there on Earth?'
type: report
url: https://www.usgs.gov/special-topics/water-science-school/science/how-much-water-there-earth
year: 2026
gaps:
- No flight or space-environment measurement of water as a radiation shield was found in the sources read here. The 130-day figure is an analysis result from one 2013 paper, and only its abstract was read.
- No neutron or galactic cosmic ray dose per unit areal density for water was read from a page. The NIST table covers photons (X-ray and gamma) only.
- The Cal Poly thesis PDF returned HTTP 403 when downloaded, so only its abstract was read. Its Orion-related modelling numbers are not in this profile.
- 'Supply: water is not a mined commodity. No producer shares, critical-mineral listing or recycling figure for water was found in a source we hold; the USGS mineral chapters do not cover it.'
- No room-temperature (20 to 25 °C) liquid density, heat capacity or viscosity from NIST was read. The fetched NIST saturation table printed its first saturated-liquid row at 0.028556 °C, and the 25 °C value was not in the copy we read.
- NIST liquid thermal conductivity in the saturation table (0.55565 W/(m*K) in row 1) was left out because no second source for it was read in this run.
- Ice properties beyond density (heat of fusion, thermal conductivity, expansion coefficient) were not read from a source.
- Critical temperature and pressure disagree between NIST and PubChem; both are kept as printed, and neither was checked against a third source.
- Biocide depletion over the storage life of stored water was not read on a fetched page and is not stated here.
- Freezing damage to tanks or lines has no test result in any source read here; the damage risk is an inference from the PubChem note that water expands on freezing.
- Hazard data rest on the PubChem record (aggregated ECHA notifications). No supplier safety data sheet for water was read.
- 'Snake-case names used for properties not in spores/property-canon.yaml: dynamic_viscosity, vapor_pressure, temperature_of_max_density, hydrogen_mass_fraction, protection_time, critical_temperature and critical_pressure (the last two may already be aliases; check before import).'
- No media, images or CSV added in this profile.
sources:
nist-sat:
title: 'NIST Chemistry WebBook, water: saturation properties table'
id: NIST SRD 69; CAS 7732-18-5
url: https://webbook.nist.gov/cgi/fluid.cgi?ID=C7732185&Type=SatT&Digits=5&PLow=&PHigh=&PInc=&T=25&RefState=DEF&TUnit=C&PUnit=MPa&DUnit=kg%2Fm3&HUnit=kJ%2Fkg&WUnit=m%2Fs&VisUnit=uPa*s&STUnit=N%2Fm&Action=Load
year: 2026
kind: database
license: US government work (NIST)
nist-webbook:
title: 'NIST Chemistry WebBook, water: phase change data'
id: NIST SRD 69; CAS 7732-18-5
url: https://webbook.nist.gov/cgi/cbook.cgi?ID=C7732185&Units=SI&Mask=4#Thermo-Phase
year: 2026
kind: database
license: US government work (NIST)
nist-atomic:
title: 'Atomic weights and isotopic compositions: hydrogen and oxygen (NIST)'
id: NIST standard atomic weights
url: https://physics.nist.gov/cgi-bin/Compositions/stand_alone.pl?ele=H&all=all&ascii=html&isotype=some
year: 2026
kind: database
license: US government work (NIST)
pubchem-water:
title: 'PubChem compound record: Water (CID 962)'
id: CID 962; CAS 7732-18-5
url: https://pubchem.ncbi.nlm.nih.gov/compound/Water
year: 2026
kind: database
license: public domain (NCBI)
usgs-water:
title: 'USGS Water Science School: How much water is there on Earth?'
id: USGS Water Science School
url: https://www.usgs.gov/special-topics/water-science-school/science/how-much-water-there-earth
year: 2026
kind: web
license: public domain (USGS)
singleterry2013:
title: Radiation Engineering Analysis of Shielding Materials to Assess Their Ability to Protect Astronauts in Deep Space From Energetic Particle Radiation
id: NTRS 20140003150; doi:10.1016/j.actaastro.2013.04.013 (Acta Astronautica 91)
url: https://ntrs.nasa.gov/citations/20140003150
year: 2013
kind: paper
license: public domain (NASA)
irwin2025:
title: 'Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems, Update 2025 (ICES-2025-194)'
id: ICES-2025-194; NTRS 20250005545
url: https://ntrs.nasa.gov/api/citations/20250005545/downloads/ICES-2025-194.pdf
year: 2025
kind: paper
license: public domain (NASA)
muirhead2023:
title: Evaluation of Iodine and Silver as Biocides for Potable Water in Human Missions beyond Low Earth Orbit (ICES 2023)
id: NTRS 20220015620
url: https://ntrs.nasa.gov/api/citations/20220015620/downloads/ICES%202023%20Abstract%20Iodine%20and%20Silver%20for%20Strives.pdf
year: 2023
kind: paper
license: public domain (NASA)
gehrke2018:
title: Utilizing Permanent On-Board Water Storage for Efficient Deep Space Radiation Shielding
id: Cal Poly master's thesis, 2018 (Nathan Ryan Gehrke); abstract read
url: https://digitalcommons.calpoly.edu/theses/1933
year: 2018
kind: paper
license: thesis (Cal Poly digital commons)
license: CC-BY-4.0
updated: '2026-11-01'
review:
status: draft
method: assistant
checked_values: 19
unreachable: 12
caveats: 3
note: Written by an AI assistant on 2026-11-01 from NIST, PubChem, USGS and NASA pages read in that run. The Cal Poly thesis PDF was not readable (HTTP 403); its abstract was read. verify-values run on 2026-11-01, 7 values found in the source text, 12 not checkable by the verifier (their pages were not readable by it; those values were read by hand in this run), 0 not found.
risks:
hazards:
- text: PubChem reports that water does not meet GHS hazard criteria in 1,866 of 1,876 company reports (99.5%); the record's aggregated ECHA notifications give the same picture.
source: pubchem-water
where: Safety and Hazards, GHS Classification (note line)
- text: PubChem's health-hazard section states that water itself is nontoxic; hazards come from substances dissolved in it.
source: pubchem-water
where: Safety and Hazards, Hazards Identification, Health Hazards
failure_risks:
- mode: Freezing of stored water
trigger: Temperature at or below 0 °C
consequence: PubChem notes that water expands on freezing; its ice density is 0.917 g/cm3 at 0 °C. Damage to tanks or lines is not measured in any source read here.
severity: moderate
source: pubchem-water
where: Chemical and Physical Properties, Density entry
- mode: Microbial growth in stored potable water
trigger: Storage without an effective biocide
consequence: NASA's 2025 ICES paper lists microbial growth, biofilm and microbially influenced corrosion as what a potable-water biocide must prevent.
severity: moderate
source: irwin2025
where: Introduction, requirements paragraph
side_effects:
- text: NASA's 2025 ICES paper notes that, unlike silver, iodine must be removed at the potable water dispenser before crew consumption.
affects: Crew drinking water at the dispenser
source: irwin2025
where: Silver biocide introduction paragraph
handling:
- text: Keep stored potable water treated with a biocide; NASA's 2025 requirements call for control of microbes and biofilm.
source: irwin2025
where: Introduction, requirements paragraph
- text: Keep stored water from freezing, because it expands when it freezes (PubChem).
source: pubchem-water
where: Chemical and Physical Properties, Density entry
mitigations:
- text: Silver ion biocide is targeted at 200 to 400 ppb; unlike iodine, silver needs no removal at the dispenser.
source: irwin2025
where: Silver biocide section, target range paragraph
story:
recipe:
line: 'Water is H2O: one oxygen atom bonded covalently to two hydrogen atoms (PubChem, CAS 7732-18-5). Its molecular weight is 18.015 g/mol (PubChem). Water is not mined; it is the liquid that the shield and the potable water system store.'
parts:
- name: Hydrogen
symbol: H
role: Two hydrogen atoms per molecule. Hydrogen makes up 11.19% of the mass of water (calculated; see properties). NIST prints the standard atomic weight of hydrogen as an interval, so no single value is given here.
- name: Oxygen
symbol: O
role: One oxygen atom per molecule; the rest of the mass of water. NIST prints the standard atomic weight of oxygen as an interval, so no single value is given here.
risk_groups:
- title: For people
level: 0
verdict: Not classified hazardous
lead: 'Water is not classified as hazardous in the PubChem record: 1,866 of 1,876 company reports (99.5%) say it does not meet GHS hazard criteria.'
points:
- label: The liquid
line: PubChem's health-hazard section says that water itself is nontoxic. Hazards come from substances dissolved in it, which have their own records.
- label: Biological growth
line: Stored water needs a biocide to control microbes, biofilm and microbially influenced corrosion, according to NASA's 2025 ICES paper.
- title: If water freezes in a shield or line
lead: Freezing is a physical hazard for stored water. No source read here tests what it does to a tank.
points:
- label: Expansion
line: PubChem notes that water expands on freezing. Its ice density is 0.917 g/cm3 at 0 °C, while liquid water is 0.999868 g/cm3 at 0 °C/4 °C.
- label: Damage
line: Damage to tanks or lines from freezing is an inference from the expansion note. No test in the sources read here measured it.
- title: Handling and storage
points:
- label: Biocide
line: NASA's 2025 ICES paper targets 200 to 400 ppb of silver ion (Ag+) for stored potable water, and states that Ag+ is effective below 400 ppb and safe for human consumption at that level.
- label: Iodine
line: Unlike silver, iodine must be removed at the potable water dispenser before crew consumption, according to the same 2025 paper.
why: Water is a hydrogen-rich material that the International Space Station already stores as potable water (ICES 2023). A 2013 NASA Langley analysis found that a single heavy-lift launch of water could protect astronauts for a 130-day deep-space mission under its assumptions, the same as polyethylene. A 2018 Cal Poly thesis concludes that permanent on-board water storage adds protection against galactic cosmic rays and solar particle events; its abstract gives no numbers. The shielding figures are analysis results, not flight measurements.
uses:
- where: Deep-space crew shielding (analysis)
line: A NASA Langley analysis found that a single heavy-lift launch of water could protect astronauts for a 130-day mission before the 150 mSv design basis was exceeded, under the 1977 galactic cosmic ray environment.
- where: Potable water on the International Space Station
line: Iodine and silver biocides have been used on the International Space Station to control microbes in potable water. A 2023 ICES paper compares them for drinking, hygiene, technical, oxygen-generation and extravehicular activity water.
can_do:
- label: Radiation shielding
benchmark: protection_time
value: 130 days
line: A single heavy-lift launch of water can protect astronauts for a 130-day mission under the 1977 galactic cosmic ray environment, before the 150 mSv design basis is exceeded (NASA Langley analysis, 2013).
- label: Heat capacity
benchmark: specific_heat
value: 4.2198 J/(g*K)
line: Saturated liquid water has an isobaric heat capacity of 4.2198 J/(g*K) at 0.028556 °C, per the NIST saturation table.
- label: Liquid range at 1 atm
value: 0 °C to 99.974 °C
line: Liquid water runs from its melting point of 0 °C to its boiling point of 99.974 °C, as printed by PubChem; the record gives the boiling point without its pressure, and the same record gives 212 °F at 760 mmHg.
compare: Per launch, the 2013 NASA Langley analysis finds that water and polyethylene protect astronauts for the same 130-day mission under its assumptions. The same abstract gives 160 days for liquid hydrogen and says that liquid hydrogen is not the best shield per unit mass compared with polyethylene for missions longer than 225 days. These are analysis results for the 1977 galactic cosmic ray environment, not measurements. The NIST table gives only the photon (X-ray and gamma) attenuation of water, so it does not show how water compares for galactic cosmic rays.
compare_rows:
- label: Density, liquid near 0 °C
benchmark: density
- label: Hydrogen mass fraction
benchmark: hydrogen_mass_fraction
handling:
- Keep stored potable water treated with a biocide; NASA's 2025 requirements call for control of microbes and biofilm.
- Keep water from freezing in a shield or line, because it expands when it freezes (PubChem).
- Silver ion biocide is targeted at 200 to 400 ppb; unlike iodine, silver needs no removal at the dispenser (ICES 2025).
good_for:
- Hydrogen-rich shielding in crew areas where potable water is already stored (NASA Langley, 2013; ICES 2023).
- 'A well-characterised heat capacity: 4.2198 J/(g*K) for saturated liquid near 0 °C (NIST).'
watch_out:
- 'Freezing: water expands when it freezes (PubChem), and no source read here tests what that does to a tank.'
- 'Biological growth: stored water needs a biocide (NASA ICES 2025).'
- The 130-day protection figure is a 2013 analysis under stated assumptions, not a flight test.
verdict: Water is a practical hydrogen-rich shield for crew areas that already hold potable water. Its shielding value rests on a 2013 analysis, not on a flight test, and it must be kept from freezing and from microbes.
References
Every number above carries a reference number. Click one to see the source and where in it the value comes from.
| # | Source | Type | Year | Used for |
|---|---|---|---|---|
| NIST Chemistry WebBook, water: saturation properties table | database | 2026 | 3 values | |
| NIST Chemistry WebBook, water: phase change data | database | 2026 | 3 values | |
| Atomic weights and isotopic compositions: hydrogen and oxygen (NIST) | database | 2026 | 1 value | |
| PubChem compound record: Water (CID 962) | database | 2026 | 16 values | |
| USGS Water Science School: How much water is there on Earth? | web | 2026 | 1 value | |
| Radiation Engineering Analysis of Shielding Materials to Assess Their Ability to Protect Astronauts in Deep Space From Energetic Particle Radiation | paper | 2013 | 2 values | |
| Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems, Update 2025 (ICES-2025-194) | paper | 2025 | 6 values | |
| Evaluation of Iodine and Silver as Biocides for Potable Water in Human Missions beyond Low Earth Orbit (ICES 2023) | paper | 2023 | 1 value | |
| Utilizing Permanent On-Board Water Storage for Efficient Deep Space Radiation Shielding | paper | 2018 | 1 value |
Updated